Doc. 12-4091 - r01 (9/12/12)
PG-58
SERVICE
GUIDE
SUPPORT: TOLL-FREE 888-383-DIVE │ FAX 510-729-5115 │ E-MAIL [email protected]
©
2002 DESIGN
(
2012)
REASSEMBLY
NOTE: If the INTERNAL OVER-PRESSURE PLUG
(2) was still intact upon BATTERY HOUSING (1)
disassembly, skip step 1.
1. Ensure the plastic sealing surface is not damaged.
Then press the new
O-RING (3)
and
OVER-PRESSURE
PLUG (2)
into the port until fully seated with a dull instru-
ment (dental tool)
(Fig. 6)
.
2. Plug the
BATTERY CABLE ASSEMBLY (8)
into the
BULKHEAD CONNECTOR (7)
.
3. Fit the
FOAM INSERT (9)
into the
HOUSING (1)
.
4. Connect new batteries to the
BATTERY CABLE
ASSEMBLY (8)
. Then, ensuring that the wiring is not
twisted or contorted, place the batteries into the cutout in
the
FOAM INSERT (9)
.
NOTE: If the PRESSURE RELIEF VALVE (13) on
the LID (12) was not removed for replacement,
skip step 5.
5. Using a torque driver and 12 mm socket, tighten the
PRESSURE RELIEF VALVE ASSEMBLY (13)
clockwise
to a torque of 35 to 40 in/lbs (4 to 4.5 N-m)
(Fig. 7)
.
DO
NOT
over-tighten.
6. Lightly lubricate and seat the
COMPARTMENT O-
RING (10)
in the groove of the
HOUSING (1)
, as shown
(Fig. 8)
.
7. Lightly lubricate and seat the
LID O-RING (11)
in the
groove of the
BATTERY LID (12)
, as shown.
8. Align the tabs of the
BATTERY LID (12)
. Then press
the
LID (12)
in place.
9. Engage and latch the two
RETAINING LATCHES (5)
(FIG. 9)
.
Fig. 6