SPECIFICATIONS 

 

Dimensions: 

5-3/8"H x 7-3/8"W x 1-1/4"D  
(137mm x 187mm x 32mm) 

 

Wiring Terminals: 

Data In to Control Panel 

– 

– Ground (12 VDC –) 

+ 12 VDC Power Input 

Data Out from Control Panel

 

 

 

Z4 

+  Wired Zone 4  

 

-   Wired Zone 3 and Zone 4 

Z3 

+  Wired Zone 3 

 

Z2 

+  Wired Zone 2 

 

-  Wired Zone 1 and Zone 2 

Z1 

+  Wired Zone 1 

 

NO 

Relay N.O. contact 

Relay Pole contact (common) 

NC 

Relay N.C. contact  

 - 

 

LEGEND 

= -  (Ground/Common) 

NOTE

: The keypad will display “OPEN CKT” and 

beep periodically when there is a fault that prevents 
data from reaching the keypad. 

 

Display: 

2 x 16 alphanumeric supertwist LCD, backlit. 

Sounder: 

Speaker (fire alarm sound is loud, temporal pattern 
pulsed tone; burglary alarm sound is loud, 
continuous, dual tone). 

Voltage: 

 

12 VDC  

 

Current: 

Alarm rating: 190mA (LCD backlight on, sounder 
on, relay OFF) 

 

Standby rating: 115mA (LCD backlight on, sounder 
off, relay on); 55mA (LCD backlight off, sounder off, 
relay off) 

The control panel determines whether LCD backlighting 
is on or off. When determining the capacity of the control 
panel’s backup battery, use the following chart: 

If Backlighting is . . .  

Then . .

 

On steadily 

Use the 115 mA 

 current 

rating. 

Off when keypad is inactive  Use the 55mA current 
 rating. 

 

 
 
 

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS 
USED FOR WARRANTY INFORMATION AND FOR LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 

 
 
 
 
 
 
 
 
 

165 Eileen Way, Syosset, New York 11791

Copyright © 2006 Honeywell International Inc.

www.honeywell.com/security

 

 

WWW.DIYALARMFORUM.COM 

WWW.DIYALARMFORUM.COM

Содержание Ademco 6164US

Страница 1: ... The four 2K EOLR zones have 300mS response A local programming option allows selecting conventional EOLR type or double balanced type for all zones as a group Each double balanced zone type supports up to 10 sensors Four 2K EOL resistors are furnished as well as four additional 2K resistors for use when double balanced zones are used Do not use the zones on this keypad for commercial fire applica...

Страница 2: ...e of the case back with a tie wrap not supplied WIRE TIE POINT USE AN ADDITIONAL MOUNTING SCREW HERE IF BACK CASE TAMPER IS TO BE USED BREAKOUT FOR SURFACE WIRING BREAKOUT FOR SURFACE WIRING 6164 02 V0 MOUNTING HOLES Figure 2 Wiring Entry Case Back 4 Connect the power data wires to the four screw terminals on the keypad s PC board marked as shown in Figure 3 and as follows Wiring Table Keypad Cont...

Страница 3: ...nsult the control panel s installation guide to select the correct address default 01 Use the key to advance to the Zone Type option In order to use the built in zones and relay the panel must be programmed in the same way as for a 4229 module 5 By pressing the 1 key you can toggle the Zone Type option ZONETYPE ZONETYPE ZONETYPE ZONETYPE EOLR 1 EOLR 1 EOLR 1 EOLR 1 DBALAN DBALAN DBALAN DBALAN Eith...

Страница 4: ...attern pulsed tone burglary alarm sound is loud continuous dual tone Voltage 12 VDC Current Alarm rating 190mA LCD backlight on sounder on relay OFF Standby rating 115mA LCD backlight on sounder off relay on 55mA LCD backlight off sounder off relay off The control panel determines whether LCD backlighting is on or off When determining the capacity of the control panel s backup battery use the foll...

Отзывы: