Step

 

Action

 

Display

 

3. 

To change any of the programming for the wireless key, perform one 
of the following steps in the 

Programming for an Installation WITH 

Local Wireless Keys

 section

.

 

 

For the user code, perform step 5. 

 

For the loop functions, perform steps 6 and 7. 

 

For the on-board relay assignment, perform steps 8 to 10. 

Alternately flashes "d*" with the device number; 
and “--.”

 

4. 

When you have completed editing the wireless keys, press the [

] key 

twice to exit the Program mode

.

 

 

* The keypad will display the last number that was enrolled (i.e., “d3”) 

Note: 

Upon exiting the Program mode, the 6150RF alternately flashes "Ad," the 2-digit keypad address, and the 2-digit receiver 
address.  If either of these is incorrect, repeat steps 1 through 3 in the 

Programming for an Installation Without Local Wireless 

Keys

 section

.

 

TROUBLESHOOTING 

The following error messages cause the 6150RF to produce rapid beeps for 5 seconds. The table below describes the 
error messages and the corrective actions. 

Display

 

Probable Cause

 

Corrective Action 

Lb

 

Low battery in the wireless 
key

 

1.

 

Replace the battery if the wireless key has a replaceable battery. 

2.

 

Replace the transmitter if the wireless key does not have a replaceable 

battery. 

OC

 

Open circuit

 

Verify that the Data Out wire is connected properly. 

1C

 

Incompatible connection

 

Verify that the control panel is not a First Alert-type control panel. 

Check 09 OR 
Check 100 RF 
Receiver OR 
Check 10n RF 
Receiver*

 

1.

 

6150RF Receiver is not 
communicating 

2. 

Another device on the 
keypad terminals is not 
communicating to the 
control panel

 

1.

 

Verify that the Data In wire is connected properly. 

 
2.

 

Verify the wiring connections between the control and all other devices. 

E8

 

Too many RF zones 
programmed

 

Verify the number of transmitters programmed into the control panel 

*n = receiver address programmed in VISTA control panel 

 

SPECIFICATIONS

Physical: 

6-1/4” H x 4-7/8” W x 1” D

  

 

(158.75mm x 123.8mm x 25.4mm) 

Wiring:

 

Refer to Wiring Table on page 2 

Range: 

200' nominal 

Frequency: 

345 MHz 

Voltage: 

12VDC 

Current: 

Standby 80mA 

Backlighting on and 

 Sounder 

on 

105mA 

Relay:  

Normally-Open, 1A, 28VDC 

Sounder: 

Piezo-electric (fire alarm is loud pulsing tone; 
burglary/audible panic alarm is two tone 
sound 

 

 

FOR DETAILS ON THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM, REFER TO THE INSTALLATION INSTRUCTIONS 
FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED. 

 
 

Содержание ADEMCO 6150RF ADEM

Страница 1: ...ith the receiver e g to trip a garage door opener U U U UL L L L This feature is not intended for UL installations Activates relays programmed into the control panel Provides an End User mode to enable disable local wireless keys e g if a user accidentally loses a wireless key Refer to the 6150RF User Guide for this procedure INSTALLING THE 6150RF Locate the 6150RF in an area and at a height where...

Страница 2: ...g guide outlines how to program the wireless keys RF receiver and the House ID in the 6150RF for your installation Two 6150RFs are needed for this application one assigned to partition 1 and one assigned to partition 2 If using an RF keypad on only one partition the 6150RF s partition assignment in panel programming must match the partition If set for Local on a partition control the 6150RF s part...

Страница 3: ... instructions Programming Operations Once you have entered the Program mode you may move to any program address simply by entering the program address number The 6150RF will automatically exit the Program mode if no keys are pressed for 90 seconds While in the Program mode Pressing the key stores the information displayed then moves you to the next prompt and the keypad beeps twice Pressing the ke...

Страница 4: ...ps Step Action Display 1 Enter the Program mode by pressing the 1 and 3 keys simultaneously for a few seconds within 30 seconds after applying power or within 30 seconds after removing the case back Alternately flashes oo and two dashes 2 Enter 1 Keypad Address Enter the 2 digit keypad address 01 31 Press the key to continue Alternately flashes cA and the 2 digit keypad address 3 Enter 2 Receiver ...

Страница 5: ...l number The keypad will beep three times Note If enrolling a wireless key 5804E in high security mode press all four buttons on the wireless key simultaneously Alternately flashes d with the device number and the serial number 4 Press the key to accept the serial number OR press the key to reject the serial number If you accept the serial number the 6150RF beeps two times If you reject the serial...

Страница 6: ...ays o and alternately flashes the loop number and the relay action 10 Repeat step 9 for the rest of the loops 11 When all loops have been programmed for the wireless key press the key Flashes d followed by the device number 12 The 6150RF automatically displays the next available device number one that does not have a serial number If you want to program additional wireless keys repeat steps 3 thro...

Страница 7: ...ry if the wireless key has a replaceable battery 2 Replace the transmitter if the wireless key does not have a replaceable battery OC Open circuit Verify that the Data Out wire is connected properly 1C Incompatible connection Verify that the control panel is not a First Alert type control panel Check 09 OR Check 100 RF Receiver OR Check 10n RF Receiver 1 6150RF Receiver is not communicating 2 Anot...

Страница 8: ...ity outdoor antenna installed Reorient the receiving antenna until interference is reduced or eliminated Move the radio or television receiver away from the receiver control Move the antenna leads away from any wire runs to the receiver control Plug the receiver control into a different outlet so that it and the radio or television receiver are on different branch circuits Consult the dealer or an...

Отзывы: