HOMEDEPOT.COM/HOMEDECORATORS
Please contact 1-800-986-3460 for further assistance
9
1
Disconnecting the propane hose
3
Replacing with the natural gas orifice
□
Disconnect the propane hose from the gas valve.
CAUTION:
Natural gas conversion must be performed
only by natural gas provider or service company.
□
Replace the propane orifice with the natural gas orifice, screw
the natural gas orifice with the bellows tightly, then connect
and tighten the natural gas orifice with the inlet tube.
□
2
Disconnecting the propane orifice
□
Unscrew and disconnect the propane orifice from the bellows.
□
Propane orifice (2.09 mm diameter size) is painted with a red
mark.
propane hose
propane orifice
propane orifice
bellows
bellows
natural gas orifice
inlet tube
bellows
gas valve
The natural gas orifice (4.18 mm diameter size) is painted with a
black mark.
Operation – Natural Gas Conversion