background image

4. FDAP Installation 

4.3. FDAP installation tasks 

36 

OneWireless Field Device Access Point User's Guide  

R200 

 

Honeywell Confidential & Proprietary 

October 2010 

all cabling must be routed through the conduit and must be enclosed within the junction 
box. 

After all the FDAPs are installed and connected at their site locations, turn on the FDAPs 
to verify the wireless network communications. 

 

Содержание 51306533

Страница 1: ...t Honeywell Confidential Proprietary This work contains valuable confidential and proprietary information Disclosure use or reproduction outside of Honeywell International Inc is prohibited except as authorized in writing This unpublished work is protected by the laws of the United States and other countries ...

Страница 2: ...cular purpose and makes no express warranties except as may be stated in its written agreement with and for its customers In no event is Honeywell liable to anyone for any indirect special or consequential damages The information and specifications in this document are subject to change without notice Honeywell PlantScape Experion PKS and TotalPlant are registered trademarks of Honeywell Internati...

Страница 3: ... Honeywell s OneWireless network solution for industrial control Release Information Document Name Document ID Release Number Publication Date Field Device Access Point User s Guide fdapug 200 October 2010 Document Category References The following list identifies all documents that may be source of reference for material discussed in this publication Document Title OneWireless R200 Hardware Plann...

Страница 4: ...17 1860 W Garden Lane Phoenix AZ 85027 USA Europe Middle East and Africa EMEA Contact Phone Fascimile Mail Honeywell TAC EMEA 32 2 728 2345 32 2 728 2696 TAC BE02 Hermes Plaza Hermeslaan 1H B 1831 Diegem Belgium Pacific Contact Phone Fascimile Mail Email Honeywell Global TAC Pacific 1300 364 822 toll free within Australia 61 8 9362 9559 outside Australia 61 8 9362 9564 Honeywell Limited Australia ...

Страница 5: ...hina 86 21 2219 6888 800 820 0237 400 820 0386 Honeywell China Co Ltd 33 F Tower A City Center 100 Zunyi Rd Shanghai 200051 People s Republic of China Global TAC China honeywell com Singapore Contact Phone Fascimile Mail Email Honeywell Global TAC South East Asia 65 6580 3500 65 6580 3501 65 6445 3033 Honeywell Private Limited Honeywell Building 17 Changi Business Park Central 1 Singapore 486073 G...

Страница 6: ...al TAC Japan 81 3 6730 7160 81 3 6730 7228 Honeywell Japan Inc New Pier Takeshiba South Tower Building 20th Floor 1 16 1 Kaigan Minato ku Tokyo 105 0022 Japan Global TAC JapanJA25 honeywell com Elsewhere Call your nearest Honeywell office World Wide Web Honeywell Solution Support Online http www honeywell com ps Training Classes Honeywell Automation College http www automationcollege com ...

Страница 7: ...TION Indicates a situation which if not avoided may result in equipment or work data on the system being damaged or lost or may result in the inability to properly operate the process CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices CAUTION symbol on the equipment refers the user to...

Страница 8: ...f the protective earth green or green yellow supply system conductor Functional earth terminal Used for non safety purposes such as noise immunity improvement NOTE This connection shall be bonded to Protective Earth at the source of supply in accordance with national local electrical code requirements Earth Ground Functional earth connection NOTE This connection shall be bonded to Protective Earth...

Страница 9: ...tatements 17 RF safety statement 18 Agency approval marks 19 2 2 Declarations of conformity and regulatory information 21 FDAP device DoC statement 21 Intended country usage 22 3 ABOUT FDAP 23 3 1 FDAP description 23 3 2 Types of FDAPs 23 Standalone FDAP 23 Embedded FDAP 24 FDAP as field router 24 3 3 FDAP Models 24 3 4 Physical description of FDAP 25 FDAP enclosure 25 IR ports 26 Antennas 26 LED ...

Страница 10: ... 33 Outdoor protection kit 33 Installing lighting arrestor 33 Mounting the FDAP 33 Powering up the FDAP 35 5 FDAP CONFIGURATION 37 5 1 Overview 37 5 2 Provisioning a FDAP 37 5 3 Viewing FDAP details 37 5 4 Upgrading firmware of FDAP 39 6 FDAP MONITORING 41 6 1 Overview 41 6 2 Verify connectivity using maps 41 6 3 Monitoring using alarms 41 6 4 Monitoring using reports 41 Device Health Report 42 6 ...

Страница 11: ...Contents R200 OneWireless Field Device Access Point User s Guide xi October 2010 Honeywell Confidential Proprietary 8 1 Overview 45 FDAP failure indications 45 Restarting FDAP 45 ...

Страница 12: ...Contents Tables xii OneWireless Field Device Access Point User s Guide R200 Honeywell Confidential Proprietary October 2010 Tables Table 1 FDAP specifications 28 Table 2 FDAP installation tasks 32 ...

Страница 13: ...evice Access Point User s Guide xiii October 2010 Honeywell Confidential Proprietary Figures Figure 1 OneWireless network 16 Figure 2 Physical description of FDAP 25 Figure 3 Pole mounting 34 Figure 4 Wall mounting 35 Figure 5 FDAP details 38 ...

Страница 14: ...Contents Figures xiv OneWireless Field Device Access Point User s Guide R200 Honeywell Confidential Proprietary October 2010 ...

Страница 15: ...less network seamlessly extends the process control network to a plant that has the capability to Install battery powered wireless field instruments to collect additional data to improve control strategies or conform to regulations at lower costs Empowers a mobile workforce by providing remote access to process data and other plant related information Enhances plant security by cost effectively im...

Страница 16: ...r the process industry with wireless access points It is capable of communicating with ISA100 field instruments as well as Wi Fi clients The following diagram displays a typical OneWireless network Figure 1 OneWireless network For more information about OneWireless network topologies refer to the section Planning the OneWireless Network in OneWireless Hardware Planning and Installation Guide ...

Страница 17: ...rference in a residential installation This equipment generates uses and can radiates radiofrequency energy and if not installed and used in accordance with these instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user should correct the interference at their own expense Int...

Страница 18: ... configurations must be satisfied Remote point to multi point antenna s for this unit must be fixed and mounted on outdoor permanent structures with a separation distance between the antenna s of greater than 20cm and a separation distance of at least 20cm from all persons Remote fixed point to point antenna s for this unit must be fixed and mounted on outdoor permanent structures with a separatio...

Страница 19: ...ted and certified to be reliable Class I Division 1 Groups C D Class I Division 2 Groups A B C D Class I Zone 2 Ex nA IIC The Canadian Standards mark means the equipment has been tested and meets applicable standards for safety and or performance Class I Division 1 Groups C D Class I Division 2 Groups A B C D Class I Zone 2 Ex nA IIC The conformité européenne CE mark means that radio equipment use...

Страница 20: ...C mark means the equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules FCC Part 15 Subpart B FCC Part 15 Subpart C FCC Part 15 Subpart E The C Check mark means that it is a certification trade mark registered to ACMA Australian Communications and Media Authority in Australia under the Trade Marks Act 1995 and to RSM in New Z...

Страница 21: ...rietary 2 2 Declarations of conformity and regulatory information This section contains the Declaration of Conformity DoC statement for the FDAP device and the countries it is intended to be used in For a complete list of compliant models contact Honeywell FDAP device DoC statement Following is Honeywell s Declaration of Conformity DOC for the OneWireless FDAP device Information Required ...

Страница 22: ...ountry ISO 3166 2 letter code Country ISO 3166 2 letter code North America United States US Canada CA Australia and New Zealand Australia AU New Zealand NZ European Union Austria AT Latvia LV Belgium BE Liechtenstein LI Bulgaria BG Lithuania LT Cyprus CY Malta MT Czech Republic CZ Netherlands NL Denmark DK Norway NO Estonia EE Poland PL Finland FI Portugal PT France FR Romania RO Germany DE Slovak...

Страница 23: ... at 24V DC and 110 120V AC power 10 100 Gigabit Ethernet and has dual antennas for diversity FDAP is an industrial meshing access points providing secure and reliable wireless coverage for ISA100 11a field instruments only Once deployed in the field FDAPs self discover and self organize into a managed secure and redundant wireless field instrument mesh network It acts as a bridge between the senso...

Страница 24: ...sioning which is accessible outside the enclosure If you need backward compatibility with FHSS field instrumentation use Multinode with embedded FDAP FDAP as field router FDAP can be used as a field router FR If FDAP is not connected to the physical ethernet it functions as a line powered FR FDAP as line powered FR option can be useful for extending field mesh into hazardous environments where nor...

Страница 25: ...s inherently watertight to MIL STD 202 method 106 The rigid conduit hub has a gasket to seal out water and dust A rigid conduit hub internal and external ground studs and removable cover are provided for field installation Externally accessible IR port and status LEDs allows you to commission the FDAP and get status information respectively The IR port and LED holes are covered with an outdoor rat...

Страница 26: ...and cost per wireless I O FDAP has integral and remote surge arrestors as well as integral and remote antennas The antenna selection includes integrated omni directional antennas and remote mounted omni directional antennas In addition the FDAP supports a variety of high and low gain directional antennas to provide flexibility in installation and maximum performance of the wireless system LED indi...

Страница 27: ...creases ISA100 coverage range by 1 5 times over Multinodes or routing wireless field instruments It enables a 450 meters connection with wireless field instruments with standard integral antennas 10 100 Gigabit Fast Ethernet FDAP has 10 100 Gigabit Fast Ethernet and connects wireless sensor network to wired network and connects ISA100 network to the wired network It forms a self forming self heali...

Страница 28: ...a External Ports and connections 2 X external antenna ports for 2 4 GHz ISA100 11a field instruments Internal Connections 1 X 10 100 Mbps auto negotiation Ethernet port 1 X shielded power cable 1 X grounding cable Mechanical Shock 4G Data Rates and Modulations Radio 250 Kbps DSSS OQPSK Wire 10 100 Mbps Fast Ethernet Frequency band and operating channels Unlicensed ISM Band 2 4 2 483 GHz 15 DSSS ch...

Страница 29: ... 11a Field Instruments at 1 second reporting rate 80 ISA100 11a Field Instruments at 5 seconds or more reporting rate Environmental Operating Temperature 40ºC to 75ºC 4 F to 140 F Others Transportation and Storage Temperature 40ºC to 85 ºC Operating Humidity 0 100 non condensing Transportation and Storage Humidity 0 100 non condensing For more information about FDAP specifications refer to Honeywe...

Страница 30: ... when FDAPs are added to or removed from the network Infrared security In addition to data encryption ISA100 standard requires each FDAP to be authenticated before joining the network OneWireless network supports over the air and infrared authentication key distribution OneWireless network relies on a more secured infrared authentication key distribution method as it requires users to be physicall...

Страница 31: ...ysis must be conducted on the 2 40 2 49GHz band and 5 7 5 9 GHz band if available to be used to detect any potential RF interference Strong interference sources must be addressed removed avoided or minimized before the installation Note that some frequencies may not be available for use in some locations and countries A point to point 2 node mesh must be staged in various locations to measure the ...

Страница 32: ... 5 Assemble and mount the FDAP 6 Install the FDAP based on the Ethernet connection If ethernet cable is connected it acts as a FDAP and if the ethernet cable is removed it acts as line powered FR 7 Construct conduit and cable runs for power and Ethernet Connect power and Ethernet cabling 8 Provide grounding to FDAP 9 Power on FDAP in the network The installation of FDAP is complete at the installa...

Страница 33: ...the installation This kit contains lightning arrestors and ground cables designed for installation with FDAP ATTENTION If the system is mounted outdoors where CE Mark certification is required use of the Outdoor Protection Kit or equivalent is mandatory An outdoor protection kit must be used for preventing the lightning damage when the FDAP is mounted outdoors The outdoor protection kit contains t...

Страница 34: ...es the following items Mounting plate U bolts with nuts Screws to attach the FDAP to the mounting plate The pole mounting kit comprises a mounting plate U bolts and nuts as shown in Figure 3 When using the mounting plate for pole installation secure the FDAP to the bracket using the screws supplied with the bracket kit The FDAP can be mounted to the left or to the right of the pole using the same ...

Страница 35: ...re 4 Wall mounting Powering up the FDAP You must ensure that the FDAPs are earthed grounded properly by a certified and authorized personnel and that it conforms to all applicable codes and regulations The materials required to provide a proper earth or ground are defined by local regulations and must be obtained locally to ensure that the correct safety environment is achieved Power cabling from ...

Страница 36: ...ser s Guide R200 Honeywell Confidential Proprietary October 2010 all cabling must be routed through the conduit and must be enclosed within the junction box After all the FDAPs are installed and connected at their site locations turn on the FDAPs to verify the wireless network communications ...

Страница 37: ...devices You can configure the FDAP by using OneWireless application WDM UI For more information about the WDM UI refer to OneWireless Wireless Device Manager User s Guide 5 2 Provisioning a FDAP You can send provisioning information security wireless from Provisioning Handheld to the FDAP using IR communication link or using over the air provisioning ISA100 Before you provision a FDAP ensure that ...

Страница 38: ...ndor Model Serial and Radio Revision You can rename the Tag Name Address You can view address details like Address Short Address and IP6 Address Status You can view status details like Power supply status Restart Count Uptime Drop Offs and Reset Counts Device Role You can view the device role details like provisioning device security manager access point and so on Data Layer Management You can vie...

Страница 39: ...t User s Guide 39 October 2010 Honeywell Confidential Proprietary 5 4 Upgrading firmware of FDAP After configuring and provisioning FDAP you can upgrade the FDAP firmware For information about the procedure to upgrade a firmware for FDAP refer to OneWireless Wireless Device Manager User s Guide ...

Страница 40: ...5 FDAP Configuration 5 4 Upgrading firmware of FDAP 40 OneWireless Field Device Access Point User s Guide R200 Honeywell Confidential Proprietary October 2010 ...

Страница 41: ...ctivity You can navigate to the device in the topology map and check the link signal quality and connectivity In addition you can examine device communication statistics information like Receive Signal Quality Index RSQI and Receive Signal Strength Index RSSI 6 3 Monitoring using alarms You can monitor active alarms generated by FDAPs The Active Alarms tab lists the device type priority location s...

Страница 42: ...o tag suspected devices for maintenance inspection The report includes battery health devices that lost communication with the system For information about reports refer to OneWireless Wireless Device Manager User s Guide 6 5 System logs The system log contains events logged in the system You can view and export log details For information about system logs refer to OneWireless Wireless Device Man...

Страница 43: ... be replaced and determine the cause of failure by reviewing the logs and alarms Failed device alarm is generated and points to the FDAP that failed and you can identify the FDAP to be replaced from the list of troubled devices Once the replacement is done the system automatically generates device replaced log entry event For information about the procedure to replace a FDAP refer to OneWireless W...

Страница 44: ...7 FDAP Maintenance 7 3 Deleting a FDAP 44 OneWireless Field Device Access Point User s Guide R200 Honeywell Confidential Proprietary October 2010 ...

Страница 45: ...nclosure any failure within a FDAP requires a replacement of the FDAP If a fault or a failure is indicated or suspected in a FDAP in the network there are many ways to diagnose a problem You can Monitor using alarms Monitoring using reports System logs FDAP failure indications Failure indication may be signaled through the FDAP status LEDs Restarting FDAP You can restart the FDAP if a failure is s...

Страница 46: ...8 Troubleshooting 8 1 Overview 46 OneWireless Field Device Access Point User s Guide R200 Honeywell Confidential Proprietary October 2010 ...

Страница 47: ......

Страница 48: ...Honeywell Process Solutions 1860 W Rose Garden Lane Phoenix AZ 85027 USA ...