background image

Page 5

TYPE 6.2.0.7-RF

Programming the Essex Keypad

Note

: If the User ID, or User Code/PIN has already been assigned, you will hear one long beep when #  is  entered.   In

this case, choose a different User ID /  PIN, or see the instructions for changing or deleting codes. 

DEFAULT USER CODE & MASTER CODE IS “123#’’

        1            

The default Master Code is

“123”

.                                                                                                                                               

This can be changed to a unique code 3 - 8 digits long

        2            Enter

*

3 1 2 3 #

                                                                                                      Double Beep      Fast Flash

Solid

        3            Enter 

#

                                                                                                                   Double Beep      Fast Flash

Slow Flash

        4            Enter new master code, followed by

#

                                                                      Triple Beep         Fast Flash

Solid

        5            Enter 

* *

                                                                                                                   Double Beep

        6            EXAMPLE:  old code is 123, new code is 456    

3 1 2 3 # 1 # 4 5 6 # 

* *

Set Master Code

STEP       ACTION                                                                             BEEP          Red LED

Green LED

        1            Remove power 

        2            Jumper the “CONFIG”  pins on the rear of the keypad  .     V = 12

        3            Apply 12 VDC power to red and black wires                                                              Quadruple Beep     Flash       

Solid

        4            Enter 

9 9

followed by

#

                                                                                             Double Beep          Flash                   Solid   

        5            Enter  

2 1 4

followed by

#

                                                                                       Triple Beep            Flash

Solid

        6            Remove power

        7            Remove “CONFIG” jumper

        8            Reapply  power

  STEP    ACTION                                                                            BEEP          Red LED

Green LED

Set Keypad Illumination to 

ON ALL OF THE TIME

Содержание 400-S12-TES2

Страница 1: ...y an swering any of the ringing phones in the House TES2 is a 2 door system front door back door Access Control Essex stand alone 12 button keypad 1 relay plus 2 grounding outputs external relays requ...

Страница 2: ...for DC voltage to strike Remote Bypass Button Gate Strike DC Out for Strike 12 Volt 12 Volt No Ring Jumper House Telephones NOTE Voltage from telephones is not necessary for the system to work See not...

Страница 3: ...ecessary for the system to work See note No CO operation The connection between the main board and the speaker board is polarity sensitive CO Line In To House Phones Door 2 Door 1 T1 R1 T2 R2 No Co Ju...

Страница 4: ...hones is not necessary for the system to work See note No CO operation The connection between the main board and the speaker board is polarity sensitive CO Line In To House Phones Door 2 Door 1 T1 R1...

Страница 5: ...Solid 3 Enter 1 Double Beep Fast Flash Slow Flash 4 Enter new master code followed by Triple Beep Fast Flash Solid 5 Enter Double Beep 6 EXAMPLE old code is 123 new code is 456 3 1 2 3 1 4 5 6 Set Ma...

Страница 6: ...Triple Beep Slow Flash Slow Flash 10 Enter Double Beep X 2 Set User Codes STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step Master Code 123 is used as an example 2 Ente...

Страница 7: ...e programming Triple Beep Slow Flash Slow Flash 7 Enter Double Beep X 2 Deleting User Codes using User Code PIN STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step In thi...

Страница 8: ...Double Beep Slow Flash Slow Flash 4 Enter the desired activation time in Seconds followed by Triple Beep Slow Flash Solid 5 Enter to exit 6 Example 2 10 10 second activation time Setting Main Relay O...

Страница 9: ...on would be used if the homeowners used cell phone only no house phone line In this case several phones would be required throughout the house These phones would be used only for answering door phone...

Страница 10: ...ilt in call waiting If the house phone is in use when the door button is pushed the caller will receive a call waiting tone To answer the door call simply flash to answer the door call and flash again...

Отзывы: