background image

Manual Type 6.2.0.8-RF

Paasonic KX-T7775 Intercom with Essex 

“S-12 Stand - Alone” Keypad

For Models

400-S12-PAN2    401-S12-PAN2 
403-S12-PAN2    404-S12-PAN2
410-S12-PAN2    411-S12-PAN2 

Specifications

Access Control

Essex “stand-alone” 12 button keypad
1 relay plus 2 grounding outputs 
(external relays required)
500 users
12 VDC power supply included

INSTALLATION

INSTRUCTIONS

501 E. Goetz Ave.

Santa Ana, Ca 92707

www.eholovision.com

Ph. 714-434-6904

Fax 800-362-0002

HOLOVISION

Not Used

12 VDC input (for camera and keypad)

NO, COM, NC relay connections

Keypad case ground

Remote bypass terminals (activate relay)

Connect tamper switch to alarm (optional)

Intercom to PAN-2 Module

Communication

For use with all Panasonic KSUs with door phone
card. This unit is a replacement for the Panasonic
KXT-7775 door phone. 

Cut for NO Contact Closure

AC Loop for Strike

Содержание 400-S12-PAN2

Страница 1: ...er supply included INSTALLATION INSTRUCTIONS 501 E Goetz Ave Santa Ana Ca 92707 www eholovision com Ph 714 434 6904 Fax 800 362 0002 HOLOVISION Not Used 12 VDC input for camera and keypad NO COM NC re...

Страница 2: ...ack which can be created when power is removed from the strike Loop is required from 12v positive to contact common for DC power to strike Essex Keypad Wiring DC Out for Gate Strike Page 2 Type 6 2 0...

Страница 3: ...Contact Closure for Gate Operation Page 3 Type 6 2 0 8 RF To Phones Refer to manual pages 6 8 for details Cut for NO Contact Closure AC Loop for Strike Gate Motor PAN 2 9V DC NOTE This connection is...

Страница 4: ...Beep Fast Flash Slow Flash 4 Enter new master code followed by Triple Beep Fast Flash Solid 5 Enter Double Beep 6 EXAMPLE old code is 123 new code is 456 3 1 2 3 1 4 5 6 Set Master Code STEP ACTION B...

Страница 5: ...Triple Beep Slow Flash Slow Flash 10 Enter Double Beep X 2 Set User Codes STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step Master Code 123 is used as an example 2 Ente...

Страница 6: ...e programming Triple Beep Slow Flash Slow Flash 7 Enter Double Beep X 2 Deleting User Codes using User Code PIN STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step In thi...

Страница 7: ...Double Beep Slow Flash Slow Flash 4 Enter the desired activation time in Seconds followed by Triple Beep Slow Flash Solid 5 Enter to exit 6 Example 2 10 10 second activation time Setting Main Relay O...

Страница 8: ...501 E Goetz Ave Santa Ana Ca 92707 Ph 714 434 6904 Fax 800 362 0002 www eholovision com...

Отзывы: