66
Configuration menu
6.7
Offset temperature
As the temperature is measured on the radiator
thermostat, the temperature distribution can vary
throughout a room. To adjust this, a temperature offset
of ±3.5 °C can be set. If a nominal temperature of e.g.
20 °C is set but the room presents with only 18 °C, an
offset of -2.0 °C needs to be set. An offset temperature
of 0.0° is set in the factory settings. To adjust the offset
temperature, proceed as follows:
• Press and hold down the menu button
(E)
to
open the configuration menu.
• Select “Offset” via the plus and minus buttons
(C
+ F)
in the menu.
• Confirm with the menu button.
• Select the desired offset temperature using the
plus or minus button and confirm with the menu
button.
To confirm, the temperature flashes twice and the device
changes back to the standard display.