OUTPUT SELECTION SWITCH SETTINGS 

8-Position DIP switch SW1 is used to select Voice/Siren 
outputs as well as bell/ringback and trigger options 

 

1.  Voice/Siren Outputs:  SW1 Switches 1 - 4 

 

Fire 
Output 

Burg 
Output 

CO 
Output 

DIP Setting 

1* 

English English English 

2

3

4

5

6

1

ON

7

8

2* 

English/ 
French 

English/ 
French 

English/ 
French 

2

3

4

5

6

1

ON

7

8

 

3* 

English/ 
Spanish 

English/ 
Spanish 

English/ 
Spanish 

2

3

4

5

6

1

ON

7

8

 

4* 

Eng/Span/ 
French 

Eng/Span/ 
French 

Eng/Span/ 
French 

2

3

4

5

6

1

ON

7

8

 

5* 

French French French 

2

3

4

5

6

1

ON

7

8

 

6* 

Spanish Spanish Spanish 

2

3

4

5

6

1

ON

7

8

 

Temporal 
Fire 

Sweep 

Temporal 
CO 

2

3

4

5

6

1

ON

7

8

 

English Sweep  English 

2

3

4

5

6

1

ON

7

8

 

English/ 
French 

Sweep 

English/ 
French 

2

3

4

5

6

1

ON

7

8

 

10 

Temporal 
Fire 

Eng/Span/ 
French 

Temporal 
CO 

2

3

4

5

6

1

ON

7

8

 

11 

Temporal 
Fire 

Spanish 

Temporal 
CO 

2

3

4

5

6

1

ON

7

8

 

12 

Temporal 
Fire 

English 

Temporal 
CO 

2

3

4

5

6

1

ON

7

8

 

13 

English/ 
Spanish 

Sweep 

English/ 
Spanish 

2

3

4

5

6

1

ON

7

8

 

14 

Temporal 
Fire 

French 

Temporal 
CO 

2

3

4

5

6

1

ON

7

8

 

15 

Eng/Span/ 
French 

Sweep 

Eng/Span/ 
French 

2

3

4

5

6

1

ON

7

8

 

*  Most Commonly Used Settings 

 
 
 

2.  Bell, Trigger Options:  SW1 Switches 5-8 

SW1 switches 5 through 8 set bell test and trigger 
options as shown. 
 

2

3

4

5

6

1

ON

7

8

BELL TEST/

RINGBACK OPTIONS 

MUST BE ON FOR 

LISTED INSTALLATIONS

BURG/FIRE TRIGGER
ON = POSITIVE (+12V) TRIGGER
OFF = NEGATIVE (0V) TRIGGER

FIRE TRIGGER
ON = POSITIVE (+12V) TRIGGER
OFF = NEGATIVE (0V) TRIGGER

CARBON MONOXIDE TRIGGER  
ON = POSITIVE (+12V) TRIGGER
OFF = NEGATIVE (0V) TRIGGER

745VSD3-005-V0

 

 

Figure 4.  SW1 Switches 5 - 8 

 
NOTE: 
 If Bell Test/Ringback is selected (dip switch 5),  
a fire signal will momentarily generate a warbled siren 
sound for the initial portion of the siren sound and then 
revert to the normal siren sound and voice message.     
 
Configuring Multiple Speakers  
Depending on the installation, 745VSD3 provides 
multiple speaker configurations as shown: 

 

745VSD3-004-V0

2 SPEAKERS

16 OHM

LOAD

4 SPEAKERS
8 OHM LOAD

8

8

8

8

8

8

4

3

4

3

 

Figure 5.  Typical Multiple Speaker Configurations 
 

Fused Method for Providing Battery Power  

For installations requiring more power than the panel 
aux power can provide (such as when using 8- or 16-
ohm speakers) you may need to obtain additional power.   
You may obtain power from an external power supply, or 
through a fused connection directly to the control panel 
backup battery, as shown: 

745x3-002-V0

VOICE
SIREN

DRIVER

  

CONTROL

GROUND

12V (   )

POS

(   )

NEG

(   )

2 AMP

IN-LINE FUSE

BATT

 

Figure 6.  Connecting Power from the System’s Battery 

Содержание ADEMCO 745VSD3

Страница 1: ...PUT Connect to 12VDC source on panel See Fused Method for Providing Battery Power on Page 3 if needed 3 SPKR 4 SPKR SPEAKER TERMINALS Connect 8 16 or 32 ohm 15 watt speaker See Figure 6 for multiple speaker config urations For Listed installations Listed Ademco 705 820 713 or 746 32 speakers must be used 5 F FIRE INPUT Connect the control panel s output designated as the FIRE steady output to this...

Страница 2: ...on Off selection 0 Output Number Select 17 7 Exit the panel s Programming mode 2 ANNUNCIATING CO ALARM ON VISTA 32 128 250 and variants a Hookup If using a VISTA 32 128 250 or other variant that supports CO Zone Response Type 14 Configure 7845VSD3 for a positive 12V trigger by setting DIP Switch 8 to ON On the panel configure a relay output 4204 4101SN to alert on Zone Response Type 14 Connect 745...

Страница 3: ...tches 5 8 SW1 switches 5 through 8 set bell test and trigger options as shown 2 3 4 5 6 1 ON 7 8 BELL TEST RINGBACK OPTIONS MUST BE ON FOR LISTED INSTALLATIONS BURG FIRE TRIGGER ON POSITIVE 12V TRIGGER OFF NEGATIVE 0V TRIGGER FIRE TRIGGER ON POSITIVE 12V TRIGGER OFF NEGATIVE 0V TRIGGER CARBON MONOXIDE TRIGGER ON POSITIVE 12V TRIGGER OFF NEGATIVE 0V TRIGGER 745VSD3 005 V0 Figure 4 SW1 Switches 5 8 ...

Страница 4: ...peaker 500mA max steady siren WARRANTY INFORMATION For the latest warranty information please go to http www security honeywell com hsc resources wa index html REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL THAT IS USED WITH THIS DEVICE FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM 2 Corporate Center Drive Suite 100 P O Box 9040 Melville NY 11747 Copyright 2009 ...

Отзывы: