Interactive Mode Programming (
∗∗∗∗
56, *57,
∗∗∗∗
58,
∗∗∗∗
79,
∗∗∗∗
80,
∗∗∗∗
81,
∗∗∗∗
82)
Entering Interactive Mode
Press [
∗
] + [Interactive Mode No.] (for example,
∗
56) while in Program Mode. The Alpha
display keypad will display the first of a series of prompts.
After making the appropriate entry, press the [
∗
] key to accept the entry and continue to
the next prompt.
Loading Factory Defaults/Initializing for Download
To Load Default Entries
Press
∗
97 while in Program Mode. This resets all data fields to the default values shown
on the Program Form. Use
∗
97 only if you wish to return to the original factory-
programmed defaults.
To Initialize Download ID
Press
∗
96 while in Program Mode. This initializes the system for downloading and resets
all the subscriber account numbers and CSID.
Do not press
✱
97 to load defaults if any programming has been done previously—data
already programmed into the system will be changed!
Exiting the Programming Mode
Prevent installer code
reentry
Press
∗
98. Exits Programming Mode and prevents re-entry by:
Installer Code + [8] + [0] + [0]. To enter the programming mode if
∗
98 was used to exit,
you must first power the system down. Then power up again, and press [
∗
] and [#] at the
same time, within 50 seconds of powering up.
See field *88 for other Program mode lockout options.
Allow installer code
reentry
Press
∗
99. Exits Programming Mode and allows re-entry by:
Installer Code + [ 8] + [0] + [0] or by: Pressing [
∗
] and [#] at the same time, within 50
seconds of power-up.
Zone Type Definitions
Zone types define the way in which the system responds to faults in each zone.
Zone Type
Description
Type 00
Zone Not Used
Program a zone with this zone type if the zone is not used.
Type 01
Entry/Exit
Burglary #1
•
Assign to zones that are used for primary entry and exit.
•
Provides entry delay when zone is faulted if control is armed in the Away, Stay, or Night-Stay
modes.
•
No entry delay provided when the panel is armed in the Instant/Maximum mode.
•
Entry delay #1 is programmable for each partition (field *35).
•
Exit delay begins whenever the control is armed, regardless of the arming mode selected, and
is programmable (field
✱
34).
Type 02
Entry/Exit
Burglary #2
•
Assign to zones that are used for entry and exit and require more time than the primary
entry/exit point.
•
Provides a secondary entry delay, in same manner as entry delay #1.
•
Entry delay #2 is programmable for each partition (field *36).
•
Exit delay is same as described for Type 01.
Type 03
Perimeter
Burglary
•
Assign to all sensors or contacts on exterior doors and windows.
•
Provides an instant alarm if the zone is faulted when the panel is armed in the Away, Stay,
Night-Stay, Instant or Maximum modes.
Type 04
Interior Follower
•
Assign to a zone covering an area such as a foyer, lobby, or hallway through which one must
pass upon entry (to and from the keypad).
•
Provides a delayed alarm (using the programmed entry 1 time) if the entry/exit zone is faulted
first. Otherwise this zone type gives an instant alarm.
•
Active when the panel is armed in the Away mode.
•
Bypassed automatically when the panel is armed in the Stay or Instant modes;
if armed in Night-Stay mode, zones assigned to zone list 05 (night-stay zone list) are not
bypassed when system armed in Night-Stay mode.
Installation and Setup Guide
3-2
Содержание ADEMCO VISTA-15PSIA
Страница 36: ...Installation and Setup Guide 4 12 ...
Страница 62: ...Installation and Setup Guide 6 8 ...
Страница 71: ...Notes 9 3 ...
Страница 72: ...Notes Installation and Setup Guide 9 4 ...
Страница 73: ...Notes 9 5 ...
Страница 74: ...Notes Installation and Setup Guide 9 6 ...