TROUBLESHOOTING

AFTER GRILL HAS BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS

Possible Causes:

Possible Remedies: (Unplug stove 

fi

 rst when possible)

1. 

Grill is dirty, which restricts air

fl

 ow through the burnpot.

Follow all cleaning procedures in the maintenance section of the 

owner’s manual.

2. 

Burnpot holes are blocked.

Remove the burnpot and thoroughly clean it.

3. 

Blockage in air intake pipe.

Visually inspect the air intake that leads into the burnpot for foreign 

material.

4. 

Combustion blower is not spinning fast enough.

Clean fan blades and inspect bearings for wear. Ensure the fan is free 

of any obstructions.

5. Bad 

Pellets.

 

The brand of pellets or the batch of pellets that are being used may be 

of poor quality.  If possible, try a different brand of pellets.  You might also 
want to try a brand that is made from a different type of wood (softwood 
vs. hardwood).  Different woods have different characteristics when being 
burned.

GRILL ENTERS SHUTDOWN MODE UNEXPECTEDLY

Possible Causes:

Possible Remedies: (Unplug stove 

fi

 rst when possible)

1.  The convection blower is overheating and tripping the internal 

temperature shutoff.

Clean any dust off of the windings and fan blades.  If oiling the blower 

does not help, the blower may be bad.

2. 

The grill is being left on the highest setting for extended periods of 
time.

If operating the grill on the highest heat setting, the room temperature 

could increase enough and lead to potential overheating situations. If this 
happens, try operating at a lower heat setting. 

3. 

Fuel other than wood pellets is being burned in the stove.

This pellet grill is designed and tested to use cooking wood pellets.  

Check for signs of fuel other than wood pellets.  No other types of fuel 
have been approved for this pellet grill.  If there are signs of other types 
of fuel being used, stop using them immediately.

4. 

Power surge or brown out situation.

A power surge, spike, or voltage drop could cause the thermocouple 

to malfunction.  Use a surge protector

5. 

Thermocouple is malfunctioning.

If the other items check out OK, replace the thermocouple.

Error Codes

Possible Causes:

Possible Remedies: (Unplug stove 

fi

 rst when possible)

1. 

Error Code 1 - Over Temperature - The measured temperature has 
exceeded the overtemp set point.

Call Customer service (800) 750-2723.

2. 

Error Code 2 - No Start - The grill did not reach the warm condition 
set point before the timer expired (15 Min.)

Visually inspect the ignition system. Try to start the grill again. If the 

grill fails to start a second time call customer service (800) 750-2723.

3. 

Error Code 3 - Power Failure - The power failed while the grill was 
operating and the grill temperature was below the warm set point 
when power was returned.

Press the power and the prime button at the same time to resume 

standard operation.

11 

Содержание Smartfire PG-30

Страница 1: ...pection requirements in your area Save these instructions Manufactured By United States Stove Company 227 Industrial Park Road South Pittsburg TN 37380 Phone 800 750 2723 Part No 852076D Assembly and Operating Instructions Models PG 30 PG 36 C C S S S S U U COMPANY U NITED STATES STOV E A MAJOR CAUSE OF FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES AIR SPACE TO COMBUSTIBLE MATERIALS IT IS OF UT...

Страница 2: ...our Using cooking pellets will increase flavor and efficiency It is important to note that the ash content of the fuel and frequency of operation will determine the frequency of which you will be required to clean your pellet grill A high ash fuel may result in daily cleaning while a low ash content fuel may result in less frequent cleaning Occasionally impurities in the fuel will cause a hard mas...

Страница 3: ...on therefore you should always use some type of hand protection when refueling your grill A power surge protector is required This unit must be plugged into a 110 120V 60 Hz grounded electrical outlet Do not use an adapter plug or sever the grounding plug Do not route the electrical cord underneath in front of or over the grill Do not route the cord in foot traffic areas or pinch the cord under an...

Страница 4: ...rovide floor protection adequate to provide ember protection as shown below Your pellet grill must be installed with 24 609mm clearance to combustibles as shown below Warning Do not operate this grill under a ceiling or overhang FLOOR PROTECTOR 48 SIDE WALL REAR WALL 24 FLOOR PROTECTOR 12 12 12 4 ...

Страница 5: ...in grill body to assembled pedestal with 6 bolts and rivet nuts along bottom of grill body Rivet Nut Assembly Pedestal and Base Assembly Wheel Installation Smoke Stack Installation Parts List Description Qty Pedestal Right Side 1 Pedestal Left Side 1 Pedestal Center 1 Base PG36 1 Base PG30 1 Caster Wheel 2 Fixed Wheel 2 1 4 20 Bolt x 0 75 32 1 4 20 Nut 18 Split Lock Washer 2 1 4 20 Bolt x 1 25 6 S...

Страница 6: ...nt Insure flame plate is level WARNING If flame plate is installed incorrectly the pellets may burn back into the hopper and or the grill may smoke excessively during cook mode and may not maintain set cooking temperature properly Place right drip pan onto grease drain support with flange toward the side of the grill Place left drip pan onto drip pan mounts left drip pan rests on top of right drip...

Страница 7: ... Place your fingers over the burnpot and feel the air movement from the combustion blower Ignitor will glow within 1 minute 7 Press the Power Button to turn the unit off 8 Before replacing the removed components Clean all items with soap and water then rinse and allow to dry Re install components DO NOT TOUCH THE IGNITOR ORTHEAUGER PREPARING TO USE YOUR GRILL Important You must season the grill be...

Страница 8: ... You can easily check the actual temperature compared to the set point temperature by using the Display button on the control board This allows you to determine when the grill has preheated to your desired cooking temperature NOTE During the startup the grill temperature can exceed the set point temperature So it is recommended that you leave the display in Actual to monitor the temperature readin...

Страница 9: ...rill Cook settings If you are in Cook mode and change to Smoke mode the temperature will automatically go to 295 If you are in Smoke mode and change to Cook mode the temperature will automatically go to 300 Temperature control doesn t begin to read and control feed rate for 15 minutes due to the 15 minute start up sequence Make sure to unplug your grill only after it has gone through the shutdown ...

Страница 10: ...specting or cleaning your grill Periodically check the hopper for pellet dust fines build up The accumulation of fines can reduce the efficiency of your grill increase the chance of hopper fires and other unsafe operating conditions If dust fines accumulate sufficiently vacuum out and reload hopper with new pellets ASH REMOVAL Note Let the unit cool to ambient temperature before inspecting or clea...

Страница 11: ...xtended periods of time If operating the grill on the highest heat setting the room temperature could increase enough and lead to potential overheating situations If this happens try operating at a lower heat setting 3 Fuel other than wood pellets is being burned in the stove This pellet grill is designed and tested to use cooking wood pellets Check for signs of fuel other than wood pellets No oth...

Страница 12: ... for about 30 45 minutes Check the thermocouple to see if it s bad Check resistance with volt meter 2 Bad Auger Motor Remove the two retaining screws in the service panel and swing out of the way Remove the auger motor from the auger shaft and try to run the unit If the motor will turn the shaft is jammed on something If the motor will not turn the motor is bad 3 Auger Jam Start by emptying the ho...

Страница 13: ...584 Pedestal Left Side 1 19 26585 Pedestal Center 1 20 80634 Rtd Temperature Probe Grill 1 21 26153 PG36 Drip Pan Right 1 26157 PG30 1 ITEM P N DESCRIPTION QTY 22 892219 PG36 Grate Grilling 1 892218 PG30 1 23 26154 PG36 Drip Pan Left 1 26146 PG30 1 24 892220 Handle Lid 1 25 26158 Backing Plate Homcomfort 1 26 26578 PG36 Exhaust Baffel 1 26630 PG30 27 69927 PG36 Weldment Base 1 69936 PG30 1 28 6983...

Страница 14: ...PARTS DIAGRAM 14 ...

Страница 15: ...AUGER PARTS DIAGRAM 35 38 36 37 39 34 15 ...

Страница 16: ...WIRING DIAGRAM WITH SEARING STATION 16 ...

Страница 17: ...WIRING DIAGRAM WITHOUT SEARING STATION 17 ...

Страница 18: ...ll model number which is on the nameplate attached to the grill When ordering repair parts always give the following information as shown in this list 1 The part number 2 The part description 3 The model number PG 30 PG 36 4 The serial number ____________________ United States Stove Company 227 Industrial Park Road P O Box 151 South Pittsburg TN 37380 800 750 2723 WWW USSTOVE COM HOW TO ORDER REPA...

Страница 19: ...19 ...

Страница 20: ..._______________ ______________________ ______________________ Homcomfort 227 Industrial Park Road South Pittsburg TN 37380 Attn Registration Form PLACE STAMP HERE PLEASE SEAL WITH CLEAR TAPE BEFORE MAILING 20 ...

Отзывы: