background image

Wiring Diagram

HR-REP-120
(Side View)

1.

Find a suitable location for the Hybrid Repeater.
Place the repeater in a convenient and accessible
location. 

Note:

Hybrid Repeaters must be within 60

feet (18 m) of an RF Processor or another repeater
when using the RF Link for repeater-to-repeater or
repeater-to-processor communication.

2.

Connect Hybrid Repeater Link (if applicable).

Connect the Hybrid Repeater Link communication
wires from the HomeWorks

®

Processor (or previous

Hybrid Repeater in the daisy chain) to the terminal
block on the Hybrid Repeater (see Wiring
Diagram). Each terminal will accept up to three 
22-18 AWG (0.5-1.0 mm

2

) wires. 

Note: 

If using the plug-in adapter to power the

repeater, 

DO NOT 

connect the +15 V terminal 

(terminal 2).

3.

Apply power to the Hybrid Repeater. 

If the

Hybrid Repeater is to be powered by the Hybrid
Repeater Link, apply power by turning on the

HomeWorks 

Processor. If the Hybrid Repeater is to

be powered by the plug-in adapter, insert the
adapter cord plug into the jack on the Hybrid
Repeater, then plug the adpater into a standard
wall receptacle.

2

English

Français

Esp

añol

Português

Installation

Wall Mounting

Hybrid Repeaters may be wall mounted using the 
supplied wall bracket.

STATUS and
TEST LEDs will
be dimly lit when
first powered

Plug in
power cord
and adapter

Plug in
adapter jack

1. 

Attach wall bracket to wall using the supplied
screws and wall anchors.

2. 

Place power cord into notches at top and bottom of
wall bracket. Wrap excess power cord around the
cord holder. Route Hybrid Repeater Link wiring
through hole in wall bracket and out through side
cutout. Align repeater and snap onto wall bracket.

UP

UP

MUX
MUX
+15 V
COM

Power Cord

Hybrid
Repeater Link
Wiring

RF TX/RX LEDs

Indicate RF Link
activity.

STATUS LED

Indicates the status of the 

HomeWorks

system.
Note: When the Hybrid Repeater is
powered, but has not yet been assigned
an address from the HomeWorks
Illumination Software, the STATUS and
TEST LEDs will be dimly illuminated.

Operation

TEST LED

A slow flash indicates
RF communications
tests are in progress

STATUS Button

Used when addressing the
Hybrid Repeater from the

HomeWorks

Illumination

TM

Software.

TEST Button

Activates RF communication
tests. To activate the tests,
press and hold the TEST
Button until the TEST LED
begins to flash.

Note:

For communication tests,

the Hybrid Repeater,

HomeWorks

Processor, and

other RF devices must first be
configured and addressed
using the HomeWorks

Illumination

Software.

WIRED TX/RX LEDs

Indicate Wired Link
activity.