PAGE 11

Manual Operations

Run A Single Station

The maximum Run time for a station is 12 hours 59
minutes. To manually run a single station once,

 turn

 the

dial to 

Run Single Station

 position and the display will

show:

To adjust the Run Time, use the 

 button and to advance

to the next station 

press

 the 

next

 button.

System Test Facility

This feature can be used to test that your valves and
sprinklers are working correctly. 

Turn 

the dial to 

Run Test

Cycle

 

and the diplay will show:

The controller will run through all stations for 2 minutes in
sequential order while you go and check your sprinklers.

Note: The system test facility is preset at 2 minutes per

station and can be adjusted using 

 or 

 .

Run A Program

To manually run a complete program once for the run
times as set in the automatic schedule. 

Turn

 the dial to

the 

Run Program

 position. “Prog 1” will be shown in the

display. To run program 1, leave or advance to program 2
by 

pressing

 

next

 .

Programming

Step 3. Set Station Run Times. 

(Continued)

To adjust the 

Run time 

in minutes 

press

 

next

, and use

 or 

 . To set the run time in hours, 

press

 

next

 and “0”

will appear and flash. To adjust use 

 or 

. If not

required press 

next

 

and advance to station 2 by pressing

the 

 button.

Continue until all the stations in Program1 have been set
with a run time or if a station (or stations) is not required
to be active in this particular program, ensure that the
Run time is set to “OFF”.

Note: To set a station to 

“OFF”

. Use 

 when the 

“RUN

TIME” 

is flashing.

This completes the setting up procedure for automatic
watering of Program 1.

Should you need the second program to have an
automatic schedule, 

turn

 the dial to “Set Start times” and

“Prog 1” will flash. press 

 and change to program 2

position and follow the same 3 steps for automatic
watering.

1. Set Starts

2. Set Watering Days

3. Set Station Run Times

Tip: Remember to return the dial to the “Auto Run”
position at the completion of the setting up of the
automatic schedules. This will ensure that the automatic
cycles will take place.

PAGE 10

Содержание dial ezy 4

Страница 1: ...INSTRUCTION MANUAL SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID 4 6 OR 8 STATION MODELS IRRIGATION CONTROLLER ...

Страница 2: ... per program or a 365 calendar for Odd Even day watering or selectable interval watering schedules from everyday to every 15th day A key feature of this controller is the water saver feature which allows quick adjustment of the station watering times by percentages as the seasons change Features Features 1 Glossary 2 Programming Instructions Introduction 3 Other Functions 4 General tips for progra...

Страница 3: ... are watering similar garden areas together Examples Turf flower beds pergola areas vegetables These different groups may require individual watering schedules l Plan your watering schedule and write the information on the planner supplied at the back of this book l Set the current time and correct day of the week l Set the automatic program for each group by completing the following 3 steps 1 Set...

Страница 4: ...ning A test facility for checking the valves and sprinklers is also provided General tips for easy programming Tips to help eliminate programming confusion l Complete the spare watering planner l When setting one push of the button will increment one unit l Holding one button down will fast scroll through units l During programming flashing units are able to be set using or buttons l Pressing next...

Страница 5: ... active start time off turn the dial to the Set Start times position Select the start number required using the button and then press next until the hour is flashing Use or until OFF is shown Tip OFF position is between 12 and 1 Programming Programming Set Current Time Correct Day Turn the dial to Set Clock Calendar position The hour will be flashing Use or to adjust Note AM PM must be set correct...

Страница 6: ...how the following This means station 1 has a default run time of 10 minutes in program 1 Station 1 will be flashing Programming Step 2 Set Watering Days This unit has interval watering or individual day selection from everyday to every 15th day or a 365 day calendar with odd even day selection in areas where water restrictions require this feature Turn the dial to Set Watering Days Interval Day Se...

Страница 7: ... advance to program 2 by pressing next Programming Step 3 Set Station Run Times Continued To adjust the Run time in minutes press next and use or To set the run time in hours press next and 0 will appear and flash To adjust use or If not required press next and advance to station 2 by pressing the button Continue until all the stations in Program1 have been set with a run time or if a station or s...

Страница 8: ...anual watering schedule turn the dial to the Off position Tip for automatic watering remember to turn the dial back to the Auto Run position as the Off position will stop any watering cycles from occuring Stacking Start Times Should you accidently set the same watering start time on more than one program the Controller will stack them in sequential order from the lowest number All programmed start...

Страница 9: ...re maintenance work to controller or valves and when connecting and disconnecting field wiring and pump or master valve hook ups Other Features Rain Off Mode To stop the automatic watering cycles during winter turn the dial to the Off position The word Off will appear in the display This means the automatic schedules will not come on but the programmed information is still retained in the memory T...

Страница 10: ...1 Prepare wires for hook up by cutting the wires to the correct length and stripping approximately 6 0mm inch of insulation from the end to be connected to the controller 2 Ensure terminal block screws are loosened sufficiently to permit easy access for wire ends Insert stripped wire ends into the clamp aperture and tighten screws Do not over tighten as this may damage the terminal block 3 A maxim...

Страница 11: ...Overload protection Standard 20mm 1 Amp fuse l Power failure 9 Volt block type battery maintains clock and programs for up to 4 weeks l The output circuits should be installed and protected in accordance with wiring rules Installation Instructions Pump Hook Up Connections Do not attempt to drive a pump starter directly from the controller Pump start is provided by connecting one side of the coil o...

Страница 12: ...still not responding return panel to supplier or manufacturer Check number of start times entered on each program If programming is correct return panel to supplier or manufacturer Check wiring and swap faulty station wire s on controller terminal block with known working station wire If the same outputs are still locked on return panel to supplier or manufacturer Electrician to check voltage on p...

Страница 13: ...TERING PROGRAM NO STATION WATERING DURATION WATERING START TIME S GARDEN AREA STN NO 1 2 3 4 5 6 7 8 PAGE 22 Spare Watering Planner FREQUENCY OF WATERING PROGRAM NO STATION WATERING DURATION WATERING START TIME S GARDEN AREA STN NO 1 2 3 4 5 6 7 8 ...

Страница 14: ...TERING PROGRAM NO STATION WATERING DURATION WATERING START TIME S GARDEN AREA STN NO 1 2 3 4 5 6 7 8 PAGE 24 Spare Watering Planner FREQUENCY OF WATERING PROGRAM NO STATION WATERING DURATION WATERING START TIME S GARDEN AREA STN NO 1 2 3 4 5 6 7 8 ...

Страница 15: ...of which this product is part The guarantee shall not apply to any equipment which is found to have been improperly installed set up or used in any way not in accordance with the instructions supplied with this equipment or to have been modified repaired or altered in any way without the express written consent of the company This guarantee shall not apply to any batteries or accessories used in t...

Отзывы: