Homa TP 22 Скачать руководство пользователя страница 23

EngliSH | 23

1.6. Technical terms

Various technical terms are used in this operating and 
maintenance manual.

Dry run

The product is running at full speed, however, there is no 
liquid to be pumped. A dry run is to be strictly avoided. If 
necessary, a safety device must be installed.

“wet” installation type

This installation type requires the product to be immersed 
in the pumped fluid. It is completely surrounded by the 
pumped fluid. Please observe the values for the maximum 
submersion depth and the minimum water coverage.

“dry” installation type

In this installation type, the product is installed dry, i.e. the 
pumped fluid is delivered to and discharged via a pipeline 
system. The product is not immersed in the pumped fluid. 
Please note that the surfaces of the product become very 
hot!

“transportable” installation type

With this installation type the product is equipped with a 
pedestal. It can be installed and operated at any location. 
Please observe the values for the maximum submersion 
depth and the minimum water coverage, and remember 
that the surfaces of the product become very hot.

“S1” operating mode (continuous operation)

At the rated load, a constant temperature is reached that 
does not increase even in prolonged operation. The oper-
ating equipment can operate uninterruptedly at the rated 
load without exceeding the maximum permissible tem-
perature.

“S2” operating mode (short-term operation)

The operating time is specified in minutes, for example, 
S2-20. That means, that the machine can work 20 min-
utes and should pauses after it, as long as the machine is 
cooled down to 2K over medium temperature.

Operating mode „S3“ (intermittent operation): 

For these operating modes, after the abbreviation, the 
duty cycle is displayed as well as the cycle duration if it 
deviates from 10 minutes. Example S3 30% means, that 
the machine can work 3 minutes and afterwards should 
pauses 7 minutes.

“Sip operation”

Siphoning operation is similar to dry running. The product 
operates at full speed, but only small amounts of liquid 
are pumped. 
Sip operation is only possible with certain types; see the 
“Product description” chapter.

Dry-run protection

The dry-run protection is designed to automatically shut 
down the product if the water level falls below the mini-
mum water coverage value of the product. This is made 
possible by installing a float switch.

Level control 

The level control is designed to switch the product on or 
off depending on the filling level. This is made possible by 
installing a float switch.

2. Safety

This chapter lists all the generally applicable safety instruc-
tions and technical information. Furthermore, every other 
chapter contains specific safety instructions and techni-
cal information. All instructions and information must be 
observed and followed during the various phases of the 
product‘s lifecycle (installation, operation, maintenance, 
transport etc.). The operator is responsible for ensuring 
that personnel follow these instructions and guidelines.

2.1. Instructions and safety information

This manual uses instructions and safety information for 
preventing injury and damage to property.
To make this clear for the personnel, the instructions and 
safety information are distinguished as follows:

Each safety instruction begins with one of the following 
signal words:

Danger: 

Serious or fatal injuries can occur!

Warning:

 Serious injuries can occur!

Caution:

 Injuries can occur!

Caution (Instruction without symbol):

 Serious damage 

to property can occur, including irreparable damage!

Safety instructions begin with a signal word and descrip-
tion of the hazard, followed by the hazard source and 
potential consequences, and end with information on  
preventing it.

2.2. Guidelines used and CE certification

Our products are subject to
• 

various EC directives

• 

various harmonized standards

• 

various national standards.

Please consult the EU Declaration of Conformity for the 
precise information and the guidelines and norms in ef-
fect. The EU Declaration of Conformity is issued in ac-
cordance with EU Directive 2006/42/EEC, Appendix II A. 
Also, various national standards are also used as a basis 
for using, assembling and dismantling the product. These 
include the German accident prevention regulations, VDE 
regulations, German Equipment Safety Law etc. The CE 
symbol is found either on the type plate or next to the 
type plate. The type plate is attached to the motor casing.

2.3. General safety

• 

Never work alone when installing or removing the 
product.

• 

The machine must always be switched off before 
any work is performed on it (assembly, dismantling, 
maintenance, installation). The machine must be dis-
connected from the electrical system and secured 
against being switched on again. All rotating parts 
must be at a standstill.

• 

The operator should inform his/her superior immedi-
ately should any defects or irregularities occur.

• 

It is of vital importance that the system is shut down 
immediately by the operator if any problems arise 
which may endanger safety of personnel. Problems 
of this kind include: 

Содержание TP 22

Страница 1: ...Original Betriebsanleitung EN Original Instruction Manual NL Originele handleiding TP22 TP26 TP35...

Страница 2: ...Beschreibung 09 3 1 Verwendung 09 3 2 Einsatzarten 09 3 3 Aufbau 09 4 Verpackung Transport und Lagerung 11 4 1 Anlieferung 11 4 2 Transport 11 4 3 Lagerung 11 4 4 R cklieferung 11 5 Aufstellung und I...

Страница 3: ...um Unfall schutz und zur Unfallverh tung Diese Betriebsanleitung muss dem Bedienpersonal jederzeit am Einsatzort des Produktes verf gbar sein 1 3 Bestimmungsgem e Verwendung Die HOMA Produkte entsprec...

Страница 4: ...5 2 Ersatzteile An und Umbauten Es d rfen nur Originalersatzteile des Herstellers f r Reparatur Austausch sowie An und Umbauten verwen det werden Nur diese garantieren h chste Lebensdauer und Sicherh...

Страница 5: ...n 03 72 92 50 00 02 21 90 148 81 0 74 04 91 07 67 Glaubrecht Pumpenservice GmbH Eugen Boss GmbH Co KG B hler Antriebstechnik Bornitzstr 13 Tankweg 27 Wei erlenstr 1G 10367 Berlin 44147 Dortmund 79108...

Страница 6: ...Schl rfbetrieb kommt einem Trockenlauf gleich Die Pumpe l uft mit voller Drehzahl es werden aber nur sehr geringe Mengen an Medium gef rdert Der Schl rfbetrieb ist nur mit einigen Typen m glich siehe...

Страница 7: ...d Ma nahmen zu ergreifen damit sich keine Personen unter h ngenden Lasten aufhalten k nnen Weiterhin ist es untersagt h ngende Lasten ber Arbeitspl tze zu bewegen an denen sich Personen aufhalten Beim...

Страница 8: ...Atmosph re geeignet F r diesen Einsatz m ssen die Pumpen bestimmte Richtlinien erf llen Ebenso m ssen bestimmte Verhaltensregeln und Richtlinien vom Betreiber eingehalten werden Pump en welche f r den...

Страница 9: ...et z B f r die industrielle Brauch wasserversorgung 3 3 Aufbau Das voll berflutbare Aggregat besteht aus dem Motor dem Pumpengeh use und dem passendem Laufrad Alle wichtigen Bauteile sind gro z gig di...

Страница 10: ...bei korrekter Drehrichtung leicht entgegen dem Uhrzeiger sinn an Die korrekte Drehrichtung der Pumpe ist gegeben wenn die Pumpe sich gegen den Uhrzeigersinn bewegt da der Motor von oben gesehen im Uh...

Страница 11: ...bkni cken Besch digungen und Feuchtigkeitseintritt zu sch tzen Gefahr durch elektrischen Strom Durch besch digte Stromzuf hrungsleitungen droht Lebensgefahr Defekte Leitungen m ssen sofort vom qualifi...

Страница 12: ...rstandsdifferenz zwischen Ein und Ausschaltpunkt l sst sich individuell bestimmen F r eine einwandfreie Funktion beachten Sie bitte die nachstehenden Hinweise Die Befestigungspunkte sowie die L nge de...

Страница 13: ...ng nicht notwendig da diese immer mit der korrekten Drehrich tung laufen Bei 3Ph Motoren muss vor der Inbetriebnahme die Drehrichtung berpr ft werden Bei Verwendung eines HOMA Schaltger tes mit Drehri...

Страница 14: ...ssen die n tigen K rperschutzmittel getragen werden Die Maschine muss f r s mtliche Arbeiten vom Stromnetz getrennt werden Ein unbeabsichtig tes Einschalten muss verhindert werden Weiterhin sind bei A...

Страница 15: ...mit dem Hersteller Optische Kontrolle des Betriebsmittels lstand Die genaue F llmenge entnehmen sie bitte der Ersatztei leliste oder erfragen diese beim Hersteller lzustand Der Zustand der Gleitringd...

Страница 16: ...gelm ig halbj hrlich von Hand zu drehen Dies verhindert Eindr ckmarken in den Lagern und ein festsetzen des L ufers 7 3 Wiederinbetriebnahme nach l ngerer Einlagerung Die Maschine muss vor Wiederinbet...

Страница 17: ...schen Pumpe saugt sich am flexiblem Boden fest Stellen sie die Pumpe auf einen festen Untergrund Maschine l uft die angegebenen Betriebswerte werden nicht eingehalten Ursache Abhilfe Zulauf verstopft...

Страница 18: ...seinrichtungen sind dann mit dem Lastkabel ausgef hrt Aderbezeichnung Motor berwachungseinrichtung berwachungen in der Wicklung T1 T2 Temperaturbegrenzer 2 Schalter in Reihe T1 T4 Temperaturregler 2 S...

Страница 19: ...DEUTSCH 19 Notizen Notes...

Страница 20: ...1 Use 26 3 2 Type of application 26 3 3 Structure 26 4 Package Transport Storage 28 4 1 Delivery 28 4 2 Transport 28 4 3 Storage 28 4 4 Returning to the supplier 28 5 Installation and commissioning 29...

Страница 21: ...ble to personnel at all times and also be made available where the product is used 1 3 Proper use The HOMA products comply with the valid safety regu lations and meet the demands of state of the art t...

Страница 22: ...ufactur er may be used for repairs replacements add ons and conversions Only these parts guarantee a long working life and the highest level of safety These parts have been specially designed for our...

Страница 23: ...uct on or off depending on the filling level This is made possible by installing a float switch 2 Safety This chapter lists all the generally applicable safety instruc tions and technical information...

Страница 24: ...connec tion data sheet must be observed when connecting the product The technical specifications must be strictly adhered to If the machine has been switched off by a protective device it must not be...

Страница 25: ...s e g suspension unit and pipeline operating site immersion depth etc Once the product has been in stalled we recommend that the operator make additional measurements under all operating conditions Ca...

Страница 26: ...industrial service water supply 3 3 Structure The submersible aggregate consists of the motor the pump casing and the suitable impeller All important parts are of generous dimension No Description 1...

Страница 27: ...htly onto the edge and switch on for a short time When seen from above the pump rebounds slightly anticlockwise in correct direction of rotation The direction of rotation is correct if the pump moves...

Страница 28: ...packaging must protect the product against damage Please contact the manufacturer before returning 4 Package Transport Storage 4 1 Delivery On arrival the delivered items must be inspected for da mage...

Страница 29: ...ching point and tripping point can be deter mined individually Please note the following information for perfect function The mountings as well as the length of the freely moveable end of the float ca...

Страница 30: ...ction of rotation The check can be carried out by observation of the start jerk For this place the pump vertically onto the floor slightly onto the edge and switch on for a short time When seen from a...

Страница 31: ...d Furthermore the respective protective measures according to the Employers Liability Association regulations BGV the Statutory Accident insurance GUV must be complied with when working in basins and...

Страница 32: ...e consult the manufacturer Visual check of the operating material Oil Level Please take the precise filling quantity from the spare parts list or make a request to the manufacturer Oil Condition The c...

Страница 33: ...the elastomers of the seals During lengthy periods of storage regularly for ex ample every six months turn the impeller or propeller by hand This prevents indentations in the bearings and stops the ro...

Страница 34: ...exible ground Move the pump on hard ground The machinery is running the indicated operating values are not met Cause Remedy Inlet obstructed Clean inlet gate valve suction piece suction branch suction...

Страница 35: ...ng devices are run from the power cable Cable identification Motor Monitoring system Monitoring in winding T1 T2 Temperature limiter 2 switches in series T1 T4 Temperature controller 2 switches in ser...

Страница 36: ...wijzen 42 3 3 Opbouw 42 4 Verpakking transport en opslag 44 4 1 Aanlevering 44 4 2 Transport 44 4 3 Opslag 44 4 4 Retourneren 45 5 Opstelling en inbedrijfstelling 45 5 1 Algemeen 45 5 2 Installatie 45...

Страница 37: ...ventie en of breidt deze uit Deze handleiding moet altijd beschikbaar zijn voor het bedie ningspersoneel op de werkplek van het product 1 3 Beoogd gebruik De HOMA producten voldoen aan de geldende vei...

Страница 38: ...afspraken lopen ten minste tot aan het overeengekomen einde van de wettelijke garan tietermijn van het product 1 5 2 Onderdelen aan en ombouwwerkzaamheden Er mogen uitsluitend originele onderdelen va...

Страница 39: ...ng wordt een gelijkblijvende temperatuur bereikt die ook bij langer bedrijf niet meer stijgt Het materieel kan ononderbroken onder nominale belasting werken zonder dat de toegestane temperatuur wordt...

Страница 40: ...onmiddellijke stilzetting door de bediener is dwin gend noodzakelijk wanneer er gebreken optreden die de veiligheid in gevaar brengen Hieronder vallen Falen van de veiligheids en of bewakingscontro l...

Страница 41: ...el is verantwoordelijk voor de nale ving van de voorschriften Tijdens het bedrijf draaien be paalde onderdelen waaier propeller om de vloeistof te verpompen Door bepaalde bestanddelen kunnen er aan de...

Страница 42: ...fen Het verpompen van explosieve vloeistoffen bijv benzine kerosine etc is ten strengste verboden De producten zijn niet ontworpen voor deze vloeistoffen 3 Algemene beschrijving 3 1 Toepassing Pompen...

Страница 43: ...Algemene motorgegevens Toegestane mediumtemperatuur 40 C Isolatieklasse B 130 C Beschermingsklasse IP68 Standaard kabellengte 10 m Asafdichting glijringafdichting Carbon keramiek motorzijde Siliciumc...

Страница 44: ...den gelet dat de anticorrosiecoating niet beschadigd raakt De machine mag niet worden opgeslagen in ruim tes waarin laswerkzaamheden plaatsvinden om dat de daarbij optredende gassen en stralingen de e...

Страница 45: ...ij toepassing in vloeistoffen met gezondheids risico is gedecontamineerd De verpakking moet het product beschermen tegen beschadigingen Raadpleeg de fabrikant voorafgaand aan het retourneren 5 Opstell...

Страница 46: ...chnische en mechanische instellingen mogen alleen door vakkrachten worden uitgevoerd Deze machine is alleen geschikt voor toepassing bij de aangegeven bedrijfsvoorwaarden 5 4 Voorbereidende werkzaamhe...

Страница 47: ...j extra beveiligingssystemen in te bouwen bijv overspan nings onderspannings of faseuitvalrelais bliksembevei liging etc Bij het aansluiten van de machine moeten de plaatselijke en wettelijke voorschr...

Страница 48: ...lle materialen en gereedschappen op de daarvoor bestemde plaats Vloeistoffen voor het bedrijf bijv olie smeermidde len etc moeten in geschikte reservoirs worden op gevangen en volgens de voorschriften...

Страница 49: ...an De uitlopende bedrijfsvloeistof kan brandwonden veroorzaken Laat de machine daar om eerst afkoelen tot omgevingstemperatuur Bevei lig de machine tegen omvallen en of wegglijden 7 Buitenbedrijfstell...

Страница 50: ...van het stroomnet te scheiden Neem de juiste voorzorgsmaatregelen Waarborg op elk moment dat de veiligheidsuitscha keling van de machine door een tweede persoon kan worden bediend Borg beweegbare mac...

Страница 51: ...ich aan flexibele bodem vast Plaats de pomp op een stevige vlakke ondergrond Machine draait maar de opgegeven bedrijfswaarden worden niet aangehouden Oorzaak Oplossing Toevoer verstopt Toevoerleiding...

Страница 52: ...n dan met de hijskabel uitgevoerd Aderaanduiding motor Bewakingscontrole Bewakingen in de wikkeling T1 T2 Temperatuurbegrenzer 2 schakelaars in serie T1 T4 Temperatuurregelaar 2 schakelaars in serie T...

Страница 53: ...10 Installationsbeispiel 10 Installation 10 Installatievoorbeeld 625 330 1000 45 D A C B 225 Rohr Pipe leiding 2 ISO Rohr Pipe leiding ISO EIN ON AAN AUS OFF UIT EIN ON AAN AUS OFF UIT Alarm alarm Ala...

Страница 54: ...54 11 Bauma e 11 Dimensions 11 Afmetingen 120 G 2 120 276 G 2 235 513 145 460 78 143 166 96 AUS OFF UIT EIN ON AAN TP 22 TP 26...

Страница 55: ...55 115 G 2 115 237 G 2 154 479 111 426 35 99 123 96 AUS OFF UIT EIN ON AAN TP 35...

Страница 56: ...dingte Kontaminierung des Ger tes toxisch nein ja welche Stoffe tzend nein ja welche Stoffe mikrobiologisch nein ja welche Stoffe explosiv nein ja welche Stoffe radioaktiv nein ja welche Stoffe sonsti...

Страница 57: ...the instruments toxic no yes substance corrosive no yes substance microbiological no yes substance explosive no yes substance radioactive no yes substance other substances no yes substance Legally bin...

Страница 58: ...tourneren Contaminatie van het apparaat als gevolg van de toepassing giftig nee ja welke stoffen bijtend nee ja welke stoffen microbiologisch nee ja welke stoffen explosief nee ja welke stoffen radioa...

Страница 59: ...our other household waste You are liable to dispose of all your electronic or electrical waste equipment by relocating over to the specified collection point for recycling of such hazardous waste Isol...

Страница 60: ...x 49 0 2247 702 44 e Mail info homa pumpen de Internet www homa pumpen de Industriestra e 1 53819 Neunkirchen Seelscheid Telefon 49 0 2247 702 0 Fax 49 0 2247 702 44 e Mail info homa pumpen de Interne...