15
8.4 The connected equipment is not operating - or not
properly.
1
Check the pump hydraulic oil
level.
No or low
hydraulic fluid
Add recommended
hydraulic fluid up
correct level.
Hydraulic fluid level correct
2
Twin-line
: Check the coupler
connections.
---------------------------------------
Core
: Check the coupler
connections.
Incorrect or
incomplete
coupling.
Release pressure at
pump and reconnect.
--------------------------
Reconnect couplings
Couplings correct
3
Twin-line:
Check the position of
the pump pressure relief valve.
---------------------------------------
Core™:
Check the pump valve
block relief valve stem.
Valve in Neutral
position.
----------------------
Valve stem is all
the way in
Turn valve to
“OPERATION”.
--------------------------
Turn valve stem all the
way out
.
Valve position okay
4
Consult your Holmatro Dealer
8.5 The dead-man’s handle is not operating properly.
1
Check control handle for external
damage
Control handle
damaged
Contact your
Holmatro Dealer
Control handle okay
2
Check if the dead-man handle is
stuck in any position. The
control handle should move
freely.
Dead-man handle
stuck
Contact your
Holmatro Dealer
Dead-man handle okay.
3
Consult your Holmatro Dealer