Honeywell CAMIR Скачать руководство пользователя страница 3

CAMIR: PIR Sensor with Camera - Installation Instructions (ENGLISH)

 

 

1. Introduction

 

This volumetric sensor uses passive infra-red technology. The CAMIR 
sensor is part of the range of radio peripherals used with the Domonial 
800++ control panels.

 

Special Instructions for Installing with Pets

 

To take full advantage of the pet immunity in the CAMIR sensor, follow 
the guidelines below:

 

•  Set the sensor to the Low or lowest sensitivity setting as required 

by the application.

 

•  At the Lowest sensitivity setting, the total combined weight of 

animals may not exceed 36 kg (80 lb).

 

•  At Low sensitivity setting, the total combined weight of animals 

may not exceed 18 kg (40 lb).

 

•  Mount the sensor where pets cannot come within 1.80 m  

(6 feet) of the sensor by climbing on furniture, boxes  
or other objects.

 

•  Do not aim the sensor at stairways or furniture/objects that can be 

climbed on by animals.

 

•  Environmental differences and the amount of heat radiated by an 

animal will vary the animal immunity levels exhibited by the sensor.

 

Sensor must have a clear line-of-sight to protected area. (cf figure 
1 for mounting location recommendations)

 

Each installation should be tested to determine the exact level of 
animal immunity attainable.

 

 

2. Mounting

 

Tamper Switches

 

The CAMIR sensor is equipped with a normally-closed cover tamper. 
This tamper opens when the cover is opened.

 

Two wall tampers are provided:

 

•  Operational when the sensor is fixed flat against a wall.

 

•  On one angle, operational when the sensor is fixed at an angle (cf 

Figure 4). 

Mounting Instructions

 

• 

Using a small screwdriver, push in the housing latch at the bottom 
of the sensor and gently remove the front cover, lifting it from the 
bottom.

 

•  Hold the batteries in place, and pull out the battery tab to power up 

the sensor. You can register the sensor immediately or at a later 
time.

 

•  Mount the rear housing flat against a wall or in a corner 

using screws placed in the mouting holes (cf Figure 4).

 

 

3. LED operation

 

Use the configuration tool to enable the alarm LED (cf Figure 5).

 

 

4. Registration

 

Registration on a Domonial panel

 

Registration is the procedure that associates the detector with the 
control panel. This operation requires a programming tool based on 
PDA or PC, or the TCU keypad. The complete procedure is described 
in the user manuals of these tools.

 

•  Connect the programming tool to the control panel and 

enter  programming mode.

 

•  Select the item 

Add New Device

.

 

•  Remove the battery tab or activate the tamper by opening and 

closing the cover of the sensor. A confirmation message appears 
after several seconds, indicating the registration of the sensor 
at the control panel, together with the radio signal level and the 
serial number of the device.

 

•  Choose the function mode, the label, etc.

 

 

Warning: The sensor must always be registered in its 

final position with a minimum radio signal level of 4/10 

5. Configuration

 

The CAMIR sensor is configured using a programming tool (PC). 
The following settings can be configured:

 

• The 

LED

 

• PIR 

sensitivity

 

Setting Sensitivity and Testing the Sensor

 

Set the sensitivity appropriate for the application (see the options 
below), and replace the cover. Begin the walk-test as soon as the 
LED stops blinking. Walk through the detection zone(s), observing 
the sensor’s LED. The LED indicates detection of movement and 
transmission of an alarm.

 

 

The absolute range of a sensor unit is subject to variation due to 
different clothing types, backgrounds and ambient temperature. 
For this reason, you should ensure that the most likely intruder 
routes are well within the sensor’s detection zones, and that walk-
testing is carried out along those routes.

 

Sensitivity Options 

• 

Lowest Sensitivity: 3-5 steps. This is the recommended setting for 
applications with pets up to 36 kg.

 

•  Low Sensitivity: 2-4 steps. This is the recommended setting for 

applications with pets up to18 kg.

 

•  Medium Sensitivity. 1-3 steps.

 

•  High Sensitivity: 1-2 steps. This is the recommended setting for 

any location where an intruder is expected to cross only a small 
portion of the area covered. Recommended for High Security 
applications (Conforms to EN50131).

 

 

Note: The distances in the detection pattern illustrations are only 
given as a guide, and do not represent the maximum detection 
distances

 

 

6. Walk-Test Mode 

After the warm-up period (2 min 30 sec), when the cover is closed 
(operation of the tamper switch) the product enters into test mode for 
10 minutes. This test is mandatory to ensure proper detection. Each 
detection results in an alarm signal being sent. To restart the 10-
minute test period, operate the tamper switch by opening and closing 
the cover. Immediately after entering test mode, you can take photos 
with the programming tool upon operation of the tamper (providing 
there is no battery fault) - cf figure 7.

 

 

7. Battery Failure 

The sensor signals a battery failure at the control panel when the 
battery needs to be replaced. The sensor will continue to operate for 
up to one month after this, but the photo functionality will be disabled.

 

Note: that if the batteries are weak, the photo function of the sensor 
will not work. 

 

Battery Removal & Handling Safety Warning: Risk of 
fire, explosion and burns. Do not recharge, disassemble, 
heat above 100° C, or incinerate the battery. Use care when 
changing the battery to ensure that the battery is not damaged 
and the terminals are not shorted during removal. If the battery 
is damaged, use personal protective equipment to remove it 
immediately, and dispose of it in a safe manner (refer to the 
battery manufacturers specifications). Comply with applicable 
national and local regulations to dispose of depleted batteries. 
For Switzerland, Annex 4.10 of SR 814.013 applies to the battery 
included with this product. 

 

 

For all enquiries, please visit your local Honeywell website.

 

 

 

 

 

 

 

 

 

- 2 - 

Содержание CAMIR

Страница 1: ...supplied Alimentation requise 2 piles lithium de type AA fournies Tamper Switches Cover Opening Wall Wrenching off wall Autoprotection Capot ouverture Mur arrachement Sensitivity Selectable Lowest Low Medium and High Sensibilité au choix très basse basse moyenne et haute White light immunity 6 500 Lux min Insensibilité à la lumière blanche 6 500 Lux min Note In EN 50131 2 2 compliant installations...

Страница 2: ...MINE NO LED AUCUN LED MESSAGE Preparing to take a picture Préparation à la prise de photo Picture is going to be taken Photo va être prise Picture is taken Photo est prise Restart no test Relancer aucun test CT WT Lw Lower 18 20 Lw Faible portée18 20 IM Intermediate 12 17 IM Portée Intermediaire 12 17 L Long 1 11 L Longue portée 1 11 CT Corner Tamper Autoprotection d angle Lw IM L 18 20 12 17 1 11...

Страница 3: ...d in its final position with a minimum radio signal level of 4 10 5 Configuration The CAMIR sensor is configured using a programming tool PC The following settings can be configured The LED PIR sensitivity Setting Sensitivity and Testing the Sensor Set the sensitivity appropriate for the application see the options below and replace the cover Begin the walk test as soon as the LED stops blinking W...

Страница 4: ... Avertissement lors de son enregistrement le détecteur doit toujours être dans sa position définitive avec un niveau radio minimum de 4 10 5 Configuration La configuration du détecteur CAMIR s effectue à l aide d un outil de programmation PC clavier TCU Il est possible de configurer les éléments suivants LED et Sensibilité PIR Définition de la sensibilité et test du détecteur Ajuster la sensibilit...

Отзывы: