background image

Possible Cause

Faulty transformer.

Fuse blown.

Faulty solenoid coil.

Incorrect wiring or bad
wiring joint.

Incorrect
programming or blown
fuse.

Short on keypad or
Programming not
correct.

Short on keypad or
too many start times
entered on automatic
programs.

Damaged main output
driver chip.

Faulty relay or pump
contactor.

Display damaged
during transportation.

Fault Finding Guide

Symptom

No display.

Single Station
not working.

Fuse blows.

No automatic
start.

Buttons on
keypad not
responding.

System
coming on at
random.

More than 1
station coming
on at once.

Pump start
chattering.

Display
cracked or
missing
segments.

Suggestion

Check fuse. Check field wiring.
Check transformer.

Swap faulty station wire on
controller terminal block with
known working station wire.  If
the faulty valve still does not
work on the known working
connection then the solenoid coil
is faulty. The panel may need to
be repaired.

Check wiring and joints.

If unit works manually check
programming. Check fuse and
field wiring.

Check instruction book to ensure
programming correct. If keypad
still not responding return panel to
supplier or manufacturer.

Check number of start times
entered on each program. If
programming is correct return
panel to supplier or manufacturer.

Check wiring and swap faulty
station wire(s) on controller
terminal block with known working
station wire. If the same outputs
are still locked on, return panel to
supplier or manufacturer.

Electrician to check voltage on
pump relay or contactor.

Return panel to supplier or
manufacturer.

PAGE 21

Follow these steps:

1

Turn Mains power off to the controller.

2

Disconnect 24 Volt power leads from the PLUG PACK
at the controller 24VAC terminals.

3

Clearly mark or identify all valve wires according to the
terminals they are connected to, (1 to 8). This allows
you to easily wire them back to the Controller,
maintaining your valve watering sequence.

4

Disconnect valve wires from the terminal block.

5

Remove the complete unit from the wall.

6

Carefully wrap the complete unit in protective
wrapping and pack in a suitable box. Return to your
service agent or the manufacturer.

Note

: Tampering with the unit will cancel the

Guarantee

7

Replace your controller by reversing this procedure.

Servicing The Controller

The Controller should always be serviced by an
authorized agent.

PAGE 20

Содержание dial ezy 4

Страница 1: ...INSTRUCTION MANUAL SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID 4 6 OR 8 STATION MODELS IRRIGATION CONTROLLER ...

Страница 2: ... per program or a 365 calendar for Odd Even day watering or selectable interval watering schedules from everyday to every 15th day A key feature of this controller is the water saver feature which allows quick adjustment of the station watering times by percentages as the seasons change Features Features 1 Glossary 2 Programming Instructions Introduction 3 Other Functions 4 General tips for progra...

Страница 3: ... are watering similar garden areas together Examples Turf flower beds pergola areas vegetables These different groups may require individual watering schedules l Plan your watering schedule and write the information on the planner supplied at the back of this book l Set the current time and correct day of the week l Set the automatic program for each group by completing the following 3 steps 1 Set...

Страница 4: ...ning A test facility for checking the valves and sprinklers is also provided General tips for easy programming Tips to help eliminate programming confusion l Complete the spare watering planner l When setting one push of the button will increment one unit l Holding one button down will fast scroll through units l During programming flashing units are able to be set using or buttons l Pressing next...

Страница 5: ... active start time off turn the dial to the Set Start times position Select the start number required using the button and then press next until the hour is flashing Use or until OFF is shown Tip OFF position is between 12 and 1 Programming Programming Set Current Time Correct Day Turn the dial to Set Clock Calendar position The hour will be flashing Use or to adjust Note AM PM must be set correct...

Страница 6: ...how the following This means station 1 has a default run time of 10 minutes in program 1 Station 1 will be flashing Programming Step 2 Set Watering Days This unit has interval watering or individual day selection from everyday to every 15th day or a 365 day calendar with odd even day selection in areas where water restrictions require this feature Turn the dial to Set Watering Days Interval Day Se...

Страница 7: ... advance to program 2 by pressing next Programming Step 3 Set Station Run Times Continued To adjust the Run time in minutes press next and use or To set the run time in hours press next and 0 will appear and flash To adjust use or If not required press next and advance to station 2 by pressing the button Continue until all the stations in Program1 have been set with a run time or if a station or s...

Страница 8: ...anual watering schedule turn the dial to the Off position Tip for automatic watering remember to turn the dial back to the Auto Run position as the Off position will stop any watering cycles from occuring Stacking Start Times Should you accidently set the same watering start time on more than one program the Controller will stack them in sequential order from the lowest number All programmed start...

Страница 9: ...re maintenance work to controller or valves and when connecting and disconnecting field wiring and pump or master valve hook ups Other Features Rain Off Mode To stop the automatic watering cycles during winter turn the dial to the Off position The word Off will appear in the display This means the automatic schedules will not come on but the programmed information is still retained in the memory T...

Страница 10: ...1 Prepare wires for hook up by cutting the wires to the correct length and stripping approximately 6 0mm inch of insulation from the end to be connected to the controller 2 Ensure terminal block screws are loosened sufficiently to permit easy access for wire ends Insert stripped wire ends into the clamp aperture and tighten screws Do not over tighten as this may damage the terminal block 3 A maxim...

Страница 11: ...Overload protection Standard 20mm 1 Amp fuse l Power failure 9 Volt block type battery maintains clock and programs for up to 4 weeks l The output circuits should be installed and protected in accordance with wiring rules Installation Instructions Pump Hook Up Connections Do not attempt to drive a pump starter directly from the controller Pump start is provided by connecting one side of the coil o...

Страница 12: ...still not responding return panel to supplier or manufacturer Check number of start times entered on each program If programming is correct return panel to supplier or manufacturer Check wiring and swap faulty station wire s on controller terminal block with known working station wire If the same outputs are still locked on return panel to supplier or manufacturer Electrician to check voltage on p...

Страница 13: ...TERING PROGRAM NO STATION WATERING DURATION WATERING START TIME S GARDEN AREA STN NO 1 2 3 4 5 6 7 8 PAGE 22 Spare Watering Planner FREQUENCY OF WATERING PROGRAM NO STATION WATERING DURATION WATERING START TIME S GARDEN AREA STN NO 1 2 3 4 5 6 7 8 ...

Страница 14: ...TERING PROGRAM NO STATION WATERING DURATION WATERING START TIME S GARDEN AREA STN NO 1 2 3 4 5 6 7 8 PAGE 24 Spare Watering Planner FREQUENCY OF WATERING PROGRAM NO STATION WATERING DURATION WATERING START TIME S GARDEN AREA STN NO 1 2 3 4 5 6 7 8 ...

Страница 15: ...of which this product is part The guarantee shall not apply to any equipment which is found to have been improperly installed set up or used in any way not in accordance with the instructions supplied with this equipment or to have been modified repaired or altered in any way without the express written consent of the company This guarantee shall not apply to any batteries or accessories used in t...

Отзывы: