After immersion
If a Holmatro Certified Technician can not clean the tool within 1 week, do these temporary maintenance
steps that follow. The Holmatro Certified Technician must clean the tool subsequently.
1. Remove the battery pack. Flush the tool, battery pack and accessories with fresh, clean water.
2. If the tool has been used in muddy or dirty water, the c
overs
must be removed to remove residual
dirt.
Refer to Fig. 14
i
Remove the screws (A, 8x) from the upper c
over
.
ii
Remove the upper c
over
(B). Do not disconnect wiring.
iii
Remove the crews (C, 6x) from the bottom c
over
s.
iv
Remove the bottom c
over
s (D, 2x).
3. Flush the inner parts with fresh clean water and remove residual dirt and contamination.
4. Lubricate all exposed steel parts with a rust inhibitor and moisture repellant.
5. Let the tool, battery and accessories dry in the air at room temperature.
6. Install the c
over
s.
7. Store the tool in a dry and well-ventilated area.
Additional steps if the tool does not respond to the control handle after immersion.
If the motor keeps running, clean the control sensors inside the control handle.
1. Refer to Fig. 15
i
The upper c
over
must be removed (A, 8x) (B). Do not disconnect wiring.
ii
Remove the crews from the control handle ring (C, 5x).
iii
Remove the control handle ring (D). Do not disconnect wiring.
iv
Open the dust cap (E).
v
Remove the lock ring (F).
vi
Remove the control handle (G).
2. Flush the control sensors (H, 2x) with fresh clean water and remove remaining dirt and
contamination.
3. Lubricate all exposed steel parts with a rust inhibitor and moisture repellant.
4. Let the tool dry in the air at room temperature.
5. Install the parts.
6. Store the tool in a dry and well-ventilated area.
7
Troubleshooting
7.1
General
Consult the Holmatro dealer if the listed solutions do not give the desired result, or in case of other
problems. For malfunctions or repair, always specify the model and serial number of the equipment.
NOTICE
If the battery pack has to be returned to the dealer for repairs, make sure that the battery
pack is packaged according to the specific instructions applicable for Li-Ion battery packs.
See section 8.7.
Содержание PCU50
Страница 1: ... i PCU50 Handleiding NL Manual EN Mode d emploi FR Betriebsanleitung DE Manual ES Manual PT 手册 ZH ...
Страница 3: ...PCU50 916 400 096_003 3 Fig 1 Fig 2 ...
Страница 4: ...4 916 400 096_003 PCU50 Fig 3 Fig 4 Fig 5 ...
Страница 173: ...PCU50 916 400 096_003 173 i Fig 6 Fig 7 ...
Страница 174: ...174 916 400 096_003 PCU50 Fig 8 Fig 9 Fig 10 Fig 11 90 C A A B ...
Страница 176: ...176 916 400 096_003 PCU50 i Fig 14 Fig 15 ...