background image

31

30

For purchases made in Iowa:

This form must be signed and dated by the buyer and seller prior to consummation of 
this sale. This form should be retained on fi le by the seller for a minimum of two years.

Buyer: 

 

Seller:

Name 

 

Name

Address 

 

Address

City 

 

City

State 

Zip 

State 

Zip

Signature 

Date 

Signature 

Date

Para compras hechas en Iowa:

Este formulario debe ser fi rmado y fechado por el comprador y el vendedor antes de completar 
esta venta. Este formulario debe archivarlo el vendedor por un período mínimo de dos años.

Comprador: 

 

Vendedor:

Nombre 

 

Nombre

Dirección 

 

Dirección

Ciudad 

 

Ciudad

Estado 

Código Postal 

Estado 

Código Postal

Firma 

Fecha 

Firma 

Fecha

Especificaciones Técnicas

Flujo: 2 galones por día (7.5 litros)
Capacidad: 40 galones (151 litros)
Vida Normal de Bombilla: 10 años
Clasificaciones Eléctricas: 120 Vac @ 15 Watts
Temperatura de funcionamiento: 50˚ - 85˚ F (10˚ – 29˚ C) 

Nota - No se hace ninguna garantía por el uso con agua en temperaturas 

más altas o más bajas.  

Por favor refiérase en otra parte en este Manual de instrucciones para el 

acondicionamiento apropiado, uso y exigencias del cuidado.

Precio al por menor sugerido para el Filtro de reemplazo  

RWS-1FL:  $8.00
Para comprar el filtro de reemplazo,  

ver www.homedics.com/restore

Compras hechas en Iowa

Содержание Restore IB-RWS100A

Страница 1: ...do por el fabricante daños durante el transporte robo descuido vandalismo condiciones climáticas pérdida de uso en el período durante el cual el producto está en una instalación de reparación o a la espera de piezas o reparación o cualquier otra condición sin importar cual sea que se encuentre fuera del control de HoMedics Esta garantía es válida únicamente si el producto es comprado y operado en ...

Страница 2: ...efore cleaning or filter replacement ALWAYS operate indoors The appliance blocks all harmful Ultraviolet UV light when operated according to instructions 2 The reservoir lid and spout lid must be fully seated during operation Use this appliance only for its intended use as described in this manual DO NOT use attachments not recommended by HoMedics Specifically any attachments not provided with the...

Страница 3: ...ds without adult supervision DO NOT attempt to open the product No user serviceable parts are inside the Appliance Use only factory authorized replacement parts For household use only DO NOT use product for any other use DO NOT use the product if any leaks develop DO NOT use with hot water as it may damage the product The UV lamp contains a small amount of mercury Please dispose of in accordance t...

Страница 4: ... juice baby formula ice pet bowls and more Note You may store the pitcher in the refrigerator Re purify water if it sits out for more than 2 days 7 6 fig 3 fig 4 fig 5 fig 6 Instructions for Use This plug will fit in an outlet only one way If it does not fit contact a qualified electrician to install the proper outlet Do not modify the plug in any way Getting Started PITCHER WITH FILTER 1 Wash the...

Страница 5: ...mption level a full pitcher capacity is 8 cups If your consumption changes you can change the setting at any time and the filter life will automatically adjust A filter will last approximately 2 months with average household use NOTE For maximum efficiency do not purify more than 2 gallons per day Maintenance To Clean Pour out water To ensure that the UV lamp assembly introduces the proper dose of...

Страница 6: ...n a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Note The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment Such modifications could void the user authority to operate the equipment Troubleshooting The UV will not activate Please make sure the fo...

Страница 7: ...on requirements under NSF ANSI Standard 53 as tested by PACE Analytical Services Inc Substance Influent Challenge Concentration Maximum Permissable Concentration Average Actual Reduction NSF 53 1988 Lead pH 7 5 0 150 mg L 10 0 020 mg L 98 7 Meets the lead reduction requirements under NSF ANSI Standard 53 1988 as tested by PACE Analytical Services Inc This system has been independently tested by PA...

Страница 8: ...Technical Specifications Flow 2 gallons per day 7 5 liters Capacity 40 gallons 151 liters Typical Bulb Life 10 years Electrical Ratings 120 Vac 15 Watts Operating Temperature 50 85 F 10 29 C Note No warranty is made for use with water at higher or lower temperatures Please refer elsewhere in this Instruction Manual for the proper conditioning use and care requirements Suggested Retail for Replacem...

Страница 9: ...conditions loss of use during the period the product is at a repair facility or otherwise awaiting parts or repair or any other conditions whatsoever that are beyond the control of HoMedics This warranty is effective only if the product is purchased and operated in the country in which the product is purchased A product that requires modifications or adoption to enable it to operate in any other c...

Страница 10: ... bajo techo Cuando funciona según las instrucciones el aparato bloquea toda la luz ultravioleta dañina UV 18 El depósito la tapa y la tapa del pico deben estar totalmente asentados durante el funcionamiento Utilice este artefacto sólo para el uso para el cual fue diseñado y como se describe en este manual No use accesorios no recomendados por HoMedics particularmente accesorios no proporcionados c...

Страница 11: ... sin la supervisión de un adulto NO intente abrir el producto Dentro del aparato no hay piezas que necesiten servicio por parte del usuario Sólo use piezas de repuesto autorizadas de fábrica Sólo para uso doméstico NO use este producto por ningún otro uso No use el producto si desarrolla alguna pérdida NO lo use con agua caliente puesto que puede dañar el producto La lámpara UV contiene una pequeñ...

Страница 12: ...para bebés hielo tazón de mascotas y más Nota Usted puede guardar la jarra en el refrigerador Purifique de nuevo el agua si la guarda por más de 2 días y esto no afecta el rendimiento 23 Instrucciones para el uso Este enchufe calzará en el tomacorriente en un solo sentido Si no calza póngase en contacto con un electricista calificado para instalar un tomacorriente adecuado No cambie el enchufe de ...

Страница 13: ...rificar el agua Para purificar el agua presione el botón PURIFY Si la luz PURIFY parpadea ver la sección de Solución de problemas Alarma Automática del Filtro Esta función le alerta cuando es tiempo de sustituir su filtro Si el indicador de sustitución del filtro está iluminado Reemplace el filtro por uno nuevo Ver la sección Para Empezar por instrucciones detalladas Presione y sostenga el botón d...

Страница 14: ...está conectado el receptor Consulte al distribuidor o un técnico de radio TV con experiencia para ayuda Nota el fabricante no es responsable de ninguna interferencia de radio o televisor causada por modificaciones no autorizadas a este equipo Tales modificaciones pueden anular la autoridad del usuario para hacer funcionar el equipo Resolución de problemas La luz UV no se activa Por favor asegúrese...

Страница 15: ...áxima influente Concentración máxima aceptable Reducción real promedio NSF 42 Efectos estéticos Cloro sabor y olor 2 mg L 10 1 mg L 98 9 Zinc 10 mg L 10 5 mg L 86 2 NSF 53 Efectos sobre la salud Benceno 0 015 mg L 10 0 005 mg L 94 4 Cadmio pH 6 5 0 03 mg L 10 0 005 mg L 91 8 Cadmio pH 8 5 0 03 mg L 10 0 005 mg L 89 9 Cobre pH 6 5 3 mg L 10 1 3 mg L 89 7 Cobre pH 8 5 3 mg L 10 1 3 mg L 77 9 Lindano...

Страница 16: ...dor Vendedor Nombre Nombre Dirección Dirección Ciudad Ciudad Estado Código Postal Estado Código Postal Firma Fecha Firma Fecha Especificaciones Técnicas Flujo 2 galones por día 7 5 litros Capacidad 40 galones 151 litros Vida Normal de Bombilla 10 años Clasificaciones Eléctricas 120 Vac 15 Watts Temperatura de funcionamiento 50 85 F 10 29 C Nota No se hace ninguna garantía por el uso con agua en te...

Отзывы: