28
OPERATION
1. Unplug all tools and appliances from the generator.
2. Start the engine (see page 23).
When the GFCI is operating normally, the indicator will continuously
light green.
Light order:
(red) Blink once
(green) Light once
(red) Blink once
(green) Lights continuously
• If the green indicator light does not come on, press the RESET
button.
• If the red indicator starts to blink continuously, contact an authorized
Honda generator dealer.
3. Press the TEST button:
• The RESET button will pop out and the green indicator will go off.
• If the GFCI does not function as described, contact an authorized
Honda generator dealer.