CHAPTER
3
Maintenance
Clean the Detector
Clean the detector using a soft cloth with a water-based or non-alcoholic cleaner. Other types of
cleaners, solvents, and lubricants can contaminate and cause permanent damage to the detector
sensors.
Charge the Battery
You can charge the battery via an IntelliDox docking module, the charger adaptor & USB Charger,
and the Cradle Charger.
Note:
The Li-ion battery may require 5 hours to full capacity. The time needed to charge will increase if
the Detector is activated. The detector may be warm during charging; this is normal. To preserve
the life of the battery, deactivate the Detector when not in use.
The battery operating temperature is -40°C to +60°C.
WARNING
The Honeywell BW™ Flex Series uses a Li-ion battery that may present a risk of fire or chemical
burn hazard if misused. Do not disassemble, heat above 100°C, or incinerate.
CAUTION
l
To avoid personal injury and property damage, adhere to the following:
l
Charge the battery immediately when the Detector emits a low battery alarm.
l
Charge the battery in a safe area that is free of hazardous gas in a temperature range from 0-
45°C.
l
Charge the battery using Honeywell charger adapters designed for this Detector only. Do not
use any other charger adapters. Failure to adhere to this caution can lead to fire and explosion.