5
HomewerksWW.com
Before removing your current ventilation unit, verify your switch box on the wall has the required
supply wires necessary for this installation. These supply wires are power/black and neutral/white
(refer to right side of wiring diagram below) at the switch. If you do not see both of these wires,
consult a licensed electrician.
Check area above installation location to be sure that wiring can run to the planned location and that
duct work can be run and the area is sufficient for proper ventilation.
Inspect duct work and wiring before proceeding with installation.
Before installation, provide inspection and future maintenance access at a location that will not interfere
with installation work.
You may need the help of a second person to install this fan; one person on the attic side and one on
the room side.
Note:
I
nstallation may vary depending on how the previous bath fan was installed. Supplies necessary
for the installation of your bath fan are not all included; however, most are available at your local
home improvement or hardware store.
DIMENSIONS REQUIREMENTS
Ceiling
Opening (L)
Ceiling
Opening (W)
Ceiling
Opening (H)
Housing
Dimension (L)
Housing
Dimension (W)
Housing
Dimension (H)
9-1/4 in.
9-1/4 in.
8-1/4 in.
9 in.
9 in.
7-13/16 in.
WIRING DIAGRAM
All wiring must be connected for full functionality. Do not use metal wall plate with switch.
ATTENTION:
The switch included with this ventilation
fan requires a neutral wire connection.
If a neutral line is not present, one must
be run by a qualified electrician.
NOTE:
This switch is intended to only
operate independently with this bath
fan. Connections to other electrical
fixtures are prohibited and could cause
electrical issues.
If you require assistance, please call
1-877-319-3757 before attempting
switch installation
.
House neutral/white
Power/black
Ground wire/green
Switch/black
Fan neutral/white
Switch/red
Fan
AC120V/60Hz
Green
Red
White
Black
PREPARATION