Programming the Essex Keypad

Note

: If the User ID, or User Code/PIN has not been assigned, you will hear one long beep 

when #  is entered.  

Reset Keypad to Factory Defaults--- This is not normally necessary, but can be done as follows

STEP

ACTION                                                                     BEEP          Red LED

Green LED

1

The default Master Code is “123”

.

This can be changed to a unique code  3 - 8 digits long.

2

Enter 

*3 1 2 3

#

Double Beep          Slow Flash         Solid

3

Enter 

#

Double Beep          Slow Flash

Slow Flash

4

Enter the desired activation time in 

Seconds

followed by 

#

Triple Beep            Slow Flash

Solid

5

Enter 

* *

to exit

6

Example:

2 # 10 # 

* *

(10 second activation time)

Setting Main Relay Opening Time

STEP

ACTION                                                                     BEEP          Red LED

Green LED

1

Remove power 

2

Jumper the “CONFIG”  pins on the rear of the keypad

3

Apply 12 VDC power to red and black wires ONLY

Quadruple Beep       Flash                      Solid

5

Enter 

0 0 9 9 

#

Double Beep             Flash

3 Sec Flash

6

WAIT about 4 seconds

Quadruple Beep        Flash                      Solid

7

Enter 

9 9 

#

Triple Beep                Flash 

Solid

8

Remove power

9

Remove “CONFIG” jumper

10

Reapply  power

Page 7

TyPE 6.2.0.8-RF

Содержание 400-S12-PAN2

Страница 1: ...er supply included INSTALLATION INSTRUCTIONS 501 E Goetz Ave Santa Ana Ca 92707 www eholovision com Ph 714 434 6904 Fax 800 362 0002 HOLOVISION Not Used 12 VDC input for camera and keypad NO COM NC re...

Страница 2: ...ack which can be created when power is removed from the strike Loop is required from 12v positive to contact common for DC power to strike Essex Keypad Wiring DC Out for Gate Strike Page 2 Type 6 2 0...

Страница 3: ...Contact Closure for Gate Operation Page 3 Type 6 2 0 8 RF To Phones Refer to manual pages 6 8 for details Cut for NO Contact Closure AC Loop for Strike Gate Motor PAN 2 9V DC NOTE This connection is...

Страница 4: ...Beep Fast Flash Slow Flash 4 Enter new master code followed by Triple Beep Fast Flash Solid 5 Enter Double Beep 6 EXAMPLE old code is 123 new code is 456 3 1 2 3 1 4 5 6 Set Master Code STEP ACTION B...

Страница 5: ...Triple Beep Slow Flash Slow Flash 10 Enter Double Beep X 2 Set User Codes STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step Master Code 123 is used as an example 2 Ente...

Страница 6: ...e programming Triple Beep Slow Flash Slow Flash 7 Enter Double Beep X 2 Deleting User Codes using User Code PIN STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step In thi...

Страница 7: ...Double Beep Slow Flash Slow Flash 4 Enter the desired activation time in Seconds followed by Triple Beep Slow Flash Solid 5 Enter to exit 6 Example 2 10 10 second activation time Setting Main Relay O...

Страница 8: ...501 E Goetz Ave Santa Ana Ca 92707 Ph 714 434 6904 Fax 800 362 0002 www eholovision com...

Отзывы: