Safety Information

We have provided many important safety messages in this manual 
and on your appliance. Always read and obey all safety messages.

DANGER:

 This symbol alerts you to a potential hazard, 

that if not avoided, will result In death or serious injury.

WARNING:

This symbol alerts you to a potential hazard, 

that if not avoided, could result In death or serious Injury.

CAUTION:

 This symbol alerts you to a potential hazard, 

that if not avoided, may result in minor or moderate injury.

IMPORTANT SAFETY INSTRUCTIONS

To reduce the risk of fire, electrical shock or injury when using your 
air conditioner, follow these basic precautions:

 

Plug into a grounded 3-prong outlet. 

 

Do not remove ground prong.

 

Do not use an adapter.

 

Do not use an extension cord.

 

Unplug air conditioner before servicing.

 

Use two or more people to move and install air conditioner.

DISPOSING OF THE UNIT

 

Before throwing out the device, it is necessary to remove the 
battery cells and dispose or recycle them properly.

 

When you need disposal of the unit consult our dealer. If pipes 
are removed incorrectly, refrigerant may blow out and come into 
contact with your skin, causing injury. Releasing refrigerant into 
the atmosphere also damages the environments.

 

Please recycle or dispose of the product packaging material in 
an environmentally responsible manner.

 

Never store or ship the air conditioner upside down or sideways 
to avoid damage to the compressor.

 

This appliance is not intended for use by persons (including 
children) with reduced physical, sensory or mental capabilities, 
or lack of experience and knowledge, unless they have been 
given supervision or instruction concerning use of the appliance 
by a person responsible for their safety. Children should be 
supervised to ensure that they do not play with the appliance.

 

The wiring diagram is shown on nameplate on the air 
conditioner.

WARNING:

 Risk of Fire or Explosion. This unit contains 

flammable refrigerant.

Additional safety precautions must be followed.

 

Do not use means to accelerate the defrosting process 
or to clean, other than those recommended by the 
manufacturer.

 

The appliance shall be stored in a room without 
continuously operating ignition sources (for example: 
open flames, an operating gas appliance or an operating 
electric heater).

 

Do not pierce or burn refrigerant tubing. Be aware that 
refrigerants may not contain an odor.

 

Keep ventilation openings clear of obstruction.

 

The maximum refrigerant charge amount is shown on 
nameplate on the air conditioner.

 

When handling, installing, and operating the appliance, 
care should be taken to avoid damage to the refrigerant 
tubing.

 

Do not drill holes in the unit.

 

Maintenance, cleaning, and service should only be 
performed by technicians properly trained and qualified 
in the use of flammable refrigerants.

 

Dispose of air conditioner in accordance with Federal 
and Local Regulations. Flammable refrigerants require 
special disposal procedures. Contact your local 
authorities for the environmentally safe disposal of your 
air conditioner.

 

The appliance shall be stored so as to prevent 
mechanical damage from occurring.

Содержание 1007086606

Страница 1: ...hance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Vissani USE AND CARE GUIDE WINDOW AIR CONDITIONER Questions problems m...

Страница 2: ...g requirement 4 Power Supply Cord 4 Pre Installation 4 Planning Installation 5 Hardware Included 6 Unpack the Air Conditioner 7 Location Requirements 7 Window Installation 9 If AC is Blocked by Storm...

Страница 3: ...compressor This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given sup...

Страница 4: ...qualified electrical installer It is the customer s responsibility To contact a qualified electrical installer To assure that the electrical installation is adequate and conforms to the Nation Electr...

Страница 5: ...oper operation The power supply cord must be replaced if it fails to trip when the test button is pressed or fails to reset Do not use the power supply cord as an off on switch The power supply cord i...

Страница 6: ...C CC DD DD EE EE FF FF II II KK KK JJ JJ GG GG Part Description Quantity AA Adhesive seal 2 BB Foam seal 1 CC Sealing sponge 1 DD Lock frame for wooden windows 2 EE Lock frame for vinyl Clad windows 2...

Страница 7: ...ng alcohol flammable fluids or abrasive cleaners to remove tape or glue These products can damage the surface of your air conditioner Handle the air conditioner gently Remove top rail II from the pack...

Страница 8: ...verning codes and ordinances Check the location where air conditioner will be installed Proper installation is your responsibility Make sure you have everything necessary for correct installation The...

Страница 9: ...he electrical outlet must be within reach of the power cord Follow the dimensions in the table and illustration for your model Models A B 5KBTU 12 2 5 inch 315 mm min 22 inch 559 mm 37 4 5 inch 960 mm...

Страница 10: ...and then bottom of right hand curtain housing A in top and bottom curtain rails B on air conditioner B B B A A A A A A B B B Slide the curtain housing into the channels as far as it will go Repeat ab...

Страница 11: ...el Do not block the louvers on the outside of the air conditioner Center air conditioner in window Lower the window sash A behind the top rail to hold cabinet in place Keep a firm grip on the air cond...

Страница 12: ...inst the glass of the upper window A B Use a 1 8 inch 3 mm drill bit to drill a starter hole through the hole in the top rail Attach top channel to window sash with one 3 4 inch 19 mm screw to secure...

Страница 13: ...6 89 6 F 17 32 C 80 RH Operating your air conditioner properly helps you to obtain the best possible results This section explains proper air conditioner operation 1 Power Press the power button to tu...

Страница 14: ...er cool settings will provide higher room temperature NOTE The controls featured in this manual are representative of many available models Your model may offer slightly different features 5 Changing...

Страница 15: ...he filter out from the right hand side of the front panel A Use a vacuum cleaner to clean the air filter A If the air filter is very dirty wash it in warm water with a mild detergent Do not wash the a...

Страница 16: ...d on the same circuit Unplug or relocate appliances that share the same circuit Time delay fuse or circuit breaker of the wrong capacity is be ing used Replace with a time delay fuse or circuit breake...

Страница 17: ...air conditioners are not designed to cool multiple rooms The filter is dirty or obstructed by debris Clean the filter The inside evaporator and outside condenser coils are dirty or obstructed by debri...

Страница 18: ...roblems missing parts Before returning to the store call Vissani Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 877 527 0313 HOMEDEPOT COM Retain this manual for future use...