![Honda Eu7000is Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/honda/eu7000is/eu7000is_manual_2156276018.webp)
EU-101
Date Revised: March 2021 (PSV52522-S)
© 1998-2021 American Honda Motor Co., Inc.—All Rights Reserved
EU Mo
dels
*: No error code displayed. Can be displayed in Error log mode
Error code
Overload
indicator
Check/
Oil Alert
indicator
Error name
Detection
condition
Error
recognition
number of
times
Fail-safe
Inverter unit and
GCU
communication
error
Communication
error between the
inverter and GCU is
detected.
2
Engine is stopped
Inverter unit internal
communication
error
Communication
error between the
master inverter and
slave inverter is
detected.
1
Engine is stopped
*
Inverter unit
excessive current
protection activated
Excessive current
caused by overload
is detected.
1
After shutting down the AC
output, the engine is left
running at
2,400 rpm.
*
Inverter unit
excessive voltage
protection activated
Excessive voltage
caused by internal
failure is detected.
1
After shutting down the AC
output, the engine is left
running at
2,400 rpm.
*
Inverter unit
overheated
protection activated
FET device/power
module
temperature in the
inverter exceeds
the specified value.
1
After shutting down the AC
output, the engine is left
running at
2,400 rpm.
Inverter unit internal
failure
(A/D input error)
There is
abnormality in the
figure monitored by
the inverter.
2
Engine is stopped
Inverter unit internal
failure
(FET open)
There is
abnormality in the
FET device in the
inverter.
2
Engine is stopped
Inverter unit internal
failure
(FET short)
There is
abnormality in the
FET device in the
inverter.
1
Engine is stopped
Inverter unit internal
failure
(Diode line short)
There is
abnormality in the
diode in the
inverter.
1
Engine is stopped
Inverter unit internal
failure
(SCR short)
There is
abnormality in the
SCR in the inverter.
1
Engine is stopped
RAM/ROM failure
Inverter internal
memory registry
error is detected.
1
Engine is stopped
*
Inverter unit short
protection activated
Excessive current
caused by a short
circuit is detected.
1
After shutting down the AC
output, the engine is left
running at
2,400 rpm.
AAT sensor (GCU
internal) failure
AAT sensor in the
GCU abnormality is
detected.
1
Display only