background image

 

ADEMCO 5815 

Door/Window Transmitter 

 

Installation and Setup Guide 

 

 

Figure 1.  Mounting Plate and Case 

GENERAL INFORMATION 

The 

Honeywell 

Ademco 

5815  is  a  two-zone 

Door/Window Transmitter that has its own unique serial 
number. The control unit is required to "enroll" the serial 
number prior to its usage in the alarm system. Refer to 
the  control  unit's  installation  instructions  for  further 
details. 

Note:

  During  programming  of  the  control  unit, 

5815  transmitters  should  be  treated  as  "RF"  (i.e., 
supervised RF) Type (

mandatory for UL installations

). 

The 5815 provides two input loops (zones): the 

first

 for a 

wired closed-circuit contact loop, and the 

second

 for its 

built-in  reed  switch  (used in conjunction with a magnet, 
as  described  below).  One  or  both  inputs  may  be  used. 

For  UL  installations,  a  contact  may  not  be  more than 3 
feet from the transmitter.

 

The  5815  includes  a  built-in  cover  tamper,  which  is 
activated when the cover is removed. 

MOUNTING 

For  proper  orientation  of  the  unit  in  relation  to  the  
mounting  plate,  loop  wiring,  and/or  magnet,  read  all  of 
this section before installing the unit. 

The description that follows assumes that the unit will be 
mounted as shown in the diagrams, with the magnet (if 
used) located in one of the positions shown in Figure 2. 
The unit may, however, be installed in 

any

 direction, as 

long as the relationship of the unit to its mounting plate 
and (if used) magnet is maintained.

 

Although  the  unit can be mounted directly to a surface, 
we  recommend  that  the  mounting  plate  be  used,  for 
ease in removing the unit for servicing should it become 
necessary. 

Before  mounting  the  transmitter  permanently,  conduct 
Go/No  Go  tests  (see  control's  instructions)  to  verify 
adequate  signal  strength  and  reorient  or  relocate  the 
transmitter if necessary.

 

1.  Remove  the  transmitter's  top  cover 

by  inserting 

the  flat  blade  of  a  small  screwdriver  into  the  pry-off 
slot  at  one  end  of  the  unit  (see  Fig.  1  for  location), 
and  slightly  twisting  the  blade  until  the  cover 
disengages.   

IMPORTANT:

 DO NOT REMOVE the circuit board from 

the back case plastic.

 

     Figure 2. 5815 (shown without cover)

 

2.  Disengage  the  attached  mounting  plate  from  the 

case

  by  inserting  the  blade  of  a  small  screwdriver 

into  the  locking  tab  release  window  (see  Figure  1) 
and pressing it against the locking tab (also shown in 
Figure  1),  while  sliding  the  mounting  plate  upward 
along the case back until free. 

3.  Install  the  mounting  plate,

  with  its  two  case- 

holding  posts  pointing  up  (in  this  example),  in  the 
location  selected  as  described  in  the  control  panel's 
installation  instructions.  Use  the  flat-head  screws 
supplied. 

 

Note: 

If  a  wired  contact  loop  is  to  be  used,

 

with 

concealed

  wiring,  the  wire  exit  hole  in  the  wall  must 

be  located  under  the  wire  entry  hole  in  the  case  as 
shown  in  Figure  2,  and  no  more  than  1/4"  in 
diameter. 

4.  If  a  wired  contact  loop  is  to  be  used,

  feed 

concealed

  wiring  through  the  slot  in  the  case  back, 

but  do  not  connect  to  the  terminal  block  yet.  For 

surface

  wiring  entry,  two  thin  "breakout"  areas  are 

provided in the case wall (see Figure 1).  

5.  Attach  the  case  back  to  the  mounting  plate 

by 

sliding the keyhole slots in the case back down onto 
the mounting plate's case holding posts. The locking 
tab will click as the case back locks in place. 

6.  If  a  reed  switch  is  to  be  used,

  mount  a  No. 5899 

Magnet  (obtained  separately)  adjacent  to  the  reed 
switch, or adjacent to the top of the case (see Figure 
2).  In  either  case,  the  magnet  must  be  mounted 
within one-half inch of the reed switch. 

LOOP WIRING CONNECTIONS

 (If used)

 

With  the  battery  still  not  inserted,  connect  the  contact 
loop wires to the unit's loop terminals (see Figure 2). 

 

Caution:

 

Make  sure  that  the  bared  sections  of  the 

loop  wires  do  not  short  to  the  reed  switch  or 
antenna.

 

The  contact  loop  must  use  closed-circuit  devices.

  The 

loop response time is a nominal 100mSec. 

NOTE:

  If  the  contact  loop  is  not  to  be  used,  no 

connection  is  needed  across  the  loop  terminals. 