background image

14

15

Troubleshooting

The unit won't  
turn on

• The unit is not    
  plugged in

• Plug the unit in

• The filters are dirty

• Clean or replace the 
  nano-coil filter and/ 
  or clean the pre-filter

• The front or rear grill is  

  

  blocked by foreign objects

• Remove any obstacles  
  or check the pre-filter  
  and clean if needed

• Nano-coil filter is  
  incorrectly installed or   
  out of place

• Properly install the  
  nano-coil filter

• Replace the 
  nano-coil filter

• The plastic bag is still on  
  the VOC/Odor filter

• Remove the plastic bag

• Rear cover is not  
  completely attached 

• Make sure rear grill is   
  completely engaged

• The unit has been running  
  for over 2,000 hours

• Remote control battery 
  has run down

• Replace the battery

No air flow or 
noticeable  
cleaning effect

Problem

Possible Cause

Solution

Clean Filter Indicator

This air cleaner is equipped with a CLEAN FILTER indicator to let you know when it 
is time to clean the Nano-Coil filter, about every 732 hours of use. When the Nano-
Coil filter is ready to be cleaned, the CLEAN FILTER indicator will light up on the 
control panel.
Once the Nano-Coil filter has been cleaned, press and hold the CLEAN FILTER button 
until it beeps to reset the filter indicator.
We recommend replacing your VOC filter, if you choose to use it, when you replace 
your Nano-Coil filter (about every 18 months, with regular maintenance).
To purchase a Nano-Coil replacement filter, model # AR-NCFL1, go back to the retailer 
(where you purchased your air cleaner) or visit www.homedics.com. Replacement 
VOC filter, model # PP-ARNC01VOC, can also be purchased  
at www.homedics.com. 

8. Place the tabs at the bottom of the    
  grill plate into the base of the unit.  
  See Fig. 19

9. Hold engaged bottom of the grill  

 

  plate in place and push the top of the   
  grill plate back toward the unit until    
  the release tabs at the top of the grill    
  click back into place. See Fig. 20

Fig. 19

Fig. 20

TABS

TABS

Cleaning and Maintenance

We recommend that the air cleaner be cleaned at least once a month and before storage.
1. Turn the air cleaner OFF and unplug it from the outlet
2. Use a dry cloth to clean the external surfaces of the air cleaner
3. The grill plate may be cleaned with a damp cloth or the brush attachment of  
  your vacuum cleaner.

DO NOT USE WATER, WAX, POLISH, OR ANY CHEMICAL SOLUTION

Содержание AR-NC01

Страница 1: ...eñado fabricado aprobado y o autorizado o la reparación de productos dañados por estas modificaciones no están cubiertos bajo esta garantía LA GARANTÍA AQUÍ ESTABLECIDA SERÁ LA ÚNICA Y EXCLUSIVA GARANTÍA NO HABRÁ NINGUNA OTRA GARANTÍA EXPRESA NI IMPLÍCITA INCLUYENDO NINGUNA GARANTÍA DE COMERCIALIZACIÓN O APTITUD NI NINGUNA OTRA OBLIGACIÓN POR PARTE DE LA COMPAÑÍA CON RESPECTO A PRODUCTOS CUBIERTOS...

Страница 2: ... whenever the air cleaner is left operating and unattended Always unplug the air cleaner when not in use Do not operate the air cleaner with a damaged cord or plug or after the air cleaner malfunctions has been dropped or damaged in any manner Return to HoMedics Consumer Relations for examination electrical or mechanical adjustment or repair This air cleaner is not intended for use in bathroom lau...

Страница 3: ... tab for grounding screw extending from the temporary adapter must be connected to a permanent ground such as a properly grounded outlet box cover and it must be held in place by a metal screw Fig 3 The temporary adapter should be used only until a properly grounded outlet Fig 4 can be installed by a qualified electrician Pre Filter Captures large particles and fibers Nano Coil Filter Cleanable sp...

Страница 4: ...e tabs toward the outside of the unit See Fig 1 2 Pull the grill away from the body until the tabs at the bottom of the grill plate easily slide away from the unit See Fig 2 3 3 The pre filter and nano coil filter will be installed already To install the VOC Odor filter optional remove the VOC Odor filter from the plastic bag Place the VOC filter into the unit flush against the pre filter secured ...

Страница 5: ...e Batteries may explode or leak Use only the size and type of batteries specified When installing batteries observe proper polarity Improper installation of batteries may cause damage Operating Instructions 1 On Off and Speed Settings 1 To turn the air cleaner on press the ON OFF button When the air cleaner is on the LED light will be lit and the air cleaner will start to operate on LOW speed 2 Th...

Страница 6: ...g out from the center hub See Fig 10 4 Use the brush attachment with your vacuum cleaner Run the attachment along both sides of the nano coil filter taking care not to dislodge the combs See Fig 11 5 Replace the nano coil filter Make sure to align the center of the filter handle with the center hub Filter handle should be vertical Be sure the post on the center hub comes through the hole on the fi...

Страница 7: ...u are using the VOC filter remove it by sliding out of the 4 clips See Fig 17 4 Remove the pre filter by gently pulling it off and away from the 4 posts See Fig 18 5 Use the brush attachment with your vacuum cleaner Run the attachment along both sides of the pre filter See Fig 11 6 Replace the pre filter by pushing the 4 loops of the filter onto the 4 posts of the grill See Fig 18 7 If you are usi...

Страница 8: ...p on the control panel Once the Nano Coil filter has been cleaned press and hold the CLEAN FILTER button until it beeps to reset the filter indicator We recommend replacing your VOC filter if you choose to use it when you replace your Nano Coil filter about every 18 months with regular maintenance To purchase a Nano Coil replacement filter model AR NCFL1 go back to the retailer where you purchased...

Страница 9: ...or authorized or repair of products damaged by these modifications is not covered under this warranty THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY THERE SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS OR ANY OTHER OBLIGATION ON THE PART OF THE COMPANY WITH RESPECT TO PRODUCTS COVERED BY THIS WARRANTY HOMEDICS SHA...

Страница 10: ... cuando el limpiador de aire se deje funcionando sin supervisión Desenchufe siempre el limpiador de aire cuando no lo esté usando No haga funcionar el limpiador de aire con un cable o un enchufe dañado o después de que limpiador de aire no funcione adecuadamente se haya caído o dañado de cualquier manera Devuelva a Atención al consumidor de HoMedics para que lo examinen lo ajusten eléctrica o mecá...

Страница 11: ...exión a tierra con una tercera clavija de conexión a tierra Fig 1 Este enchufe únicamente entra en un tomacorriente del tipo de conexión a tierra Si el enchufe no entra en el tomacorriente póngase en contacto con personal calificado para que instale el tomacorriente adecuado No modifique el enchufe de ningún modo Si en su casa no hay un tomacorriente con conexión a tierra puede utilizar un adaptad...

Страница 12: ...as de liberación hacia el exterior de la unidad Vea la Fig 1 2 Retire la rejilla del cuerpo hasta que las lengüetas de la parte inferior de la placa de la rejilla se deslicen fácilmente fuera de la unidad Vea las Fig 2 y 3 3 El prefiltro y el filtro de nanobobinas ya estarán instalados Para instalar el filtro de olores VOC opcional retírelo de la bolsa plástica Coloque el filtro VOC en la unidad p...

Страница 13: ...entilador Temporizador Si el temporizador se fija en 4 horas para situaciones la luz de fondo blanca de numer 4 estará encendido durante 3 segundos y luego se apagará Instrucciones de uso 1 Encendido apagado y modos de velocidad 1 Para encender el limpiador de aire presione el botón de encendido apagado ON OFF Cuando el limpiador de aire esté encendido la luz LED se encenderá y el limpiador de air...

Страница 14: ... núcleo central Vea la Fig 10 4 Use el accesorio de cepillo con su aspiradora Pase el accesorio por ambos lados del filtro de nanobobinas con cuidado para no desprender los peines Vea la Fig 11 5 Vuelva a colocar el filtro de nanobobinas Asegúrese de alinear el centro del mango del filtro con el núcleo central El mango del filtro debe estar en posición vertical Asegúrese de que la varilla del núcl...

Страница 15: ... 18 3 Si está usando el filtro VOC retírelo deslizándolo fuera de los 4 sujetadores Vea la Fig 17 4 Retire el prefiltro empujándolo suavemente hasta extraerlo de las 4 varillas Vea la Fig 18 5 Use el accesorio de cepillo con su aspiradora Pase el accesorio por ambos lados del prefiltro Vea la Fig 11 6 Vuelva a colocar el prefiltro empujando los 4 lazos del filtro sobre las 4 varillas de la rejilla...

Страница 16: ...r hacia la unidad hasta que las lengüetas de liberación de la parte superior de la rejilla vuelvan a su lugar con un clic Vea la Fig 20 Pestañas Pestañas Diagnóstico y resolución de problemas La unidad no enciende La unidad no está enchufada Enchufe la unidad Los filtros están sucios Limpie o reemplace el filtro de nanobobinas y o limpie el prefiltro La rejilla delantera o trasera está bloqueada p...

Отзывы: