6
Step 5
Connect Hose & Regulator to Cylinder Specifications
Lower the cylinder cover onto cylinder base.
• You must provide propane gas and propane
cylinder. Use a standard 20 lb. propane cylinder
only.
•
Use this heater only with a propane vapor withdrawal
supply system. See Chapter 5 of the Standard for
Storage and Handling of Liquified Petroleum Gas,
ANSI/NFPA 58. Your local library or fire department
should have this book.
•
The minimum permissible gas supply pressure of 10
Standard 20 lb. tank W.C. is required for purpose of
input adjustment.
• The minimum hourly of 1700 Btu is required input
rating for a heater for automatic operation at ratings
less than full input rating. The pressure regulator and
hose assembly supplied with the appliance must be
used.
•
The installation must conform with local codes, or in
the absence of local codes, with National Fuel Gas
Code, ANSI Z223.1.
• A dented, rusted or damaged propane cylinder
may be hazardous and should be checked by your
cylinder supplier. Never use a propane cylinder with
a damaged valve connection.
•
The propane cylinder must be constructed and
marked in accordance with the specifications
for LP gas cylinders of the U.S. Department of
Transportation (DOT).
• Never connect an unregulated propane cylinder to
the heater.
• Attach regulator to cylinder.
• Tighten securely.
• Complete attachment.
• Install cylinder.
•
Make 2-3 oz. of leak check solution (one part liquid
dish-washing detergent and three parts water).
•
Apply several drops of solution where hose connects
to Burner Assembly.
•
Apply several drops of solution where hose attaches
to regulator.
•
Apply several drops of solution where regulator
connects to Cylinder.
• Make sure all Patio Heater & Light valves are OFF.
•
Turn Cylinder Valve ON. If bubbles appear at any
connection, there is a leak.
• Turn Cylinder Valve OFF.
• If leak is at Hose/Regulator connection: tighten
connection and perform another leak test.
• If leak is at Regulator/Cylinder Valve connection:
disconnect, reconnect, and perform another leak
check. If you continue to see bubbles after several
attempts, cylinder valve is defective and should
be returned to cylinder’s place of purchase. If NO
bubbles appear at any connection, the connections
are secure.
• Turn Cylinder Valve OFF. NOTE: Whenever gas
connections are loosened or removed, you must
perform a complete leak test.
• Complete installation.
Assembly/Leak Check
WARNING:
• Perform all leak tests outdoors.
•
Extinguish all open flames.
•
NEVER leak test when smoking.
• Do not use the heater until all connections have
been leak tested and do not leak.