CARE, MAINTENANCE & CLEANING

1. Do not disconnect the tubing or remove the inflation bulb from the arm cuff.
2. Clean the blood pressure monitor body and cuff carefully with a slightly damp,

soft cloth. Do not press. Do not wash cuff or use chemical cleaner on it. Never
use thinner, alcohol or petrol (gasoline) as cleaner.

3. Leaky batteries can damage the unit. Remove the batteries when the unit will

not be used for a long time.

4. If the unit is stored near freezing, allow it to acclimate to room temperature

before use.

5. This blood pressure monitor is not field service-able. You should not use any

tool to open the device nor should you attempt to adjust anything inside the
device. If you have any problems with this device, please contact HoMedics
Customer Service (contact information can be found on the guarantee page).

6. Do not immerse the unit in water as this will result in damage to the unit.
7. Do not subject the monitor and cuff to extreme temperatures, humidity,

moisture, and direct sunlight. Protect from dust.

8. Do not fold the cuff and tubing tightly.
9. Do not disassemble the monitor or cuff. If in need of repair, refer to the warranty

section of this manual.

10. Do not subject the monitor to extreme shocks (do not drop on floor).
11. Do not inflate the cuff unless wrapped around arm.
12. Do not wrap the cuff around body parts other than your arm.
13. Do not drop or insert any object into any opening or hose.
14. This monitor may not meet its performance specifications if stored or used

outside of these temperature and humidity ranges:
• Storage Environment

• Operating Environment

Temperature:

Temperature:

-10°C~60°C (14°F~140°F)

10°C ~40°C (50°F~104°F)

Humidity:

Humidity:

10~90% RH max.

40~85% RH max.

21

IMPORTANT NOTES REGARDING YOUR BLOOD
PRESSURE MEASUREMENT

• Take your reading in a comfortable environment as measurements can be

affected by hot or cold temperatures. Take your blood pressure at normal body
temperature.

• Do not move or talk during measurement as this can elevate readings.
• Do not move or cross legs during measurement. Keep feet flat on floor.
• Do not touch cuff or monitor during measurement

procedure.

• It is suggested that you take your measurements

at the same time each day and use the same arm for consistency.

• Users should wait a minimum of 5 minutes before taking additional

measurements. More time may be necessary depending upon your physiology.

• The measurement results that users receive are for reference only. If users have

any blood pressure concerns, please consult a doctor.

• Once inflation reaches 300 mmHg, the unit will deflate automatically for safety

reasons.

• This product is not suitable for people

with arrhythmias.

• This device may have difficulty determining the proper blood pressure for users

with diabetes, poor circulation of blood, kidney problems, or for users who have
suffered a stroke.

RECALIBRATION SERVICE

All digital blood pressure monitors require recalibration in order to
ensure continued accuracy.

This monitor does not require recalibration for 2 years under normal usage
conditions (approximately 3 times per day), at which time your monitor will
display “

”. The unit should also be recalibrated if the monitor sustains damage

due to blunt force (such as dropping) or exposure to fluids or extreme hot or cold
temperature changes.

Please fill in date of first use
(Recalibration is recommended after 2 years.)

To recalibrate your blood pressure monitor, please contact HoMedics Customer
Service on Tel: + 44 (0) 1732 378557 or Email: [email protected]

20

Содержание BPS-420

Страница 1: ...Instruction Manual BPS 420 0GB Manual Inflate Blood Pressure Monitor ...

Страница 2: ...ORMATION Name Function of Each Part 8 Display Explanations 9 Installing Batteries 11 Date Time Set Procedure 12 Using The Arm Cuff 13 Measurement Procedure 16 Risk Category Indicator 18 Recalling Values from Memory 19 Clearing Values from Memory 19 Important Notes Regarding Your Blood Pressure Measurement 20 Recalibration Service 20 Care Maintenance Cleaning 21 Troubleshooting 22 Specifications 23...

Страница 3: ...The device contains sensitive electronic components Avoid strong electrical or electromagnetic fields in the direct vicinity of the device e g mobile telephones microwave ovens These may lead to temporary impairment of measurement accuracy Use blood pressure monitor only for its intended use Do not wrap the cuff around body parts other than your arm This unit is intended for use in measuring the b...

Страница 4: ...ell you your normal blood pressure range as well as the point at which you will be considered at risk For reliable monitoring and reference of blood pressure keeping long term records is recommended 6 7 HOW THIS BLOOD PRESSURE MONITOR WORKS This manual inflate digital blood pressure monitor provides systolic pressure diastolic pressure and pulse readings quickly and easily Once the cuff is inflate...

Страница 5: ...olic Pressure Date Time Indicator Pulse Rate 9 LCD Display Battery Cover Located on bottom of unit Memory Recall Button START STOP Button Cuff Tube Date Time Set Buttons Located on back of unit Arm Cuff Inflation Bulb Name Function of Each Part 8 ...

Страница 6: ...push in the top end of the battery door 11 Inflation Symbol Appears when cuff requires inflation Deflation Symbol Appears when cuff is deflating Weak Battery Symbol Appears when batteries should be replaced Pulse Symbol Shows the pulse rate per minute Risk Category Indicator Compares readings against blood pressure guidelines set by the JNC7 standard See page 18 for more information If any of the ...

Страница 7: ... the Arrow falls outside of the Solid Color Line you need a cuff with another circumference Contact HoMedics Consumer Relations on tel 44 0 1732 378557 or email cservice homedics co uk 13 Press the button Blinking date Increasing date Confirm the entry Repeat process to set month and time Date Time Set Procedure 1 To adjust the date time press the Set button located on the back of the monitor 2 Th...

Страница 8: ...be is not kinked 15 A R R O W M U S T FA LL W IT H IN Y E LL O W B A N D D ring End of cuff Felt Material on the outside of cuff 2 Plug the cuff tube into the left side of the unit Cen ter tub e ove r mid dle of arm Insert plug here 3 Open the arm cuff so that your arm may be placed through it 4 Remove tight fitting clothing from around your upper left arm 1 If the cuff is not assembled pass the e...

Страница 9: ...OP button to turn the unit off 2 To interrupt the measurement you may press the START STOP recommended MEM or Date Time Set buttons The cuff will deflate immediately after a button is pressed 17 Main Artery NOTE If it is not possible to fit the cuff to your left arm it can also be placed on your right arm However all measurements should be made using the same arm To use on the right arm you must p...

Страница 10: ...proximately 5 seconds then the data will be erased automatically 19 No Symbol Risk Category Indicator This unit conforms to the JNC7 blood pressure standard classifying blood pressure ranges into 4 stages This unit is equipped with an innovative blood pressure classification indicator which visually indicates the assumed risk level normal prehypertension stage 1 hypertension or stage 2 hypertensio...

Страница 11: ... 104 F Humidity Humidity 10 90 RH max 40 85 RH max 21 IMPORTANT NOTES REGARDING YOUR BLOOD PRESSURE MEASUREMENT Take your reading in a comfortable environment as measurements can be affected by hot or cold temperatures Take your blood pressure at normal body temperature Do not move or talk during measurement as this can elevate readings Do not move or cross legs during measurement Keep feet flat o...

Страница 12: ...dics Customer Service Under no circumstance should you disassemble or attempt to repair the unit by yourself Contact information for HoMedics Customer Service Department can be found on the guarantee page SYMPTOMS POSSIBLE CAUSES CORRECTION Unit does not turn on when the START STOP button is pushed Batteries have run down Replace them with two new AA alkaline batteries Battery polarities have been...

Страница 13: ...amage caused by misuse or abuse accident the attachment of any unauthorised accessory alteration to the product or any other conditions whatsoever that are beyond the control of HoMedics This guarantee is effective only if the product is purchased and operated in the UK EU A product that requires modification or adaptation to enable it to operate in any country other than the country for which it ...

Отзывы: