30
31
relates to resistive loads! Please do not exceed
the capacity specified for the actuator.
The dimmer is only suitable for light bulbs and
high-voltage and low-voltage halogen lamps
with electronic transformers! Please only
connect lamp loads to the dimmer, and not
televisions, computers, motors etc.
Exceeding this capacity could lead to the
destruction of the device, fires or electric
shocks.
Before connecting the actuator is connected,
remove the fuse from the fuse box.
The dimmer contains a thermal cut-off. Please
note that if a small amount of heating occurs
the lamps and luminaires will be dimmed, and
in the event of overheating the loads will be
switched off altogether.
The device has not been designed to support
safety disconnection. The load is not isolated
from the mains.
If the dimmer is being operated with electronic
transformers, only those which meet the
requirements of DIN EN 61347-1 (VDE 0712-
30, Part 1) along with DIN EN 61047 (VDE
0712-25, Part 2) may be used.
To avoid electric shock, disconnect the mains
voltage prior to starting work on the device (trip
the miniature circuit-breaker).
Noncompliance with the installation instructions
can cause fire or introduce other hazards
(see
also chapter 6 Installation on page 34).
3 Function
The device is a reverse phase control dimmer for
installing in flush-mounted boxes. A reverse phase
control dimmer makes it possible to dim normal
incandescent lamps, dimmable energy-saving lamps,
high-voltage halogen lamps and low-voltage halogen
lamps with an electronic transformer. The actuator
controls connected loads in accordance with the
wireless commands it receives. Commands are
transmitted by actuating buttons or remote controls,
Содержание HM-LC-Dim1T-FM
Страница 26: ...50 51...