background image

Programming of Essex Keypad

        1            Press “Program” switch (keypad will beep 4 times).

        2            Enter 1115 (3 beeps).

        3            Enter 1 for every 1 second  latch time, and 5 for every 5 seconds.

                      Examples:

                      

6 seconds = 5, 1

                      

8 seconds = 5, 1, 1, 1

                      

12 seconds = 5, 5, 1, 1

        4            Wait 5 seconds for 4 reset beeps.

Set Activation Time Of Relay 2 (User codes 3, 4& 5 - see note below)

  Step                                                     Action

Note: The above 2 steps are actually setting the activation times for user code 1, 2 and user code 3, 4, 5.  Using the

jumper pin setting as shown in “Set Essex Relay Options”, this will set activation time of Relays 1 & 2.

Page 7

TYPE 

1.1.0.9-RF

Содержание 201-VIO

Страница 1: ...sex 5 button keypad 2 relays 5 6 users 16 5 VAC power supply included Internal rectifier gives optional dc out for strikes For Models 201 VIO 203 VIO 301 VIO 302 VIO Communication Holovision VIO is a...

Страница 2: ...ated when power is removed from the strike Page 2 TYPE 1 1 0 9 RF Essex Model 265 NC 2 NO 2 COM 2 NC 1 NO 1 COM 1 DC OUT AC IN Remote Monitor Earth Holovision Entry System with Keypad Keypad cable 22...

Страница 3: ...rom the strike Page 3 TYPE 1 1 0 9 RF NOTE Jumper Wire is Required Essex Model 265 NC 2 NO 2 COM 2 NC 1 NO 1 COM 1 DC OUT AC IN Remote Monitor Earth Holovision Entry System with Keypad Keypad cable 22...

Страница 4: ...ch CCTV Doorbell Relay 1 Relay 2 Step Action 2 Relay 1 and 2 activate and latch Code Relay 1 Relay 2 Open Latch Open Latch Master Code No No No No Code 1 2 Yes Yes No No Code 3 4 5 No No Yes Yes o o o...

Страница 5: ...is pressed you have 2 minutes to complete Step 5 3 Press 1119 you will hear 3 beeps 4 Step 5 must be completed within 5 seconds of Step 3 5 Enter Master Code 6 Wait 5 seconds for 3 beeps to confirm n...

Страница 6: ...s for 3 reset beeps Delete Any Code Step Action Note User codes can be 3 to 8 digits Page 6 TYPE 1 1 0 RF 1 Enter any User Code 1 5 2 Enter 7 This will cause the relay to latch subject to the jumper p...

Страница 7: ...1 8 seconds 5 1 1 1 12 seconds 5 5 1 1 4 Wait 5 seconds for 4 reset beeps Set Activation Time Of Relay 2 User codes 3 4 5 see note below Step Action Note The above 2 steps are actually setting the act...

Страница 8: ...ll ID 0 Default is CALL CRESTRON Note out of the box the CALL CRESTRON default will ring all touchpanels in the CRESTRON call group 4 Configure the Audio setiings Note RAVA Operation has been designat...

Страница 9: ...Calls Configure the powered relay and the dry contact closure Choose any 2 to 4 digit combination Note By configuring the request to exit feature you can configure for either relay 6 Once the device h...

Страница 10: ......

Страница 11: ......

Страница 12: ...501 E Goetz Ave Santa Ana Ca 92707 Ph 714 434 6904 Fax 800 362 0002 www eholovision com...

Отзывы: