12 Other notes on operation
If the device reaches too high a temperature during
operation (due to insufficient air circulation, for
example), the load will first of all be reduced by
lowering the brightness. If the overtemperature
persists, the load will be disconnected.
If the actuator is operating via the HomeMatic
central control unit (CCU), please note that the
central control unit will not be informed in the
event of a load failure.
13 Technical data
Device designation:
HM-LC-Dim1T-FM
Power supply:
230 V / 50 Hz
Minimum load:
10 VA
Maximum current:
40 mA
Effective installed load:
180 VA
Standby consumption:
1 W
Dimming procedure:
Reverse phase
control
Radio frequency:
868,3 MHz
Receiver class:
SRD Class 2
Maximum transmit power:
10 mW
Typ. open air range:
100 m
Degree of protection:
IP20
Protection class:
II
Ambient temperature:
+5°C to +35°C
Dimensions (W x H x D):
53 x 53 x 30 mm
Weight:
43