MAINTENANCES AND SERVICING
HOLZMANN Maschinen Austria
www.holzmann-maschinen.at
Seite 26
Rangierwagenheber / Service jack RWH125ALU - RWH180ALU - RWH250ALU
Fig. 1
11.3
Change the hydraulic oil at least once every three years:
1. With the Jack fully lowered, remove the Oil Filler Plug on the side of the Housing.
2. Tip the Jack to allow the old hydraulic oil to drain out of the Housing completely, and dispose of the old hy-
draulic oil in accordance with local regulations.
3. With the Jack upright, completely fill the Housing with a high quality hydraulic oil (not included) until the oil is
1/4
″
below the fill hole.
4. Open the valve by turning the Handle counterclockwise and pump the Handle to bleed air from the system.
5. Recheck oil level and re-fill as needed.
6. Reinstall the Oil Filler Plug.
11.4
Wipe dry with a clean cloth. Then, store the Jack in a safe, dry location out of reach of children and
other non-authorized people.