Holtkamp Electronics SUNCASH engl. techn. Stand 04.2016 4047_04.2016 V09.2019
- 18 -
Max. change:
50.0 EUR
The setting Maximum change offers you the possibility, to set the
maximum amount which can be changed at one time. With the
RESET
and
PLUS
button the number values can be altered in
steps of 0.1 from 0.0 to 9999.9. With
OK
button you switch to the
next menu item.
Note: If the maximum altered value is set to more than 20
coins, the coin hopper can run out and therefore not pay out
the full sum.
Card pawn:
5.0 EUR
The card pawn offers you the possibility, to set the price for the
purchase of a card. The card deposit can be set in steps of 0.1
from 0.0 to 999.9. With the setting 0.0 the card sales is deacti-
vated.
By the card pawn setting you must pay attention, that
the pawn setting, divided by the smallest set channel
value of the coin tester/bank note reader reaches a
whole number, as overpaying is not possible.
With the
RESET
and
PLUS
button you can change the values,
with the
OK
button you switch to the next menu item.
Initial amount:
0.0 EUR
The initial amount offers you the possibility to set the amount in
a card initialisation operation, which will be re-valued to a type
11 chip card. The initialisation amount can be set in steps of 0.1
from 0.0 to 999.9. With the
RESET
and
PLUS
button you can
change the values, with the
OK
button you switch to the next
menu item.
Revalue bonus step
1:
0.0 EUR
The revalue bonus step 1 offers the possibility, to set a certain
revalue amount, which the chip card type 11 is re-valued with
an extra bonus to the value of the revalue bonus amount 1.The
revalue bonus step can be set in steps of 0.1 from 0.0 to 999.9.
With the
RESET
and
PLUS
button the values can be altered,
with the
OK
button you switch to the next menu item.
The revalue bonus steps must be programmed in an in
creasing sequence that means, the revalue bonus step 1
must be smaller than revalue bonus step 2 etc. When 5
revalue bonuses are not required, the ones which are not
used can be set at 0.0, then they are deactivated.
The particular revalue bonus amount is automatically
suspended.
Revalue bonus
amount
1:
0.0 EUR
The revalue bonus step 1 offers the possibility, to set a certain
revalue amount, which the chip card type 11 is revalued with an
extra bonus to the value of the revalue bonus amount 1.The re-
value bonus step can be set in steps of 0.1 from 0.0 to 999.9.
With the
RESET
and
PLUS
the values can be changed by the
OK
button you switch to the next menu item.
The revalue bonus amount must be programmed in an in-
creasing sequence that means, the revalue bonus amount
1 must be smaller than revalue bonus amount 2 etc.
Revalue bonus step 2-5 0.0 EUR
Analogue revalue bonus step 1
Revalue bonus step 2-5 0.0 EUR
Analogue revalue bonus step 1