Administrating the Device
38
White Balance:
Auto: will adjust the white balance automatically.
Hold: will hold the white balance.
Iris/Exposure Control:
Auto Iris: will adjust the DC Iris automatically.
This Camera is built-in a DC-Iris lens. In case, the “Auto Iris” mode is selected, the Camera
will control DC Iris automatically.
Sometimes, the Auto Iris may work abnormally under some environments. In this case, user
can click “Calibrate” button to adjust Auto Iris function again.
Auto Exposure: will adjust the image sensor exposure automatically.
Hold Exposure: will hold the exposure setting.
Manual Exposure: User can configure sensor exposure to fixed setting.
Outdoor: In case this camera is installed in outdoor, then shall enable this option.
Otherwise, disable it. The feature can improve auto-exposure performance under strong
sunlight.
Maximum Exposure Time:
Set the Maximum Exposure Time. However, the real exposure time may be shorter if good
light condition.
Power Frequency:
Frequency of power line: 50 or 60Hz.