Case of Problem
1.
Alarm is ON when the following conditions occur.
①
Fuse is blown caused by overcurrent.
②
Soundome moving upward
③
Soundome moving downward
Therefore, alarm turns OFF after soundome stops.
2.
Stop the vessel when confirming the condition of problem. Turn OFF the electric hoist
before starting the operation.
①
Remove the clamping knob and open the cover.
②
Remove the fuse cover to see if the fuse is blown. (2A/125V 2pcs)
Exchange old fuse to new one if broken.
Caution: Use fuse less than 2A spec.
③
After fuse exchange, turn ON the power and confirm the operation.
If the motor still does not activate, turn OFF the power of unit.
Raise the soundome manually with the following procedure.
Use 17mm wrench for hexagon nut on the top and rotate it clockwise.
(Soundome will move upward.)
Do NOT rotate the nut to counter-clockwise since the nut gets loosen.
Caution: Do NOT raise the soundome too high. That causes the damage onto the
upper limit switch. Raise the soundome by looking at the positioning of limit switch
and operation lever.
3.
After foreign material is stuck inside the pipe, return to the port for safe tie-up, and remove
the material.
22
Upper
Limit Switch
Operation lever
Содержание HONDEX HE-773-Di
Страница 1: ......
Страница 13: ...Insert O ring Insert the rubber bush into transducer part Insert the cable of soundome 12...