- 5 - 

in with current is to measure. 

4. 

Read current value on Digital Display. 

5. 

Additionally,  “10A”  function  is  designed  for 
intermittent use only. Maximum contact time 
of  the  test  leads  with  the  circuit  is  15 
seconds,  with  a  minimum  intermission  time 
of seconds between tests. 

 
RESISTANCE MEASUREMENT 

1. 

Red lead to “V

mA”. Black lead to “COM”. 

2. 

RANGE switch to desired OHM position. 

3. 

If the resistance being measured is connec- 
ted to a circuit, turn off power and discharge 
all capacitors before measurement. 

4. 

Connect  test  leads  to  circuit  being  mea- 
sured. 

5. 

Read resistance value on Digital Display. 

 
DIODE MEASUREMENT 

1. 

Red lead to “V

mA”, Black lead to “COM”. 

2. 

RANGE switch to “

” position. 

3. 

Connect the red test lead to the anode of the 
diode to be measured and black test lead to 
cathode. 

4. 

The  forward  voltage  drop  in  mV  will  be 
displayed. If the diode is reversed, figure “1” 
will be shown. 

 
TRANSISTOR hFE MEASUREMENT   

1. 

RANGE switch to the hFE position. 

Содержание DT830B

Страница 1: ...830B DIGITAL MULTIMETER READ AND UNDERSTAND THIS MANUAL BEFORE USING THE INSTRUMENT Failure to understand and comply with the WARNINGS and operating instructions can result in serious or fatal injurie...

Страница 2: ...y workshop DIYers and home applications SPECIFICATIONS Accuracies are guaranteed for 1 year 23 5 less than 80 RH DC VOLTAGE RANGE RESOLUTION ACCURACY 200mV 100uV 0 5 of rdg 3D 2000mV 1mV 20V 10mV 200V...

Страница 3: ...rdg 2D 10A 10mA 2 0 of rdg 10D 1 8 of rdg 2D OVERLOAD PROTECTION 500mA 250V fuse 10A range unfused MEASURING VOLTAGE DROP 200mV RESISTANCE RANGE RESOLUTION ACCURACY 200 100m 1 0 of rdg 10D 2000 1 20K...

Страница 4: ...ed is not known beforehand set switch to the highest range and reduce it until satisfactory reading is obtained 3 Connect test leads to device or circuit being measured 4 Turn on power of the device o...

Страница 5: ...ion 3 If the resistance being measured is connec ted to a circuit turn off power and discharge all capacitors before measurement 4 Connect test leads to circuit being mea sured 5 Read resistance value...

Страница 6: ...ent and blow almost always as a result of operator error If appears in display it indicates that the battery should be replaced To replace battery Fuse 500mA 250V remove the 2 screws in the bottom of...

Страница 7: ...7...

Страница 8: ...ttery the switch should be in the OFF position when the instrument is not in use 2 DISPLAY 3 digit 7 segment 0 5 high LCD 3 Common JACK Plug in connector for black negative test lead 4 V mA JACK Plug...

Отзывы: