TROUBLESHOOTING
AFTER GRILL HAS BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS
Possible Causes:
Possible Remedies: (Unplug stove
fi
rst when possible)
1.
Grill is dirty, which restricts air
fl
ow through the burnpot.
Follow all cleaning procedures in the maintenance section of the
owner’s manual.
2.
Burnpot holes are blocked.
Remove the burnpot and thoroughly clean it.
3.
Blockage in air intake pipe.
Visually inspect the air intake that leads into the burnpot for foreign
material.
4.
Combustion blower is not spinning fast enough.
Clean fan blades and inspect bearings for wear. Ensure the fan is free
of any obstructions.
5. Bad
Pellets.
The brand of pellets or the batch of pellets that are being used may be
of poor quality. If possible, try a different brand of pellets. You might also
want to try a brand that is made from a different type of wood (softwood
vs. hardwood). Different woods have different characteristics when being
burned.
GRILL ENTERS SHUTDOWN MODE UNEXPECTEDLY
Possible Causes:
Possible Remedies: (Unplug stove
fi
rst when possible)
1. The convection blower is overheating and tripping the internal
temperature shutoff.
Clean any dust off of the windings and fan blades. If oiling the blower
does not help, the blower may be bad.
2.
The grill is being left on the highest setting for extended periods of
time.
If operating the grill on the highest heat setting, the room temperature
could increase enough and lead to potential overheating situations. If this
happens, try operating at a lower heat setting.
3.
Fuel other than wood pellets is being burned in the stove.
This pellet grill is designed and tested to use cooking wood pellets.
Check for signs of fuel other than wood pellets. No other types of fuel
have been approved for this pellet grill. If there are signs of other types
of fuel being used, stop using them immediately.
4.
Power surge or brown out situation.
A power surge, spike, or voltage drop could cause the thermocouple
to malfunction. Use a surge protector
5.
Thermocouple is malfunctioning.
If the other items check out OK, replace the thermocouple.
Error Codes
Possible Causes:
Possible Remedies: (Unplug stove
fi
rst when possible)
1.
Error Code 1 - Over Temperature - The measured temperature has
exceeded the overtemp set point.
Call Customer service (800) 750-2723.
2.
Error Code 2 - No Start - The grill did not reach the warm condition
set point before the timer expired (15 Min.)
Visually inspect the ignition system. Try to start the grill again. If the
grill fails to start a second time call customer service (800) 750-2723.
3.
Error Code 3 - Power Failure - The power failed while the grill was
operating and the grill temperature was below the warm set point
when power was returned.
Press the power and the prime button at the same time to resume
standard operation.