English
Français
Esp
añol
Português
1
Important Notes
Codes:
Install in accordance with all local and nation-
al electrical codes.
Power:
The Hybrid Repeater can be powered from
EITHER of two sources:
1. Adapter power.
Use only the adapter pro-
vided with the Hybrid Repeater (Lutron
model # T120-9DC-3-WH).
Caution -
Using an adapter not rated at the
following specifications could damage the
repeater and possibly overheat the adapter.
• Input: 120 V 60 Hz
• Output: 9 V
300 mA
NEC Class 2; IEC PELV
2. Link power.
Use only power supplied via a
HomeWorks
Processor Hybrid Repeater
Link or a
HomeWorks
auxiliary power sup-
ply. (See section about the HWI-PS in the
HomeWorks
Technical Reference Guide or
Application Note HW-104.) Each hybrid
repeater counts as 30 LEDs.
Note:
An RF Processor does not supply
power on the Hybrid Repeater Link.
Environment:
Ambient operating temperature:
32-104°F (0-40°C), 0-90% humidity, non-condensing.
Indoor use only.
Please Read Before Installing
Installation Instructions
Overview
HomeWorks
Hybrid Repeaters add RF capability to
HomeWorks
processors configured with a Hybrid
Repeater Link and provide an additional coverage
area for radio frequency (RF) signals sent between
HomeWorks
RF Dimmers/Switches, RF Keypads, and
RF Processors. Each repeater covers a sphere of
approximately 2500 square feet (232m
2
) of living
space. Up to five (5) repeating devices may be placed
in a
HomeWorks
RF system (a
HomeWorks
RF
Processor counts as one of the repeating devices).
Hybrid Repeater
HR-REP-120
120 V 60
Hz (9 V 300 mA adapter)
HR-REP-120
Hybrid Repeater Wiring:
Hybrid Repeater wiring
must be in a daisy chain configuration. The total
length of wire on the Hybrid Repeater Link may be up
to 1000 feet (305 m), and may contain up to five (5)
Hybrid Repeaters.
Cleaning:
To clean, wipe with a clean damp cloth.
DO
NOT
use any chemical cleaning solutions.
Device Placement:
HomeWorks
Hybrid Repeaters
must be located within 30 feet (9 m) of the RF
Dimmers, Switches, and Keypads they are covering.
Hybrid Repeaters must also be within 60 feet (18 m)
of an RF Processor or another repeater when using
the RF Link for repeater-to-repeater or repeater-to-
processor communication. When using the Wired Link
for repeater-to-repeater or repeater-to-processor com-
munication, a total wire length of 1000 feet (305 m)
may be used.
FCC Information
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, persuant to part 15 of the FCC rules.
Operation is subject to the following:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.