Installation of electrical installation material;
•
Type of supply network (TN system, IT system,
TT system) and the resulting connecting
conditions (classical zero balancing, protective
earthing, required additional measures etc.).
Installation may only take place in normal commercial
switch boxes (device boxes) in accordance with DIN
49073-1.
When installing many flush-mount actuators in
installation boxes that are one above the other
or adjacent to one another (connected or not),
the total switching current of 16 A is not to be
exceeded!
The installation of the actuator that is described is
shown in the following connection diagram.
Connect the actuator to L and N to obtain a power
supply.
Phase for pushbuttons is provided at the pushbutton
input. Route the switched phase to the consumer.
There are no controls on the device itself. A
pushbutton must be connected (even if it is only
temporary) for direct teach-ins without the HomeMatic
central control unit.
The control input is switched with mains
voltage. Only pushbuttons and cables that are
rated for mains voltage may be used! Only
connect pushbuttons at the input, not switches!
This would make the device malfunction!
Before installation, please note the serial
number on the device (10 digits, beneath
barcode) and the exact installation location so
that you can set up the device later via the user
interface of the HomeMatic central control unit.
HM-LC-Dim1T-FM
L
N
PE
1
1