Doc. 12-4091 - r01 (9/12/12)
PG-10
SERVICE
GUIDE
SUPPORT: TOLL-FREE 888-383-DIVE │ FAX 510-729-5115 │ E-MAIL [email protected]
©
2002 DESIGN
(
2012)
• To help avoid any confusion during Disassembly, those parts that are not to be replaced automatically should be
Inspected after Disassembly is completed. They should be laid out in the order they are removed, and compared
with identical new parts to better discern their condition before Reassembly is performed.
• O-rings should be Inspected using a magnifier to ensure they are supple, well rounded, and completely free of
any scoring or corrosion that would impair proper sealing. Replace any O-rings in questionable condition.
CLEANING AND LUBRICATION:
TOOLS AND CLEANING SUPPLIES
• Tools to be used must be clean and free of contaminates such as dirt, dust, silicone grease, and oil.
• A supply of warm to hot clean fresh water will be needed for rinsing.
• For blow drying parts and components, a clean (oil free) low pressure air supply is to be used.
DISASSEMBLY
• Again, prior to beginning Disassembly perform the Inspection and Troubleshooting Procedures at the beginning
of each of this Guide's sections.
• Disassemble the different PRISM 2 components in accordance with the disassembly section provided in this
Service Procedure Guide.
CLEANING TIPS
CAUTION: DO NOT use a metal wire brush.
WARNING: If salt or grit is found on any O-rings, discard them and replace with new ones. DO NOT at-
tempt to reuse them.
• Prior to Cleaning, carefully remove any existing thread locking residue from the Threads using a brass or plastic
dental instrument.
• During Cleaning, use special care not to damage Components such as those with delicate Seating Surfaces.
CLEANING - GENERAL
Plastic or Rubber Parts
• Reusable soft and hard Parts, such as regulator Spacers and Protector Caps may be soaked and cleaned in a
solution of warm water mixed with mild dish soap.
• To scrub away deposits, use only a soft nylon toothbrush.