background image

HAWK 8000 CONTROLLER – INSTALLATION & COMMISSIONING INSTRUCTIONS 

 

11 

EN1Z-1016GE51 R0218 

ORDER NUMBERS 

Table 3. Licensed controllers, incl. 1 year of SW update 

OS number 

description 

CLNXHAWK8-100 

HAWK8 NO WIFI 100 PTS 1YR SW UPDATE 

CLNXHAWK8-250 

HAWK8 NO WIFI 250 PTS 1YR SW UPDATE 

CLNXHAWK8-500 

HAWK8 NO WIFI 500 PTS 1YR SW UPDATE 

CLNXHAWK8-1250 

HAWK8 NO WIFI 1250 PTS 1YR SW UPDATE 

CLNXHAWK8-5K 

HAWK8 NO WIFI 5K PTS 1YR SW UPDATE 

CLNXHAWK8-10K 

HAWK8 NO WIFI 10K PTS 1YR SW UPDATE 

CLNXHAWK8W02-100  HAWK8 WIFI ZONE2 100 PTS 1YR SW UPDATE 
CLNXHAWK8W02-250  HAWK8 WIFI ZONE2 250 PTS 1YR SW UPDATE 
CLNXHAWK8W02-500  HAWK8 WIFI ZONE2 500 PTS 1YR SW UPDATE 
CLNXHAWK8W02-1250  HAWK8 WIFI ZONE2 1250 PTS 1YR SW UPD. 
CLNXHAWK8W02-5K 

HAWK8 WIFI ZONE2 5K PTS 1YR SW UPDATE 

CLNXHAWK8W02-10K  HAWK8 WIFI ZONE2 10K PTS 1YR SW UPDATE 

 

Table 4. Expansion Modules 

OS number 

description 

HON-NXEM-LON 

LON EXPANSION MODULE SINGLE PORT 

HON-NXEM-2X485 

RS385 EXP. MODULE DUAL PORT 

HON-NXEM-232 

RS232 EXP. MODULE SINGLE PORT 

 

Table 5. Hardware-only controllers, for replacement 

OS number 

description 

CLNXSERIES8 

HAWK8 NO WIFI W/O LICENSE 

CLNXSERIES8W02 

HAWK8 WITH WIFI ZONE 2 W/O LICENSE 

 

Table 6. Spare parts 

OS number 

description 

CLNXHAWK8-CLIP 

HAWK8 CENTRALINE CLIP 

CLNXHAWK8-SD 

HAWK8 SD CARD 

HON-NX8-KIT 

WIFI-A RS485 + POWER TERMINALS 

 

Table 7. Point upgrade licenses 

OS number 

description 

CLNX-DEVICE-UP-10 

HAWK8 PLUS 500 POINTS UPGRADE 

CLNX-DEVICE-UP-25 

HAWK8 PLUS 1250 POINTS UPGRADE 

CLNX-DEVICE-UP-50 

HAWK8 PLUS 2500 POINTS UPGRADE 

 

Table 8. Software upgrade licenses 

OS number 

description 

CLNX-SMA-8005-1YR 

HAWK8 1YR SW UPDATE 250-499 PTS 

CLNX-SMA-8005-3YR 

HAWK8 3YR SW UPDATE 250-499 PTS 

CLNX-SMA-8005-5YR 

HAWK8 5YR SW UPDATE 250-499 PTS 

CLNX-SMA-8010-1YR 

HAWK8 1YR SW UPDATE 500-1249 PTS 

CLNX-SMA-8010-3YR 

HAWK8 3YR SW UPDATE 500-1249 PTS 

CLNX-SMA-8010-5YR 

HAWK8 5YR SW UPDATE 500-1249 PTS 

CLNX-SMA-8025-1YR 

HAWK8 1YR SW UPDATE 1250-4999 PTS 

CLNX-SMA-8025-3YR 

HAWK8 3YR SW UPDATE 1250-4999 PTS 

CLNX-SMA-8025-5YR 

HAWK8 5YR SW UPDATE 1250-4999 PTS 

CLNX-SMA-8100-1YR 

HAWK8 1YR SW UPDATE 5000-9999 PTS 

CLNX-SMA-8100-3YR 

HAWK8 3YR SW UPDATE 5000-9999 PTS 

CLNX-SMA-8100-5YR 

HAWK8 5YR SW UPDATE 5000-9999 PTS 

CLNX-SMA-8200-1YR 

HAWK8 1YR SW UPDATE 10000+ PTS 

CLNX-SMA-8200-3YR 

HAWK8 3YR SW UPDATE 10000+ PTS 

CLNX-SMA-8200-5YR 

HAWK8 5YR SW UPDATE 10000+ PTS 

 

Table 9. Miscellaneous licenses 

OS number 

description 

CLNX-JACE-8000-AX 

HAWK8 ENABLER FOR NIAGARA AX 

CLNXHAWK8-DEMO 

HAWK8 Demo License 

 

Table 10. Optional drivers 

OS number 

description 

CLNX-DR-SMS-ALM 

NX SMS DRIVER 

CLNX-DR-MFID 

NX FIDELIO DRIVER 

 

DRIVERS 

Included Drivers 

▪  Niagara NX drivers 

-  BACnet IP 
-  BACnet MS/TP 
-  FOX ("inter-station" communication, i.e. to a 

supervisor or other HAWK controllers) 

-  KNX-IP 
-  LON 
-  M-Bus 
-  Modbus, all types 
-  oBIX 
-  Open ADR 
-  SNMP 

▪  CentraLine-specific drivers 

-  Panel Bus 
-  C-Bus 
-  LON IO 
-  Print-Out 
-  IO Creation 
-  Bacnet Util 
-  Extensions 
-  EnOcean 

 

Optional Drivers 

▪  Niagara NX drivers 

-  SMS (see also Table 10 above) 
-  Fidelio (see also Table 10 above) 

▪  CentraLine-specific drivers (under preparation) 

-  Application Library 
-  Energy Vision 

 

Содержание Centra Line CLNXHAW-5K

Страница 1: ...uded in Shipment 2 Overview of Features 3 Materials and Tools Required 4 Preparation 4 Mounting 4 Environmental Requirements 4 Dimensions Tab Mounting 4 Mounting on a DIN Rail 5 Wiring 5 Bus and Port Connections 6 Order Numbers 11 Drivers 11 Included Drivers 11 Optional Drivers 11 Specifications 12 Power 12 Environmental Specifications 12 Approvals Certifications etc 12 Related Technical Literatur...

Страница 2: ...ety are invalidated Rules regarding electrostatic discharge should be followed Use only accessory equipment which comes from or has been approved by Honeywell Construction The HAWK 8000 Controller is an independently mounted electronic control unit with fixed wiring Mounting Method The HAWK 8000 Controller is suitable for mounting as follows in cabinets in fuse boxes conforming with standard DIN43...

Страница 3: ...DC 50 60HZ 24W MAX OPERATING TEMPERATURE 20C to 60C REQ USE OF CLASS 2 24VAC TRANSFORMER OR EQUIVALENT 12977 8 Fig 1 HAWK 8000 overview of features 1 Earth ground 6 PRI primary LAN1 10 100 Mbit Ethernet connection 2 Terminal block for 24 VAC DC power supply 7 SEC secondary LAN2 10 100 Mbit Ethernet connection 3 RS485 A port and bias termination switch 8 Access shutter for microSD card slide to ope...

Страница 4: ...ecial system password stored in the controller base software If you swap in a card from a previously configured unit you must re enter this same password using a serial connection to the controller s Debug port WARNING Risk of electric shock or equipment damage Disconnect the power supply before removing or inserting the microSD flash memory card Failure to do so is likely to damage the equipment ...

Страница 5: ...ination 6 Carefully secure both ends of the final assembly with DIN rail end clips provided by the DIN rail vendor Wiring WARNING Risk of electric shock or equipment damage Before making power terminations de energize the 24V power source Do not restore power until completing all other mounting and wiring See also section Power Up and Initial Checkout on pg 8 Wiring Earth Ground and Power Earth gr...

Страница 6: ...ition WiFi adapter is disabled ACC Left position Controller provides operation as a WiFi access point for up to 20 clients CLT Right position Controller operates as a client to an existing 802 11a b g n router or access point To use either screw in the antenna directly see Fig 9 or use an optional coax cable extension kit CBL WIFI EXT to locate the antenna up to 2 m away An associated LED remains ...

Страница 7: ... baud and uses a 3 position screw terminal connector A A S RS485 A HAWK 8000 RS485 B DEVICE 1 DEVICE 1 DEVICE 2 DEVICE 2 DEVICE N DEVICE N B B S S S S S S S Fig 10 RS485 wiring example NOTE RS485 devices on the same network should use the same communication protocol and the same baud rate Up to 32 or more devices may be supported depending upon device specifications Use shielded twisted pair 18 22...

Страница 8: ...predictable behavior if other electrically non isolated devices are connected and the potential difference is too high In the case of the installation of HAWK 8000 con trollers in already existent RS485 two wire systems e g when replacing PANTHER or LION controllers with HAWK 8000 controllers not using a separate signal ground wire will probably have no undesirable effects The cable length affects...

Страница 9: ...at boot up also occurs during other critical operations such as a firmware upgrade to the controller and or any attached modules To be safe do not remove power from the controller while its BEAT LED is flashing in a 90 10 ON OFF duty cycle Instead wait for the normal 50 50 flash to return before removing power If the BEAT LED remains ON constantly does not light up or flashes very fast contact T A...

Страница 10: ...s door opened Legend 1 BACKUP button and corresponding BACKUP LED 2 PROG USB 2 0 for use with USB flash thumb drive 3 DEBUG Micro A USB for serial debugging communications 4 SHT DWN Recessed pushbutton for initiating a controlled shutdown The DEBUG port is a standard Micro A type USB port for serial debugging communications to the controller You can use a serial terminal program for example PuTTY ...

Страница 11: ...5 HAWK8 PLUS 1250 POINTS UPGRADE CLNX DEVICE UP 50 HAWK8 PLUS 2500 POINTS UPGRADE Table 8 Software upgrade licenses OS number description CLNX SMA 8005 1YR HAWK8 1YR SW UPDATE 250 499 PTS CLNX SMA 8005 3YR HAWK8 3YR SW UPDATE 250 499 PTS CLNX SMA 8005 5YR HAWK8 5YR SW UPDATE 250 499 PTS CLNX SMA 8010 1YR HAWK8 1YR SW UPDATE 500 1249 PTS CLNX SMA 8010 3YR HAWK8 3YR SW UPDATE 500 1249 PTS CLNX SMA 8...

Страница 12: ... MTTF 10 years Dimensions See Fig 3 to Fig 5 APPROVALS CERTIFICATIONS ETC UL 916 Energy Management Equipment Edition 4 CE 2014 53 EU RED 2011 65 EU RoHs FCC Part 15 Subpart B Class B Part 15 Subpart C C UL listed to Canadian Standards Assoc CSA C22 2 No 205 M1983 Signal Equipment Ethernet IEEEC 802 3 Purpose of the device is multifunctional non safety control intended for HVAC in home residential ...