23
OPERATION
STARTING THE ENGINE
To prevent a possible fire, keep the generator at least 3 feet (1 meter)
away from building walls and other equipment during operation. Do not
place flammable objects close to the engine.
• Operating this generator less than 3 feet (1 meter) from a building or
other obstruction can cause overheating and damage the generator.
• For proper cooling, allow at least 3 feet (1 meter) of empty space
above and around the generator.
Keep all cooling holes open and clear of debris, mud, water, etc.
Cooling holes are located on the side panel, the control panel, and
the bottom of the generator. If the cooling holes are blocked, the
generator may overheat and damage the engine, inverter, or
windings.
Refer to
SAFE OPERATING PRECAUTIONS
on page 22 and perform
the
IS YOUR GEN ERATOR READY TO GO?
checks (see page 20).
Refer to the
AC OPERATION
(see page 30) for connecting loads to the
generator.
1. Make sure that all appliances are disconnected from the AC receptacle.
2. Turn the fuel filler cap vent lever to the ON position.
FUEL FILLER CAP VENT LEVER
ON