Enter Output No.
R02 02
Output Number
01-16 = VISTA-20P output no.; 01-08 = VISTA-15P output no.; 17-18 = on-board triggers
Enter the device output number (programmed in *79 Menu Mode) you want associated with
this output. Press [
✱
] to continue.
02 A E P TRIG
R02 1 1 3 ZL=00
Summary Screen
A summary screen appears showing the programmed settings.
Press [
✱
] to continue.
About Zone Lists (*81 Menu Mode)
Zone lists let you group individual zones for use with certain system actions. The following table shows
the available zone lists and their purposes:
List No.
Used for…
Notes
1, 2
general purpose (GP)
3 chime-by-zone
(see field *26 to enable option)
4
cross zones (see note at right)
5
night stay zones
6
general purpose
V20PSIA/V15PSIA
: dial delay disable
7 general
purpose
V20PSIA/V15PSIA
: unlimited reports
8 general
purpose
9
zones that activate Pager 1
10
zones that activate Pager 2
11
zones that activate Pager 3 (VISTA-20P)
12
zones that activate Pager 4 (VISTA-20P)
•
Any list may include any or all of the system's zone
numbers.
•
A zone list can be assigned to more than one output relay.
•
Zone List 4: When creating zone list 4 for cross zoning,
include only zones assigned to zone types 3, 4, or 5. Do not
include zones that have delays (entry/exit zones, interior
w/delay) or 24-hour zones, as these zone types may produce
unpredictable operation and may not function as intended.
See field *85 for Cross Zone Timer option.
•
Zone List 6:
V20PSIA/V15PSIA
:
See field *50 for Dial Delay
Disable option.
•
Zone List 7:
V20PSIA/V15PSIA
:
See field *93 for Unlimited
Reports option.
Zone List Programming
1. Select an appropriate zone list number.
2. Add the desired zone numbers to be included in that list.
Start Zone List Program Mode by pressing
✱
81 while in Data Programming mode.
*81 Menu Mode
Zone List No.
(00 = Quit)
01
Zone List Number
01-12 = zone list number; [
∗
] to continue
Enter the Zone List Number to program (or 00 to quit). Press [
✱
] to advance.
In the following displays, zone list 01 has been selected for programming.
01 Enter Zn Num.
(00 = Quit)
00
Zone Number
01-64† = zone numbers followed by [
∗
] to accept each zone; 00 to continue
Enter each zone number to add to the zone list, followed by pressing [
✱
] (example, 01
✱
,
02
✱
, 03
✱
). After all zones are entered, press 00 to continue.
IMPORTANT:
Do not include fire zones in zone lists that are used to STOP device actions.
† VISTA-20P = 01-64; VISTA-15P = 01-06, 09-34, 49-56.
01 Del Zn List?
0 = No 1 = Yes
0
Deleting Zone Lists
0 = don’t delete list; 1 = delete this zone list; [
∗
] to continue
To delete the zone list, enter 1. All zones in the zone list will be deleted automatically and
the system returns to the Zone List No. prompt.
To save the zone list, enter 0.
01 Delete Zone?
0 = No 1 = Yes
0
Deleting a Zone
0 = don’t delete zones; 1 = go to next prompt to delete zones; [
∗
] to continue
To save the zone list, enter 0 and the system returns to the Zone List No. prompt.
To delete a zone or zones in a zone list, enter 1 to continue.
01 Zn to Delete?
(00 = Quit)
00
Delete the Zone
01-64† = zones to be deleted from list followed by [
∗
] to accept each zone; 00 to continue
Enter each zone to be deleted from the list, followed by [
✱
]. After all zones to be deleted are
entered, enter 00 to return to the Zone List No. prompt so that another list can be
programmed, if desired.
† VISTA-20P = 01-64; VISTA-15P = 01-06, 09-34, 49-56.
Installation and Setup Guide
5-12
Содержание ADEMCO VISTA-15PSIA
Страница 36: ...Installation and Setup Guide 4 12 ...
Страница 62: ...Installation and Setup Guide 6 8 ...
Страница 71: ...Notes 9 3 ...
Страница 72: ...Notes Installation and Setup Guide 9 4 ...
Страница 73: ...Notes 9 5 ...
Страница 74: ...Notes Installation and Setup Guide 9 6 ...