background image

Page 8

TYPE 

1.1.0.9-RF

VIO RAVA Quick Start

1.  Plug the device into the network. Device will speak it’s IP address.

2.  Navigate to device IP on a web browser.

3.  Under “Configuration” please enter SIP ID for the name to be displayed, and enter the extension

of the Main RAVA Touchscreenunder “

Input Call ID 0 Default is CALL:CRESTRON”

*Note out of the box the “CALL:CRESTRON” default will ring all touchpanels in the CRESTRON

call group.  

4.  Configure the Audio setiings. 

Note:RAVA Operation has been designated to “Push to Talk” (PTT)

from Crestron and only this operation will be supported.

Although full duplex and half duplex

are an option, these settingdo not perform best in all senarios. As a recommendation you can 

experiment for the best audio settings.

AUDIO SETTING BELOW ARE ONLY A RECOMMENDATION

Содержание 201-VIO

Страница 1: ...sex 5 button keypad 2 relays 5 6 users 16 5 VAC power supply included Internal rectifier gives optional dc out for strikes For Models 201 VIO 203 VIO 301 VIO 302 VIO Communication Holovision VIO is a...

Страница 2: ...ated when power is removed from the strike Page 2 TYPE 1 1 0 9 RF Essex Model 265 NC 2 NO 2 COM 2 NC 1 NO 1 COM 1 DC OUT AC IN Remote Monitor Earth Holovision Entry System with Keypad Keypad cable 22...

Страница 3: ...rom the strike Page 3 TYPE 1 1 0 9 RF NOTE Jumper Wire is Required Essex Model 265 NC 2 NO 2 COM 2 NC 1 NO 1 COM 1 DC OUT AC IN Remote Monitor Earth Holovision Entry System with Keypad Keypad cable 22...

Страница 4: ...ch CCTV Doorbell Relay 1 Relay 2 Step Action 2 Relay 1 and 2 activate and latch Code Relay 1 Relay 2 Open Latch Open Latch Master Code No No No No Code 1 2 Yes Yes No No Code 3 4 5 No No Yes Yes o o o...

Страница 5: ...is pressed you have 2 minutes to complete Step 5 3 Press 1119 you will hear 3 beeps 4 Step 5 must be completed within 5 seconds of Step 3 5 Enter Master Code 6 Wait 5 seconds for 3 beeps to confirm n...

Страница 6: ...s for 3 reset beeps Delete Any Code Step Action Note User codes can be 3 to 8 digits Page 6 TYPE 1 1 0 RF 1 Enter any User Code 1 5 2 Enter 7 This will cause the relay to latch subject to the jumper p...

Страница 7: ...1 8 seconds 5 1 1 1 12 seconds 5 5 1 1 4 Wait 5 seconds for 4 reset beeps Set Activation Time Of Relay 2 User codes 3 4 5 see note below Step Action Note The above 2 steps are actually setting the act...

Страница 8: ...ll ID 0 Default is CALL CRESTRON Note out of the box the CALL CRESTRON default will ring all touchpanels in the CRESTRON call group 4 Configure the Audio setiings Note RAVA Operation has been designat...

Страница 9: ...Calls Configure the powered relay and the dry contact closure Choose any 2 to 4 digit combination Note By configuring the request to exit feature you can configure for either relay 6 Once the device h...

Страница 10: ......

Страница 11: ......

Страница 12: ...501 E Goetz Ave Santa Ana Ca 92707 Ph 714 434 6904 Fax 800 362 0002 www eholovision com...

Отзывы: