Set up before commissioning
TKS Serie | Version 1.04
11
- There must be a suction device with min. 690 m3 /
h extraction capacity, min. 20 m / s flow velocity at
the suction connection; Hose diameter 100 mm,
max. Length 4 m.
- Before commissioning, the machine must be con
-
nected to an extraction system with a flexible,
flame-resistant suction line. The extraction must be
switched on automatically when switching on the
table saws. When the machine is switched on, the
extraction system starts automatically after a 2-3
second start-up delay. An overload of home secu
-
rity is prevented.
9.2 Montage der Circular Table Saw
Use the following steps to make the machine operatio
-
nal.
Assembly of the substructure
Step 1: Assemble the upper case to the lower case as
shown in Figure 6.
Fig. 6: Mounting the machine housing
Mount side workbench
Step 1: Loosely screw on the extension table on the side
of the saw, align and center it, then tighten the
screws underneath and to the side of the table.
Check the centering at the corners and the flat
alignment of the surface on the main table with
the aid of wooden blocks and spirit level, then
tighten all screws of the worktable.
Fig. 7: Mount workbench
CAUTION!
Risk of injury due to a machine that is not stably er
-
ected!
Check the stability of the machine after placing it on
stable ground.
DANGER!
Some metal parts can be sharp-edged. Check all me
-
tal parts to avoid injury.
CAUTION!
Pay attention to the weight of the machine!
The machine may only be set up by two persons.
Check the aid accordingly for sufficient dimensioning
and load capacity.
ATTENTION!
To ensure sufficient stability of the machine, it should
be screwed to the ground. There are 4 holes on the
machine housing for this purpose.
VORSICHT!
The workbench is heavy. For your safety, ensure that
you have sufficient aids and support.