background image

 

 

ADEMCO VISTA SERIES 

VISTA-20P / VISTA-20PSIA 
VISTA-15P / VISTA-15PSIA 

Security Systems 

 

 

 

 

Installation and Setup Guide 

 

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

K5305-1V5   10/04   Rev. A      

Содержание ADEMCO VISTA-15PSIA

Страница 1: ...ADEMCO VISTA SERIES VISTA 20P VISTA 20PSIA VISTA 15P VISTA 15PSIA Security Systems Installation and Setup Guide K5305 1V5 10 04 Rev A ...

Страница 2: ...the hallway outside may not wake up the sleeper if the door is closed DINING KITCHEN BEDROOM BEDROOM BEDROOM BEDROOM LIVING ROOM BEDROOM BDRM BDRM DINING LIVING ROOM TV ROOM KITCHEN BEDROOM BEDROOM TO BR LVNG RM BASEMENT KTCHN CLOSED DOOR GARAGE Smoke Detectors for Minimum Protection Smoke Detectors for Additional Protection Heat Activated Detectors floor_plan 001 V0 Install a smoke detector insid...

Страница 3: ...re Zones 2 6 Double Balanced Zones 2 6 Zone Doubling 2 6 Smoke Detectors 2 6 Smoke Detector Notes 2 7 4219 4229 Expansion Zones 2 7 Installing the RF Receiver and Wireless Transmitter Zones 2 8 Compatible Receivers 2 8 Receiver Connections 2 8 RF Receiver Notes 2 8 Installing a 5800TM Module 2 9 Installing the Transmitters 2 9 Transmitter Battery Life 2 9 Installing a Keyswitch 2 10 Keyswitch Conn...

Страница 4: ...10 About Zone Lists 81 Menu Mode 5 12 Zone List Programming 5 12 About Function Keys 57 Menu Mode 5 13 Programming Function Keys 5 13 About Descriptor Programming 82 Menu Mode 5 14 Programming Zone Descriptors Menu Mode 82 5 14 Adding Custom Words will not be annunciated by 4285 4286 Phone Module 5 15 Programming Installer and User Schedules 5 17 System Communication and Operation 6 1 Panel Commun...

Страница 5: ...nes zones 9 24 using up to 2 4219 4229 modules Up to 26 wireless transmitter zones 5800 series zones 9 34 Up to 2 configurable zone types Security Codes Up to 48 Security Codes with separate authority levels and partition access Up to 32 Security Codes with separate authority levels One button arming Dedicated keys can arm the system Dedicated keys can arm the system Schedules Up to 32 can control...

Страница 6: ... pulses for fire Uses current limiting circuitry for protection Auxiliary Power Output See note See note 12VDC 600 mA maximum uses fuse for protection Backup Battery See note See note Rechargeable sealed lead acid type 12VDC 4AH minimum Long Range Radio See note See note Primary telephone number messages can be reported via ECP connection to various Long Range Radios check compatibility availabili...

Страница 7: ...b Swing the base of the board into the mounting clips and secure the board to the cabinet with the accompanying screws see Detail B CIRCUIT BOARD DETAIL B SIDE VIEW OF MOUNTING CLIPS DETAIL A SIDE VIEW OF BOARD SUPPORTING SLOTS CIRCUIT BOARD MOUNTING 001 V0 CABINET CABINET Figure 2 Mounting the PC Board Mounting Board with RF Receiver Do not mount the cabinet on or near metal objects This will dec...

Страница 8: ...r that particular unit s current draw Values are for standby alarm alarm for keypads means armed with backlighting on and sounder on In UL installations maximum current draw from the Auxiliary Output and the Alarm Output combined must not exceed 600 mA 500 mA max from Aux Output Values are for relays OFF relays ON CALIFORNIA STATE FIRE MARSHALL CSFM AND UL RESIDENTIAL FIRE 24 HOUR BATTERY BACKUP R...

Страница 9: ...s Battery Connections batt_conn 001 V0 CONNECT FLYING LEADS AFTER AC POWER IS APPLIED BLACK RED 1 Place the 12 volt backup battery in the cabinet 2 After all connections to the control are completed and AC power has been applied connect the red and black flying leads on the control board to the battery Do not attach these leads to the battery terminals until all connections are completed UL For UL...

Страница 10: ...RVE POLARITY Figure 5 Sounder Wiring Supervised Connecting the Keypads and Other Addressable Devices Connections conn 001 V0 RED GREEN YELLOW BLACK AR MED RE AD Y 4_ 5 6 IN 7 OUT Connect keypads and other addressable devices 4204 4219 4229 4286 5881 LRR etc to the control s keypad terminals as shown on the Summary of Connections diagram The system supports up to 8 keypads which can be assigned to ...

Страница 11: ...he current draw of that device alone The length of all wire runs for both partitions combined must not exceed 1500 feet 457m when unshielded quad conductor cable is used 750 feet if shielded cable is used This restriction is due to the capacitive effect on the data lines when quad cable is used Table of Device Addresses This Device Uses Address Reports as Enabled By RF Receiver 00 100 56 zone prog...

Страница 12: ...s terminals but does not increase the total number of zones supported by the control If enabled Zone Programming mode Hardwire Type prompt option 3 hardwire zones are automatically paired as shown in the table Connect as shown below resistors provided Do not use zone doubling for fire zones NOTE A short across the EOL i e at terminal on either zone of a zone doubled pair or on a double balanced zo...

Страница 13: ...UTPUT TERMINALS 5 4 _ _ _ BLK _ 4_wiresmk 007 V0 TO ZONE TERM TO ZONE TERM RELAY CONTACT OPENS MOMENTARILY UPON FIRE ALARM RESET PROGRAM RELAY AS ZONE TYPE 54 FIRE ZONE RESET 4 WIRE SMOKE OR COMBUSTION DETECTOR N C N O Figure 9a 4 Wire Smoke Detector Using Relay for Power Reset 2000 OHMS EOLR HEAT DETECTOR RED VIOLET AUX PWR 5 _ _ BLK _ 4_wiresmk 008 V0 4 WIRE SMOKE OR COMBUSTION DETECTOR _ TO ZON...

Страница 14: ...tenna mounting etc MOUNTING HOLES INTERFERENCE INDICATOR LED CIRCUIT BOARD DIP SWITCH ANTENNAS INSERT IN RIGHT HAND TERMINALS YELLOW RED BLACK GREEN WIRING OPENING KNOCKOUT AREA FOR SURFACE WIRING TO CONTROL S REMOTE KEYPAD CONNECTION POINTS 5882 LOCATION TO RELEASE CIRCUIT BOARD REMOVE SCREWS AND BEND BACK TABS NOTE CIRCUIT BOARD IS MOUNTED IN CONTROL S CABINET GROUNDING LUGS 2 PROVIDED MUST BE I...

Страница 15: ... provided with the device Use 56 or 58 Zone Programming Menu modes to program zone information and enroll transmitters VISTA 20P zones 9 48 buttons 49 64 VISTA 15P zones 9 34 buttons 49 56 Wireless Keys Use Wireless Key Programming Templates section of the 58 Zone Programming Menu mode to program zone information and enroll each button of the wireless keys used Once a wireless key is enrolled it m...

Страница 16: ...ABLE 8 PIN TRIGGER CONNECTOR KEY 12 AUX OUTPUT 17 OUTPUT 18 RED YELLOW GREEN RED BLACK Figure 12 Keyswitch Wiring Connections Keyswitch Notes UL A UL Listed keyswitch is required for fire installations and UL commercial and residential burglar alarm installations The Ademco 4146 keyswitch is UL Listed If a keyswitch is used on an installation that transmits opening and closing signals the keyswitc...

Страница 17: ...f field 199 set for 2 digit display where xx is the module s address If communication tamper failure occurs on a device with zones wired to it all zones on the device will be displayed in their respective partitions Powerline Carrier Devices UL Powerline Carrier devices and the 1361X10 Transformer are not UL Listed for fire or burglary functions and are intended for home automation 1 Install the p...

Страница 18: ...r Trigger Use Only 1361X10 Transformer Trigger outputs are normally high and go low upon programmed condition The outputs can be programmed for inverted operation normally low go high using 79 Menu mode Program these triggers using 80 81 Menu modes as you would for any other relay output When using these outputs note pin 1 output number 17 trigger 1 15 ohms to ground when closed output low open wh...

Страница 19: ...4 RING PHONE OUTPUT 5 NO CONNECTION 6 7 AUDIO OUT 4286 ONLY IMPORTANT NOTE FOR EXISTING INSTALLATIONS EXISTING WIRES CONNECTED TO THE HANDSET TERMINALS ON CONTROL MUST BE MOVED FROM THERE TO TERMINALS 3 AND 4 ON THE 4285 4286 NOTE IF THE TELEPHONE HAS BUILT IN CALLER ID THE CALLER ID FUNCTION MAY NOT WORK CA38A IN CANADA 4286_cntrl 001 V0 LOUDER VOLUME 4286 ONLY 21 22 23 24 25 CALLER ID UNIT RJ31X...

Страница 20: ... TRIGGER CONNECTOR OUTPUT 18 EOL RING TIP OPTIONAL MONITORING ZONE CONNECTION USE ZONE TYPE 81 FALLING VOICE TRIG GND 12VDC IN SWITCH BANK 2 SWITCH BANK 1 SWITCH BANK 2 SWITCH BANK 1 AUXILIARY AUDIO LEVEL ADJUSTMENT TRIM POT aav_uvcm 003 V0 CONTROL INCOMING PHONE LINE TO PREMISES HANDSET 5 1 ON 2 ON 3 OFF 4 ON 5 ON 6 ON 7 ON 8 ON 1 OFF 2 OFF 3 OFF 4 OFF 5 OFF 6 OFF 7 OFF 8 ON 23 24 25 12VDC GND 4 ...

Страница 21: ...5 Menu Mode Programming for details on setting devices for manual automatic operation 80 Output Definitions Define up to 48 output definitions which can control the output relays mapped using 79 Output Device Mapping mode 81 Zone List Programming Create Zone Lists for relay powerline carrier zones chime night stay cross zones and pager zones 82 Alpha Programming Create alpha descriptors for easy z...

Страница 22: ...to faults in each zone Zone Type Description Type 00 Zone Not Used Program a zone with this zone type if the zone is not used Type 01 Entry Exit Burglary 1 Assign to zones that are used for primary entry and exit Provides entry delay when zone is faulted if control is armed in the Away Stay or Night Stay modes No entry delay provided when the panel is armed in the Instant Maximum mode Entry delay ...

Страница 23: ... zones assigned to zone list 05 night stay zone list are not bypassed when system armed in Night Stay mode Type 12 Monitor Zone Works as a dynamic monitor of a zone fault trouble not alarm In the case of a short open the message ALARM 24 Hr Non Burg XXX where XXX is the zone number will be sent to the Central Station The system keypad will display a check message indicating the appropriate zone bu...

Страница 24: ...s as follows When the zone is faulted all alarm sounding and dialer reporting stops except for fire alarms which immediately terminate the voice session and cause a fire report to be sent When the zone is restored session ended sounding resumes if bell timeout has not expired and reports that were stopped are sent Types 90 93 Configurable Allows for various custom responses Options include respons...

Страница 25: ...eypad set to the same House ID You can assign RF house ID for each partition 26 Chime By Zone List 3 0 no zone list chimes on fault of any entry exit or perimeter zone when chime mode on 1 use zone list chimes on fault of specific zones programmed in relay zone list 3 when Chime mode on If enabled you can define the specific zones intended to chime when faulted while the system is in Chime mode Us...

Страница 26: ...lways enabled field does not exist 38 Confirmation Of Arming Ding 0 no ding 1 confirmation ding after arming system 2 ding after arming from RF button or RF keypad only Confirmation of arming is 1 2 sec external sounder ding If 1 selected ding occurs when closing report is sent or at the end of Exit Delay If 2 selected ding occurs upon reception of the wireless arming command UL Installations must...

Страница 27: ...0 9 B F 1 SESCOA 0 9 only Select SESCOA or Radionics format Select 0 for all other formats 54 Dynamic Signaling Delay 0 disabled both signals sent 1 15 entry times a 15 second delay e g 1 15 seconds 2 30 seconds etc Intended for use with Long Range Radio reporting This field lets you select the time the panel should wait for acknowledgment from the first reporting destination see 55 before it atte...

Страница 28: ...o result if a fault occurs in an exit or interior zone within 2 minutes following the end of the exit delay and an EXIT ALARM message will be sent to the central station except for V20PSIA V15PSIA see field 69 Recent Closing report With Contact ID format the message will contain the zone number and error code 374 ALARM EXIT ERROR 60 Trouble Report Code 0 no report 1 F see description above 59 Sent...

Страница 29: ...mode to enter output devices powerline carrier devices into the system See Output Device Programming section for procedures 80 Output Programming Menu Mode Use this menu mode to define output functions for use with output devices powerline carrier devices See Output Programming section for procedures 81 Zone List Programming Menu Mode Use the menu mode to define zone lists See Zone List Programmin...

Страница 30: ...entry in field 40 only on alternate dial attempts this allows proper dialing in the event call waiting service is later canceled by the user Exit Delay Restart reset option allows use of the key to restart the exit delay at any time when the system is armed STAY or INSTANT This feature also enables automatic exit delay reset which resets exit delay if the entry exit door is re opened and closed be...

Страница 31: ...lues Pressing 97 resets all data fields to the factory default values shown on the Program Form IMPORTANT Do not press 97 to load defaults if any programming has been done previously data already programmed into the system will be changed 98 Command to Exit Program Mode with installer code lockout Exits Programming Mode and prevents re entry by Installer Code 8 0 0 To enter the programming mode if...

Страница 32: ...rs exit by pressing and next field number To clear entries press 164 165 Pager 2 Report Options See pager 1 reports field 162 for entries except use zone list 10 166 Pager 3 Phone No VISTA 20P Enter up to 20 digits If entering fewer than 20 digits exit by pressing next field number To clear entries press 166 167 Pager 3 Characters VISTA 20P Enter up to 16 characters See field 161 for explanation o...

Страница 33: ...Type Options Auto Restore entry 2 Faults on zones set for this option are cleared restore messages sent upon restoral of faults Vent Zone entry 2 Zones set for this option are ignored if faulted when arming the system but are protected if the zone is later restored e g an open window can be ignored when arming but if the window is later closed it will be protected opening the window again causes a...

Страница 34: ...2 delay 2 0 no 4 use exit delay 0 no 8 yes see note 2 Entry 7 fault display power reset verification Entry 8 entry delay 1 entry delay 2 exit delay interior zone type ENTRY 9 ENTRY 10 Alarm Sounds Use Bell Timeout Respond as Fire Zone Trouble Sounds Chime when Chime Mode On 0 none 1 steady keypad 2 steady bell and keypad 3 pulsing bell and keypad 0 no 4 yes see fields 32 33 0 no 8 yes see zone typ...

Страница 35: ... enter the partition in which the keypad is located for VISTA 15P enter 1 to enable or 0 to disable the keypad Entry 2 Enter the desired sound option for this keypad 191 Keypad 3 Device Address 18 See field 190 for entries and explanation 192 Keypad 4 Device Address 19 See field 190 for entries and explanation 193 Keypad 5 Device Address 20 See field 190 for entries and explanation 194 Keypad 6 De...

Страница 36: ...Installation and Setup Guide 4 12 ...

Страница 37: ...s corrected Faults on the common zone are displayed on common zone keypads and will also appear on another partition s keypad when that partition is armed Either partition can clear and restore the common zone after an alarm About Zone Programming 56 and 58 Menu Modes Used to program zones zone types report codes enroll 5800 RF Wireless Transmitter serial numbers and identify the type of loop inpu...

Страница 38: ... Aux 21 Arm AWAY 02 Entry exit 2 09 Fire 22 Disarm 03 Perimeter 10 Interior w Delay 23 No Alarm Resp 04 Interior Follower 12 Monitor Zone 24 Silent Burglary 05 Day Night 14 Carbon Monoxide 77 Keyswitch 06 24 Hr Silent 16 Fire w Verify 81 AAV Mon Zone 5800 button type transmitters only 90 91 Configurable 10 Partition 1 Partition No P VISTA 20P 1 3 partition 3 common to continue Enter the Partition ...

Страница 39: ... N L A022 4064 1 Serial number Entry and Loop Number Entry to continue Used only when enrolling wireless transmitters a Transmit two open close sequences If using a button type transmitter press and release the button twice but wait about 4 seconds before pressing the button the second time OR b Manually enter the 7 digit serial number printed on the label of the transmitter Then press the key the...

Страница 40: ... 1 Yes and refer to the Alpha Descriptor Programming section for available descriptors ENTER ZN NUM 00 QUIT 11 Next Zone Number to continue 00 quit If 0 No was entered above the system will return you to the ENTER ZN NUM prompt for the next zone When all zones have been programmed enter 00 to quit Completing Zone Programming When you have finished programming all zones test each zone using the sys...

Страница 41: ...g If HW hardwired or AW Auxiliary is entered for Input Device Type the next screen will be similar to the prompt shown except that HW or AW will be displayed under IN If RF BR or UR is entered a prompt for Serial and Loop number will be displayed as follows 10 INPUT S N L AXXX XXX Serial number S N serial number L loop number to continue Manually enter the serial number found on the transmitter la...

Страница 42: ...e in the chart that follows these procedures Select from templates Press to display template 1 shown selected NOTE If necessary press to back up and re enter template number Press if you want to return to 58 Menu mode summary screen L 01 02 03 04 T 23 22 21 23 Template Display When is pressed the selected template will be displayed Top line of display represents loop numbers bottom line represents...

Страница 43: ...0 at the Zone Number prompt NOTE Following the successful enrollment of each wireless device remove ONE of the serial number labels from the device and affix it in the appropriate column on the ZONE PROGRAMMING worksheet of the Programming Form then enter the other information zone number zone type loop number etc relevant to that device Wireless Key Predefined Default Templates YOU MUST PROGRAM T...

Страница 44: ... map output devices using 79 Menu Mode before you can use 80 menu Mode 2 Use 80 Menu Mode to create output definitions which control the output devices if desired 3 Use 81 Zone List Menu mode to define zone lists for use with output devices if the device action is based on more than one zone To program a device for manual activation user code 7 8 2 digit device number or for scheduled automatic ac...

Страница 45: ...DELETE 0 Output Type 0 delete 1 relay on 4204 4229 module 2 Powerline Carrier device X 10 to continue Select whether this is a relay or a Powerline Carrier X 10 device If Powerline Carrier is selected go to A prompt If relay is selected skip to B prompt A XX UNIT No yy Unit Number prompt appears if X 10 is selected 01 16 predefined address to continue Enter the unit code set at the device and pres...

Страница 46: ... same attributes but assign the appropriate output number i e output devices can be assigned more than one function number but each function number can only be assigned a single output number For example if you want to pulse a strobe light upon fire alarms on zone 4 using a relay mapped to output number 2 as programmed in 79 Menu Mode program the following in 80 Menu Mode Prompt Entry Output Funct...

Страница 47: ...ming Away 38 Chime 54 Fire Zone Reset 22 Disarming 39 Any Fire Alarm 58 Duress 31 End of Exit Time 40 Bypassing 60 AAV 32 Start of Entry Time 41 AC Power Failure 66 Function Key 33 Any Burglary Alarm 42 System Battery Low 67 Bell Fail 43 Comm Failure 68 Telco Line Cut 78 Keyswitch Red LED 79 Keyswitch Green LED Use 0 Any for Partition No P entry Or at Disarming whichever occurs earlier Use 57 Menu...

Страница 48: ...one List Programming 1 Select an appropriate zone list number 2 Add the desired zone numbers to be included in that list Start Zone List Program Mode by pressing 81 while in Data Programming mode 81 Menu Mode Zone List No 00 Quit 01 Zone List Number 01 12 zone list number to continue Enter the Zone List Number to program or 00 to quit Press to advance In the following displays zone list 01 has bee...

Страница 49: ... end user macro key or panic key 3 2 1 6 5 4 9 8 7 0 READY INSTANT MAX OFF CODE AWAY TEST CHECK STAY BYPASS A B C D keypad_keys 00 001 V0 Partition 1 Partition Numbe 1 partition 1 2 partition 2 3 common partition to continue Enter the partition in which the function key is active Key A Func Zone 95 00 System defaults to these function key settings Macros 11 12 apply to VISTA 20P only If Night Stay...

Страница 50: ...ber and moves the cursor to the next position for a descriptor 8 Saves the entered descriptor and moves to the next descriptor Start Zone Descriptor Programming mode by pressing 82 while in Data Programming mode Program Alpha 0 No 1 Yes 00 Program Alpha 0 no 1 yes to continue The Program Alpha prompt will appear Press 1 to continue Custom Words 0 No 1 Yes 00 Custom Words 0 no 1 yes to continue The...

Страница 51: ... respectively for example if you are creating the first custom word or word string enter 01 for the second enter 02 etc A cursor will now appear at the beginning of the second line or 11 12 13 for partition 1 partition 2 and common lobby descriptors respectively See Assigning Partition Descriptors paragraph below NOTE Custom words 8 9 and 10 are reminder words that are programmed using Scheduling ...

Страница 52: ...IGHT 162 ROOM 163 ROOF S 164 SAFE 165 SCREEN 166 SENSOR 167 SERVICE 168 SHED 169 SHOCK 170 SHOP 171 SHORT 173 SIDE 174 SKYLIGHT 175 SLIDING 176 SMOKE 178 SONS 179 SOUTH 180 SPRINKLER 182 STATION 184 STORE 185 STORAGE 186 STORY 190 SUPERVISED 191 SUPERVISION 192 SWIMMING 193 SWITCH T 194 TAMPER 196 TELCO 197 TELEPHONE 199 TEMPERATURE 200 THERMOSTAT 201 TOOL 202 TRANSMITTER U 205 UP 206 UPPER 207 UP...

Страница 53: ...at a specified time Events 10 11 are reserved for the installer only Latch key report option 03 is sent to all pagers in the user s partition and is active only when the system is armed message sent is 777 7777 User must be enabled for paging see User Attributes in System Operation section Forced bypass is automatically enabled regardless of setting in field 23 If selected system displays custom w...

Страница 54: ...s schedule e g To make a schedule that happens everyday you would select all days with a repeat count of 1 To make a schedule that runs for one week then stops select everyday with a repeat count of 0 RANDOMIZE 0 NO 1 YES X Randomize For events 01 and 11 0 no 1 yes Press to continue If selected the scheduled start and stop times will vary within 60 minutes of the hour time For example if a schedul...

Страница 55: ...number if programmed to get a valid message through If the panel is not successful after its numerous attempts the keypad displays COMM FAILURE on alpha keypads or FC on fixed word keypads Report Code Formats The following chart indicates the types of handshake kissoff frequencies that the panel supports and the different formats that can be sent with each FORMAT HANDSHAKE TRANSMITS DATA KISSOFF T...

Страница 56: ...SSSRA Ac RARARA RA Ac LoBat Res SSS S RL SSS S RL SSSS RLLB RLRLRL RL LB Trouble Res SSS S RT SSS S RT SSSS RTt RTRTRT RT t Bypass Res SSS S RB SSS S RB SSSS RBb RBRBRB RB b Where SSS or SSSS Subscriber ID C Close Code 1st Digit A Alarm Code 1st digit U User Number in hex Z Typically Zone Number 2nd digit Gg Test Code 1st 2nd digits Tt Trouble Code 1st 2nd digits R Restore Code Alarm Bb Bypass Cod...

Страница 57: ...rm Expansion Module 145 ECP Module cover tamper 146 Silent Burglary 150 Alarm 24 Hour Auxiliary Monitor zone 162 Carbon Monoxide 301 AC Power 302 Low System Battery Battery Test Fail 305 System Reset Log only 309 Battery Test Failure 321 Bell Siren Trouble 333 Trouble Expansion Mod Supervision 341 Trouble ECP Cover Tamper 344 RF Receiver Jam 351 Telco Line Fault 353 Long Range Radio Trouble 373 Fi...

Страница 58: ...ition master authority level 0 User 03 49 V20P 03 33 V15P perform security functions arm disarm etc only cannot add delete users view event log set system clock or program scheduled events 1 Arm Only see user arm system only 2 Guest see user can disarm the system only if it was used to arm the system 3 Duress see user performs security functions but also silently sends a duress message to the cent...

Страница 59: ...see Single Button Arming above If the Auto Stay Arm feature is enabled field 84 and the entry exit door is not opened and closed within the programmed exit delay time the system will automatically arm in STAY mode if armed from a wired keypad non RF device If the door is opened and closed within the exit delay period the system arms in AWAY mode Arming Stay Enter code STAY 3 or simply press approp...

Страница 60: ...s Displayed as Zone A 1 95 B 99 C 3 96 IMPORTANT For a Silent panic function if programmed to be of practical value you must program a report code for the zone and the system must be connected to a central station Setting the Real Time Clock Set the time and date by doing the following 1 6 3 Security Code Alpha Display DISARMED READY TO ARM 2 Press when the time date is displayed A cursor appears ...

Страница 61: ...attery is not replaced within 30 days a CHECK display may occur NOTE Some wireless sensors contain a non replaceable long life battery which requires replacement of the entire unit at the end of battery life e g Nos 5802 5802CP TELCO FAULT 94 Telephone Line Failure indicates that a monitored telephone line if programmed in field 92 has been cut or disconnected Depending on how the system was progr...

Страница 62: ...Installation and Setup Guide 6 8 ...

Страница 63: ...nsmitted with a TEST report The keypad will beep about every 40 seconds as a reminder that the system is in the Test mode NOTE Wireless motion detectors Passive Infrared units will send signals out only if they have been inactive for 3 minutes conserves battery life 3 Test all sensors using the procedure described in the User s Guide Testing the System section 4 After checking sensors turn off the...

Страница 64: ...y entering any user code partition specific OFF Dialer Communication Test and Periodic Test Reports 1 Enter Installer Code 5 TEST then press 1 at the prompt to start the Dialer Test 1 DIAL 0 WALK no special display on Fixed Word keypads The following will be displayed accompanied by 2 beeps if test is successful PHONE OKAY Cd displayed on Fixed Word Display Keypads A Contact ID report will also be...

Страница 65: ... SESCOA 20 pulses sec 1800Hz Data Tone 2300Hz ACK KISSOFF Can report 0 9 B F Ademco Contact ID 10 characters sec DTMF TouchTone Data Tones 1400 2300Hz ACK 1400Hz KISSOFF LINE SEIZE Double Pole RINGER EQUIVALENCE 0 1B FCC REGISTRATION No 5GBUSA 44003 AL E 4 Maximum Zone Resistance Zones 1 8 300 ohms excluding EOLR standard zones Compatible Devices Keypads 6150 Fixed Word Keypad 6160 Alpha Keypad 61...

Страница 66: ...profile Photoelectric w 135 F thermal 2100T Low profile Ionization type direct wire 1100 Transformers 1321 16 5VAC 25VA Plug In Transformer No 1321CN in Canada 1361X10 16 5VAC 40VA Powerline Carrier device Interface AC Transformer Sounders Ademco AB 12M 10 Motorized Bell Box Ademco 1011BE12M 10 Motorized Bell Box Ademco 702 Outdoor Siren Ademco 719 2 Channel Siren Ademco 747 Indoor Siren Ademco 74...

Страница 67: ...ations 5802MN 5802MN2 5804 5804BD 5814 5816TEMP 5819 5819WHS BRS and 5850 Compatible 5800 Series Transmitters Table Model Product Input Type Description 5801 Wireless Panic Transmitter UR or RF Four pushbuttons each with a unique input loop code Programmable responses e g Panic Arm Disarm etc 5802 Pendant Personal Emergency Transmitter BR Only Has single pushbutton Usually programmed for response ...

Страница 68: ...loop codes Loop 1 Built in shock sensor loop wired to TB1 normally closed Loop 2 For a closed circuit contact loop using the built in reed switch in conjunction with a magnet Loop 3 Externally wired closed circuit loop connected to TB2 5827 Wireless Keypad Uses House ID only Can be used to turn the burglary protection on and off Features the same built in panic functions as wired keypads The keypa...

Страница 69: ... to make such connections themselves but should contact appropriate electric inspection authority or electrician as appropriate Ringer Equivalence Number Notice The Ringer Equivalence Number REN assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface The termination on an interface may consist of any combination of...

Страница 70: ...nded downloading is not permissible for UL installations 11 Auto disarming is not a UL Listed feature Notes for SIA Installations 1 As SIA limits for delay of alarm reporting and sounding can exceed UL limits for commercial and residential applications the following UL requirements per UL681 are provided The maximum time that a control unit shall be programmed to delay the transmission of a signal...

Страница 71: ...Notes 9 3 ...

Страница 72: ...Notes Installation and Setup Guide 9 4 ...

Страница 73: ...Notes 9 5 ...

Страница 74: ...Notes Installation and Setup Guide 9 6 ...

Страница 75: ...aping gas improper storage of flammable materials overloaded electrical circuits children playing with matches or arson Depending on the nature of the fire and or location of the smoke detectors the detector even if it operates as anticipated may not provide sufficient warning to allow all occupants to escape in time to prevent injury or death Passive Infrared Motion Detectors can only detect intr...

Страница 76: ...tors such as humidity high or low temperatures as well as large swings in temperature may all reduce the actual battery life in a given installation This wireless system however can identify a true low battery situation thus allowing time to arrange a change of battery to maintain protection for that given point within the system Installing an alarm system may make the owner eligible for a lower i...

Страница 77: ... 3 1 4 1 4 11 5 8 6 7 Device number 5 2 Dialer Communication Test 7 2 DIP Switches 2 9 Disarm 3 3 Disarming 5 11 6 5 Double Balanced 2 6 E Enrolling 2 9 5 1 entering serial number 5 5 Entry Delay 3 3 4 4 4 9 6 6 6 7 Entry Delay 02 4 2 Entry Exit Burglary 3 2 Entry Exit Burglary EOLR 2 6 8 1 Event Logging 4 6 Exit Delay 4 2 4 4 4 6 4 9 6 6 6 7 Exit Error Alarm 3 Exit Error Alarm 6 7 Exit Error Repo...

Страница 78: ...entary Power 2 4 Swinger Suppression 4 7 System Communication 4 9 5 2 6 1 System Operation 5 6 5 7 5 11 5 2 System Status Report Codes 4 4 System Test 7 1 T tamper switch 2 10 9 2 Telco Line 2 13 3 Telephone Line Monitoring 1 1 Test Mode 7 1 7 2 Test Restore Report Code 4 5 Touch Screen Device AUI Enable 4 9 touchpads 4 4 Transmitter Input Types 5 3 Trigger outputs 2 12 Trouble by Day 3 3 Trouble ...

Страница 79: ...ENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION COMPLIES WITH FCC RULES PART 68 FCC REGISTRATION NO 5GBUSA 44003 AL E RINGER EQUIVALENCE 0 1B WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM IN ADDITION THIS SYSTEM MUST BE CHECKED BY A QUALIFIED TECHNICIAN AT LEAST ONCE EVERY THREE 3 YEARS CAN BE USED FOR 2 ...

Страница 80: ...ON ON THE FACE HEREOF IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Seller does not represent that the product s it sells may not be compromised or circumvented that the pro...