9. Maintenance and Repair

Before maintenance or repair disconnect the pump

from the power supply to avoid accidental starting of the
pump!

Before carrying out maintenance and service, the pump

must be thoroughly flushed with clean water. Rinse the
pump parts in clean water after dismanteling.

In case of a defect of the pump, a repair shall be car-

ried out only by the manufacturer or through an authorized
workshop. Conversions or alternations of the machine/unit
are permittes only after arrangement with the manufacturer.
Only HOMA spare parts shall be used.

In accordance with the product liability law we point out

that we shall not be liable for damages caused by our pro-
duct due to unauthorized repair by persons other than the
manufacturer or an authorized workshop or due to the use
of spare parts other than original HOMA parts. The same
product liability limitations are valid for accessories.

When unscrewing the inspection screw of the oil cham-

ber, please note that pressure may have built up in the
chamber. Do not remove the screw until the pressure has
been fully relieved.

Before maintenance or repair make sure that all rota-

ting parts stand still!

Pumps running under normal operation conditions should
be inspected at least once a year. If the pumped liquid is
very muddy or sandy or if the pump is operating conti-
nuously, the pump should be inspected every 1.000 opera-
ting hours.

When the pump is new or after replacement of the shaft
seals, check the oil level after one week of operation.

For long and trouble-free operation of the pump, following
points should be checked regularly:

- Nominal current (A): Check with amp-meter.

- Pump parts: Check for possible wear. Replace defective
parts.

- Ball bearings: Check the shaft for noisy or heavy operation
(turn the shaft by hand). Replace defective ball bearings. A
general overhaul of the pump is usally required in case of
defective ball bearings or poor motor function. This work
must be carried out by an authorized service
workshop.

- Cable entry: Make sure that the cable entry is watertight
and that the cables are not bent sharply and/or pinched.

- Oil level and oil condition in oil chamber: The oil becomes
greyish white like milk if it contains water. This may be the
result of defective shaft seal. The oil should be replaced
after 3000 operating hour. Oil type: Shell Tellus
C22, degradable HOMA-Atox available on request..

- Mechanical seals: Check the mechanical seals for wear-
out.

10. Fault Finding Chart

Before maintenance or repair disconnect the pump

from the power supply to avoid accidental starting of the
pump!

Fault

Cause

Remedy

Motor does not start.
Fuses blow or motor
starter trips out imme-
diately. 

Caution:

 Do not

start again!

 Supply failure; short-

circuit; earth-leakage;
fault in cable or motor
winding

 Have the cable and

motor checked and
repaired by a quali-
fied electrician

 Fuses blow due to use

of wrong type of fuse

 Install fuses of the

correct type

 Impeller blocked by

impurities

 Clean the impeller

 Level switch out of

adjustment or defecti-
ve

 Check the level

switch

Pump operates, but
motor starter trips out
after a short while

 Low setting of thermal

relay in motor starter

 Set the relay in ac-

cordance with the
specifications on the
pump label

 Increased current con-

sumption due to large
voltage drop

 Measure the voltage

between two motor
phases. Tolerance:
± 10% (± 5% for ex-
plosion-proof
pumps)

 Impeller blocked by

impurities. Increased
current consumption in
all three phases

 Clean the impeller

Pump operates at be-
low-standard

 Impeller blocked by

impurities

 Clean the impeller

performance and power
consumption

 Wrong direction of

rotation (only 3 Ph-
pumps)

 Check the direction

of rotation and pos-
sibly interchange
two phases (see
section 6.4)

Pump operates, but
gives no liquid

 Discharge valve clo-

sed or blocked

 Check the discharge

valve and possibly
open and/or clean

 Non-return valve blok-

ked

 Clean non-return

valve

 Air in pump

 Vent the pump

Содержание AMX 644-330 53 F Series

Страница 1: ...ntage und Bedienungsanleitung Installation and Operation Instruction Manual Montage en Bedrijfinstrukties Manuel d instructions de montage et d exploitation Baureihe Series Serie S ries AMX 644 330 53...

Страница 2: ...Seite 35 Page 35 Pagina 36 Page 36 DEUTSCH ENGLISH NEDERLANDS FRAN AIS Elektroanschluss Electrical connection Aansluitdiagram Sch ma de raccordement Bauma e Dimensions Bouwmaten Dimensions Ersatzteill...

Страница 3: ...die HOMA Pumpenfabrik GmbH Industriestrasse 1 D 53819 Neunkirchen Seelscheid erkl ren hiermit da die Pumpentypen MX 34 K 33 K 44 K 55 K 66 aufgrund Ihrer Konzipierung und Bauart sowie in der von uns i...

Страница 4: ...r nach dem Produkthaf tungsgesetz f r Sch den die durch unser Ger t verursacht werden wenn die Hinweise und Vorschriften aus dieser Bedienungsanleitung nicht eingehalten werden nicht haf ten F r Zubeh...

Страница 5: ...abe direkt DOL gestartet werden sollen m ssen bei einer Netzspannung von 400 V 3Ph die Wicklungsenden im Dreieck geschaltet werden s Abb 4 6 2 Temperaturf hler Alle Pumpen der Baureihe A sind mit eine...

Страница 6: ...lansch montiert ist so dass ein Herausfallen beim Herablas sen der Pumpe ausgeschlossen ist Kette am Pumpen Traggriff bzw Trag sen befestigen Pumpe mit den F hrungsklauen des Kupplungsgegen flansches...

Страница 7: ...hlei pr fen ggf austauschen Wellenlager durch Drehen der Welle auf freien und ge r uschlosen Lauf pr fen Bei Sch den ist eine Gene ral berholung durch eine HOMA Fachwerkstatt bzw den Werkskundendienst...

Страница 8: ...8 ELMOS Karl Henne GmbH Schmidener Stra e 29 70372 Stuttgart 07 11 56 00 07 PAW Pumpen Aggregate GbR Kleine Basch tzer Str 3 02625 Bautzen 0 35 91 20 00 10 Giese Pumpentechnik Belsemer Steg 14 72131 O...

Страница 9: ...Machi nery Directive 89 392 EEC Appendix IIA We HOMA Pumpenfabrik GmbH Industriestrasse 1 D 53819 Neunkirchen Seelscheid hereby declare that in respect to their design and construction the following...

Страница 10: ...accesso ries 3 Applications and Technical Description 3 1 Applications If the pump is used for cleaning or maintenance of swimming pools make sure that no persons stay in the swimming pool during ope...

Страница 11: ...s The contact of these sensors opens in case of overtemperature and switches off the motor power supply Standard models have the sensors connected to the motor power supply cable the wire ends marked...

Страница 12: ...not da maged during the pump operation Make sure that the cables are not sharply bent or pinched 7 3 Dry Installation For installation of the pump outside the collection sump a suction pipe must be c...

Страница 13: ...ly required in case of defective ball bearings or poor motor function This work must be carried out by an authorized service workshop Cable entry Make sure that the cable entry is watertight and that...

Страница 14: ...ct is defeated by a streng technical end control before delivery If the unit still gives an occasion for a legitimated com plain you have the claim of an appropriated correction free of charge Warrant...

Страница 15: ...MA Pumpenfabrik GmbH Industriestrasse 1 D 53819 Neunkirchen Seelscheid verklaren hiermee dat de pomp typen MX 34 K 33 K 44 K 55 K 66 Op grond van hun concipi ring en bouwwijze als ook in de door ons i...

Страница 16: ...schade welke door onze machines veroorzaakt worden wanneer de aanwijzin gen en voorschriften uit deze gebruiksaanwijzing niet in acht genomen worden Voor toebehoren gelden dezelfde regels 3 Inzetbaar...

Страница 17: ...emde besturingskast zie afb 2 en 3 Wanneer een voor ster driehoek voorbereidde motor met 400 V 3fase spanningsopgave direkt DOL gestart moet worden moet er bij een netspanning van 400 V 3fase de wikke...

Страница 18: ...uitsparing van de tegenkoppeling gemonteerd is zodat het uitvallen van de dichting bij het uithalen van de pomp uitgesloten is Ketting aan de handgreep of draagogen bevestigen Pomp met de geleideklauw...

Страница 19: ...eren Pomphuis en waaier op zichtbare slijtage testen ggf austauschen As Lager door het met de hand draaien van de as deze op vrije en geruislozeloop testen Bij schade is een com plete revisie door een...

Страница 20: ...oduct ondergaat voor uitlevering een strenge technische eindcontrole Mocht het apparaat desondanks reden tot een gerechtvaardige garantieclaim geven dan heeft u recht op een aansprekende kostenloze af...

Страница 21: ...36 1 D claration de conformit D claration de conformit selon la directive machine CE 89 392 CEE annexe II A Nous soussign s HOMA Pumpenfabrik GmbH Industrie strasse 1 D 53819 Neunkirchen Seelscheid ce...

Страница 22: ...t consignes de la pr sente notice Ces consignes s appliquent aussi aux accessoires 3 Utilisation et caract ristiques techniques 3 1 Utilisation Si les pompes sont utilis es pour le nettoyage entretien...

Страница 23: ...1 W2 Pour un d marrage Etoile Triangle la pompe sera branch e un d marreur appro pri voir fig 2 et 3 Si un moteur quip comme d crit ci dessus pour un d marrage Etoile Triangle doit d marrer en direct...

Страница 24: ...t Les barres de guidage doivent tre totalement exemptes de jeu afin d viter toute nuisance sonore pendant le fonctionnement de la pompe D barrasser le puits de toutes mati res solides d bris cailloux...

Страница 25: ...n de la pompe n cessite l accord pr alable du constructeur Seules les pi ces de rechange d origine doi vent tre utilis es Il est rappel que conform ment la l gislation en ma ti re de responsabilit du...

Страница 26: ...ccompagn de la preuve d achat La garantie comprend la r paration des pi ces reconnues d fectueuses Les frais de d montage et de montage du mat riel d fectueux sur le lieu d utilisation les frais de d...

Страница 27: ...or Star Delta Start prepared D marrage toile triangle Normalausf hrung Standard model Version standard T1 T3 Temperaturf hler ca 130 C Temperature sensors approx 130 C Sonde thermique 130 C S1 Dichtun...

Страница 28: ...lich Dreieckschaltung der Wick lung Starter connection Direct on line Start for Star Delta Start prepared motors Delta connection of stator win dings D marrage Direct DOL pour un moteur toile triangle...

Страница 29: ...ng base stand Natte opstelling met bodemring Installation mobile sur socle Station re Trockenaufstellung vertikal Permanent dry well installation vertical Droge opstelling vertikaal Station re Trocken...

Страница 30: ...120 160 18 902 1012 310 370 60 18 M16 25 M16 25 120 120 80 18 24 2 162 342 150 150 200 200 MX3468 F bis MX3474 F 138 1341 350 450 90 140 20 1125 1225 360 420 60 20 M16 25 M16 25 100 110 80 15 20 2 125...

Страница 31: ...0 120 120 80 18 27 2 166 440 250 250 250 300 300 K5574 bis K5576 G EX 170 1433 490 600 125 180 23 1166 1286 410 470 60 23 M20 80 M20 80 120 120 80 18 24 2 162 420 250 250 250 250 300 K5574 bis K5576 G...

Страница 32: ...r Bezeichnung Menge Lieferanschrift Unterschrift Firmenstempel 15 Order Sheet for Spare Parts To HOMA Pumpenfabrik GmbH D 53819 Neunkirchen Seelscheid Fax 49 22 47 7 02 44 Pump type see pump label Yea...

Страница 33: ...al Afleveradres handtekening firmastempel 15 Commande de pi ces d tach es HOMA Pumpenfabrik GmbH D 53819 Neunkirchen Seelscheid Fax 49 22 47 7 02 44 Type de pompe Voir plaque pompe Ann e de constructi...

Страница 34: ...ung 999 xx Ersatzteile f r Schaltge r t 722 Anschlussstutzen 16 Spare part list and drawings 16 1 Spare part list ATTENTION The following list contains parts that do not correspond to every pump type...

Страница 35: ...koppeling 999 xx Onderdelen voor scha kelkast 722 Aansluiting 16 Liste de pi ces d tach es et plans 16 1 Liste de pi ces d tach es ATTENTION La liste ci dessous contient des pi ces qui ne sont pas pr...

Страница 36: ...36 16 2 Ersatzteilzeichnung Spare part drawings Liste de pi ces d tach es M23 MX24 P M23 MX24 PU M23 MX24 P Ex M23 MX24 PU Ex...

Страница 37: ...0 01 932 01 550 412 05 412 03 914 04 433 02 932 01 433 01 412 03 932 01 914 02 163 839 05 839 10 930 914 12 900 561 970 834 02 834 03 914 05 812 914 10 412 06 914 05 903 02 411 01 822 02 950 151 412 0...

Страница 38: ...10 914 12 834 01 834 02 914 07 932 02 950 914 07 940 552 914 01 101 230 502 900 839 05 970 561 930 839 10 914 12 834 01 834 02 914 07 903 02 411 01 950 824 01 826 01 824 02 826 02 812 914 11 914 10 83...

Страница 39: ...04 412 02 412 05 914 04 433 02 550 02 932 01 433 01 932 01 914 03 412 02 412 01 940 552 914 01 230 502 101 914 04 433 02 550 02 932 01 433 01 932 01 914 02 412 02 412 01 151 411 01 903 02 412 04 412 0...

Страница 40: ...40...

Отзывы: