Using the Transmitter
How to Program the Transmitter
Function 5 - Reset Network Parameters to Zero
This function,
which should only be used by authorized, fully
qualified technicians
, resets the transmitter’s network parameters to
zero, enabling the transmitter to look for a new controller in Association
mode (see 301C manual for details).
•
Press pushbutton 1
•
Press pushbutton 2, count 6 blinks and release.
•
Press pushbutton 1.
Function 6 - Activate a Check Test
This test essentially sends a neutral command that causes the
transmitter to react, thus enabling you to tell whether it is still
functioning.
•
Press pushbutton 1
•
Press pushbutton 2, count 7 blinks and release.
•
Press pushbutton 1.
Once this function has been executed, the LEDs will display the result:
Success: Both LEDs blink simultaneously 6 times, for three cycles.
Failure:
LED 1 blinks 6 times, for 3 cycles while LED 2 blinks non-
stop throughout the cycles.
This function resets the transmitter; once reset, transmitters
may change IDs, and thus render controller Events and
Groups inoperable.
Содержание 301W
Страница 2: ......
Страница 3: ...Wireless Gas Monitoring Device 301W Installation and User Manual ERP 511398 5 07 ...
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 22: ......
Страница 34: ......
Страница 38: ......
Страница 44: ......
Страница 45: ...Dispositif de détection de gaz sans fils 301W Manuel de l utilisateur ERP 511398 5 07 ...
Страница 46: ......
Страница 48: ......
Страница 50: ......
Страница 52: ......
Страница 64: ......
Страница 72: ......
Страница 86: ......