background image

 4
 

Homewerks.com

Pre-Installation

PLANNING INSTALLATION

Before beginning assembly of the product, make sure all parts are present. Compare parts with the package contents list and hardware 
contents. If any part is missing or damaged, do not attempt to assemble, install, or operate the product. Contact customer service for 
replacement parts.

NOTE: 

Keep your receipt and these instructions for proof of purchase.

 

Check area above installation location to be sure that wiring can run to the planned location and that duct work can be run and  
the area is sufficient for proper ventilation.

 

Inspect duct work and wiring before proceeding with installation.

 

Before installation, provide inspection and future maintenance access at a location that will not interfere with installation work.

 

You may need the help of a second person to install this fan; one person on the attic side and one on the room side.

NOTE: 

Installation may vary depending on how the previous bath fan was installed. Supplies necessary for the installation of your bath  

fan are not all included. However, most are available at your local home improvement or hardware store.

Wiring Diagram

WARNING:

 Wiring must comply with all 

applicable electrical codes. Turn off power  
before removing or installing connectors.

WARNING:

 COPPER TO COPPER ONLY. Do not use 

aluminum wire.

CAUTION:

 Accessory part (quick connector) 

should meet installation instructions below.

NOTE:

 The connector is reusable on solid wires of 

the same wire gauge or smaller. Do not reuse the 
connector on stranded wires.

 

Strip wires 3/8 in. - 1/2 in.

 

Grip the wire firmly and push the stripped end of  
the wire into the open port of the connector. Use  
only one conductor per port.

 

Verify the stripped end of the wires is fully inserted 
to the back of the connector.

CAUTION:

 Wiring maximum temperature rating 221˚F (105˚C). 600V maximum for building wiring and 1,000V maximum for signs and light 

fixtures. The acceptable wire range is 18-16 AWG Sol. Cu.

Capacitor 

For Long 

Life of 

Motor

Automatic Terminal Switch

Motor

Fan Housing

Electrical 

Box

Humidity

Sensor

To 120V / 60 Hz

Black Wire

White Wire

To Switch

To Neutral

Green Wire To Ground

Quick Connector

Product Wires

House 

Wires

Содержание 7136-02HW

Страница 1: ...E GUIDE BATHROOM VENTILATION FAN WITH HUMIDITY SENSOR Need Help Please call our toll free line at 877 319 3757 7 30 am to 4 30 pm CST for additional assistance or service HOMEWERKS COM Model 7136 02HW...

Страница 2: ...not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages WARNING To reduce the risk of fire electric shock or injury to persons observe the following Use this u...

Страница 3: ...sult of neglect misuse accident improper installation or use other than the purpose SHALL VOID THIS WARRANTY Shipping costs for return product as part of a claim on the warranty must be paid for by th...

Страница 4: ...ry for the installation of your bath fan are not all included However most are available at your local home improvement or hardware store Wiring Diagram WARNING Wiring must comply with all applicable...

Страница 5: ...Knife Electric Drill PACKAGE CONTENTS Part Description Quantity A Fan Housing 1 B Grille 1 HARDWARE INCLUDED NOTE Hardware not shown at actual size Part Description Quantity AA Wood Screw M4 x 30 mm 8...

Страница 6: ...lush mount to the joist The flange should be flush with the ceiling board If spacing between joists is 12 in apart use 4 long wood screws AA to attach the fan housing A to the ceiling joist If spacing...

Страница 7: ...wires back into the wiring box housing Reattach the wiring box cover CAUTION If the house electrical wires do not match the colors from the fan wiring diagram on page 4 you must determine what each ho...

Страница 8: ...Measure the opening to ensure it is large enough to accommodate the new fan housing A 10 1 4 in x 10 1 4 in 1 11 10 9 8 7 6 5 4 3 Enlarging the ceiling opening optional If this fan is not replacing a...

Страница 9: ...Allow for the thickness of the ceiling board used in your application Do not flush mount to the joist The flange should be flush with the ceiling board If spacing between joists is 12 in apart use 4 l...

Страница 10: ...wiring diagram on page 4 14 AWG is the smallest conductor that should be used for branch circuit wiring Carefully push the connected wires back into the wiring box housing Reattach the wiring box cov...

Страница 11: ...he grille B by pinching the mounting springs and inserting into the narrow rectangular slots in the fan housing A Humidity Sensing Operation 1 Using full speed mode Move the wall switch to the ON posi...

Страница 12: ...size ducting to reduce fan noise The fan body is not attached securely Be sure the fan is securely attached to the ceiling joists The fan is not clearing humidity from the room There is insufficient...

Страница 13: ...CUIDADO VENTILADOR DE BA O CON DETECTOR DE HUMEDAD Necesita ayuda Llame a nuestra l nea gratuita al 877 319 3757 7 30 a m a 4 30 p m CST para obtener asistencia adicional o servicio HOMEWERKS COM Mod...

Страница 14: ...ucir el riesgo de incendio y extraer el aire de manera adecuada aseg rese de ventilar el aire hacia el exterior No extraiga el aire en espacios dentro de paredes o techos o en ticos entrepisos o garaj...

Страница 15: ...to como parte de un reclamo sobre la garant a deben ser pagados por el cliente P ngase en contacto con el Servicio al Cliente llamando al 1 877 319 3757 de lunes a viernes de 7 30 a m a 4 30 p m hora...

Страница 16: ...s necesarios para la instalaci n de su ventilador de ba o est n incluidos Sin embargo la mayor a est n disponibles en su tienda de art culos del hogar o ferreter a local Diagrama de cableado ADVERTENC...

Страница 17: ...adro el ctrico CONTENIDO DEL PAQUETE Pieza Descripci n Cantidad A Carcasa del ventilador 1 B Rejilla 1 MATERIALES INCLUIDOS NOTA Los materiales no se ilustran en tama o real Pieza Descripci n Cantidad...

Страница 18: ...al ras con la tabla del techo Si el espacio entre las vigas es de 12 pulg use 4 tornillos para madera largos AA para instalar la carcasa del ventilador A en la viga del techo Si el espacio entre las...

Страница 19: ...ectados de nuevo en la carcasa de cableado Vuelva a colocar la cubierta de cableado PRECAUCI N Si los cables el ctricos e la casa no coinciden con los colores enumerados en la p gina 18 debe determina...

Страница 20: ...e de que sea suficientemente larga para acomodar la carcasa del ventilador nuevo A 10 1 4 pulg x 10 1 4 pulg 1 11 10 9 8 7 6 5 4 3 Alargar la abertura opcional Si este ventilador no est reemplazando u...

Страница 21: ...cuenta el espesor de la tabla del techo utilizada en su aplicaci n No monte al ras en la viga La brida debe estar al ras con la tabla del techo Si el espacio entre las vigas es de 12 pulg use 4 tornil...

Страница 22: ...p gina 18 14 AWG es el conductor m s peque o que se debe usar para el cableado de circuito de derivaci n Con cuidado empuje los cables conectados de nuevo en la carcasa de cableado Vuelva a colocar l...

Страница 23: ...onando los resortes de montaje e insert los en las ranuras rectangulares estrechas en la carcasa del ventilador A Operaci n del detector de humedad 1 Modo de velocidad completa Mueva el interruptor de...

Страница 24: ...o recomendado para reducir el ruido del ventilador La carcasa del ventilador no est instalada de forma segura Aseg rese de que el ventilador est instalado de forma segura en las vigas del techo El ve...

Отзывы: