B.
Indoor
Unit
Mounting
(1) The indoor unit should be mounted in the avionics bay of the UAV.
(2) The indoor unit may be mounted in any orientation
– The label is on the back, exterior face of the Indoor Unit.
(3) The indoor unit’s environment should be maintained within its environmental parameters.
– Anti-vibration mounts (not supplied) can be used to reduce the severity of the vibration.
(4) The indoor unit should be bolted to the floo
r o
f the avionics bay or on the external fuselage with
4 M4 bolts and torqued to 2.0 to 2.4 N.m.
NOTE:
Mounting Hardware not included. Hardware to be supplied by customer based
on installation.
(5) The SIM card should be fully inserted into the SIM card slot on the front face of the indoor unit.
(6) To ensure that the indoor unit can dissipate heat, refer to Paragraph 7.B.
(7) Refer to Figure 6 for Indoor Unit dimensions.
Page 1
6
1
8
Feb 2021
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
SMALL SATCOM